Evaluation on fire resistance of composite segmental lining for shield tunnel

被引:9
|
作者
Zhang, Gaole [1 ,2 ]
Zhang, Wenjun [1 ,2 ,6 ]
Zhang, Xinxin [3 ]
Shangguan, Dandan [2 ]
Ling, Tonghua [4 ]
Guan, Linxing [5 ]
机构
[1] Guangxi Univ, Sch Civil Engn & Architecture, Nanning 530004, Guangxi, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin 300350, Peoples R China
[3] China United Engn Corp Ltd, Hangzhou 310000, Peoples R China
[4] Changsha Univ Sci & Technol, Sch Civil Engn, Changsha 410004, Peoples R China
[5] Shanghai Municipal Engn Design Inst Grp Co Ltd, Shanghai 200092, Peoples R China
[6] Guangxi Univ, Sch Civil Engn & Architecture, 100 Daxue East Rd, Nanning 530004, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Shield tunnel; Composite segment; Fire resistance; Thermo -mechanical behavior; Concrete damage; FEM modeling; PLASTIC-DAMAGE MODEL; REINFORCED-CONCRETE; HIGH-TEMPERATURE; ROAD TUNNEL; BEHAVIOR; PERFORMANCE; RAILWAY;
D O I
10.1016/j.tust.2022.104781
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper developed a FEM modeling to evaluate the composite segmental lining's fire resistance by simulating the thermo-mechanical behavior under the fire conditions. The mechanical and thermal properties related to concrete and steel were selected and introduced in detail. FE models of the single composite segment, segmental joint, and the full segmental lining were then established in ABAQUS. The verification of the models was conducted compared with the results from three experiments. Based on the calibrated FE models, the bearing capacity was first investigated for all three models at normal temperature and after the fire. The temperature distribution and deformation modes were subsequently examined. An in-depth discussion was conducted on the concrete damage and the corresponding protection methods. A comparison was finally carried out to detect the fire resistance between the plain concrete segment and the composite segment. The results showed that both the bearing capacity and the composite segmental joint's flexibility might significantly decrease due to the fire loading. The concrete damage was mainly caused by the rising temperature and the corresponding deformation of the whole lining ring with the expansion of different components during the fire. The restraint provided by the covered steel plates to the concrete inside led to the enhancement of the fire resistance for the composite segment. The proposed FEM model can be applied to simulate the thermo-mechanical behavior of other types of composite structures with reasonable material properties.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Experimental investigation on fire damage to staggered segmental lining of shield tunnel
    Chen, Hongbin
    Liu, Teng
    You, Xinhua
    Yuan, Dajun
    Ping, Yang
    Zhang, Qinglin
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 141
  • [2] Numerical Investigation of the Segmental Lining Performance for a Shield Tunnel
    Fan Yang
    Guang Liu
    Yan-qiao Wang
    Si-kun Yu
    KSCE Journal of Civil Engineering, 2022, 26 : 2443 - 2455
  • [3] Numerical Investigation of the Segmental Lining Performance for a Shield Tunnel
    Yang, Fan
    Liu, Guang
    Wang, Yan-qiao
    Yu, Si-kun
    KSCE JOURNAL OF CIVIL ENGINEERING, 2022, 26 (05) : 2443 - 2455
  • [4] Model of mechanical behavior with whole segmental lining of shield tunnel
    Zhang, J.-G. (zjg@sdau.edu.cn), 1600, Tsinghua University (30):
  • [5] Coupled CFD-FEM methodology for structural fire safety of composite lining shield tunnel
    Zhou, Zihao
    Shen, Yi
    Yang, Weiguang
    Yan, Zhiguo
    Zhu, Hehua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 150
  • [6] Evaluation of the load on a shield tunnel lining in gravel
    Mashimo, H
    Ishimura, T
    MODERN TUNNELING SCIENCE AND TECHNOLOGY, VOLS I AND II, 2001, : 259 - 264
  • [7] Evaluation of the load on shield tunnel lining in gravel
    Mashimo, H
    Ishimura, T
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2003, 18 (2-3) : 233 - 241
  • [8] Seismic resistance and design of shield tunnel lining with a new internal lining
    Tohda, J
    Yano, H
    Tomita, J
    EARTHQUAKE GEOTECHNICAL ENGINEERING, VOLS 1-3, 1999, : 483 - 488
  • [9] Concrete tunnel lining fire resistance and protection
    Chen, W.
    North American Tunneling 2006, 2006, : 209 - 214
  • [10] Mechanical behaviour of splicing joints in shield tunnel lining subjected to fire
    Yin Yue
    Guo Zhen
    Song Jun
    Liu Yi
    Wang Xiang-ren
    Liu Yi-bo
    Li Fu-min
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 123