Prospective evaluation of in vivo and phantom repeatability and reproducibility of diffusion-weighted MRI sequences on 1.5 T MRI-linear accelerator (MR-Linac) and MR simulator devices for head and neck cancers

被引:10
|
作者
McDonald, Brigid A. [1 ,6 ]
Salzillo, Travis [1 ]
Mulder, Samuel [1 ]
Ahmed, Sara [1 ]
Dresner, Alex [2 ]
Preston, Kathryn [1 ]
He, Renjie [1 ]
Christodouleas, John [3 ]
Mohamed, Abdallah S. R. [1 ]
Philippens, Marielle [4 ]
van Houdt, Petra
Thorwarth, Daniela
Wang, Jihong [1 ]
Dave, Amita Shukla
Boss, Michael [5 ]
Fuller, Clifton D. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Houston, TX USA
[2] Philips Healthcare, Amsterdam, Netherlands
[3] Elekta AB, Stockholm, Sweden
[4] Univ Med Ctr Utrecht, Utrecht, Netherlands
[5] Amer Coll Radiol, Washington, DC USA
[6] 1515 Holcombe Blvd, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Diffusion -weighted Imaging; MR -guided radiation therapy; MR-Linac; Test; -retest; Apparent diffusion coefficient; Repeatability and reproducibility; QUANTITATIVE IMAGING BIOMARKERS; TURBO SPIN-ECHO; TREATMENT RESPONSE; TUMOR VASCULATURE; RADIOTHERAPY; PROP;
D O I
10.1016/j.radonc.2023.109717
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Diffusion-weighted imaging (DWI) on MRI-linear accelerator (MR-linac) systems can potentially be used for monitoring treatment response and adaptive radiotherapy in head and neck can-cers (HNC) but requires extensive validation. We performed technical validation to compare six total DWI sequences on an MR-linac and MR simulator (MR sim) in patients, volunteers, and phantoms. Methods: Ten human papillomavirus-positive oropharyngeal cancer patients and ten healthy volunteers underwent DWI on a 1.5 T MR-linac with three DWI sequences: echo planar imaging (EPI), split acquisi-tion of fast spin echo signals (SPLICE), and turbo spin echo (TSE). Volunteers were also imaged on a 1.5 T MR sim with three sequences: EPI, BLADE (vendor tradename), and readout segmentation of long variable echo trains (RESOLVE). Participants underwent two scan sessions per device and two repeats of each sequence per session. Repeatability and reproducibility within-subject coefficient of variation (wCV) of mean ADC were calculated for tumors and lymph nodes (patients) and parotid glands (volunteers). ADC bias, repeatability/reproducibility metrics, SNR, and geometric distortion were quantified using a phantom. Results: In vivo repeatability/reproducibility wCV for parotids were 5.41%/6.72%, 3.83%/8.80%, 5.66%/10.03%, 3.44%/5.70%, 5.04%/5.66%, 4.23%/7.36% for EPIMR-linac, SPLICE, TSE, EPIMR sim, BLADE, RESOLVE. Repeatability/reproducibility wCV for EPIMR-linac, SPLICE, TSE were 9.64%/10.28%, 7.84%/8.96%, 7.60%/11.68% for tumors and 7.80%/9.95%, 7.23%/8.48%, 10.82%/10.44% for nodes. All sequences except TSE had phantom ADC biases within & PLUSMN; 0.1x10-3 mm2/s for most vials (EPIMR-linac, SPLICE, and BLADE had 2, 3, and 1 vials out of 13 with larger biases, respectively). SNR of b = 0 images was 87.3, 180.5, 161.3, 171.0, 171.9, 130.2 for EPIMR-linac, SPLICE, TSE, EPIMR sim, BLADE, RESOLVE. Conclusion: MR-linac DWI sequences demonstrated near-comparable performance to MR sim sequences and warrant further clinical validation for treatment response assessment in HNC. & COPY; 2023 The Authors. Published by Elsevier B.V. Radiotherapy and Oncology 185 (2023) 1-9
引用
收藏
页数:9
相关论文
共 18 条
  • [1] Repeatability of diffusion-weighted MRI in head and neck cancer at a 1.5 T MR-Linac
    Habrich, J.
    Boeke, S.
    Nachbar, M.
    Nikolaou, K.
    Schick, F.
    Gani, C.
    Zips, D.
    Thorwarth, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S147 - S148
  • [2] Prospective Test-Retest Evaluation of Diffusion-Weighted MRI Sequences On a 1.5T MR-Linac and a 1.5T MR Simulator for Oropharyngeal Cancers in Vivo and in Phantoms
    McDonald, B.
    Salzillo, T.
    Mulder, S.
    Ahmed, S.
    Dresner, A.
    Preston, K.
    He, R.
    Christodouleas, J.
    Mohamed, A.
    Wang, J.
    Van Houdt, P.
    Dave, A.
    Boss, M.
    Fuller, C.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E341 - E342
  • [3] Reproducibility of diffusion-weighted MR Imaging of Head and Neck Cancer: a Comparison of 1.5 T MR-Linac and Diagnostic 3 T MRI
    Habrich, J.
    Fritz, V.
    Boeke, S.
    Nachbar, M.
    Nikolaou, K.
    Schick, F.
    Gani, C.
    Zips, D.
    Thorwarth, D.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S57 - S58
  • [4] Study of the Repeatability of diffusion-weighted MR-Imaging of Head and Neck Tumors on the 1.5 T MR-Linac
    Habrich, J.
    Boeke, S.
    Nachbar, M.
    Nikolaou, K.
    Schick, F.
    Gani, C.
    Zips, D.
    Thorwarth, D.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (SUPPL 1) : S33 - S33
  • [5] Repeatability of diffusion-weighted magnetic resonance imaging in head and neck cancer at a 1.5 T MR-Linac
    Habrich, Jonas
    Boeke, Simon
    Nachbar, Marcel
    Nikolaou, Konstantin
    Schick, Fritz
    Gani, Cihan
    Zips, Daniel
    Thorwarth, Daniela
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 174 : 141 - 148
  • [6] Test/Retest Repeatability of diffusion-weighted MR Imaging of Head and Neck Tumors on the 1.5 T MR Linac
    Habrich, J.
    Boeke, S.
    Nachbar, M.
    Butzer, S.
    Boldt, J.
    Nikolaou, K.
    Schick, F.
    Gani, C.
    Zips, D.
    Thorwarth, D.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S56 - S57
  • [7] Prostate diffusion-weighted imaging (DWI) in MR-guided radiotherapy: Reproducibility assessment on 1.5 T MR-Linac and 1.5 T MR-simulator
    Wong, Oi Lei
    Yuan, Jing
    Poon, Darren M. C.
    Chiu, Sin Ting
    Yang, Bin
    Chiu, George
    Yu, Siu Ki
    Cheung, Kin Yin
    [J]. MAGNETIC RESONANCE IMAGING, 2024, 111 : 47 - 56
  • [8] Pulse Sequence Optimization for Non-EPI Diffusion-Weighted Imaging Sequences for Head & Neck On a 1.5T MR-Linac
    McDonald, B. A.
    Zhu, L. L.
    Mulder, S.
    Dresner, M. Alex
    Mohamed, A. S. R.
    Ahmed, S.
    He, R.
    Ding, Y.
    Fuller, C. D.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E434 - E435
  • [9] Tuning the optimal diffusion-weighted MRI parameters on a 0.35-T MR-Linac for clinical implementation: A phantom study
    Nardini, Matteo
    Capotosti, Amedeo
    Mazzoni, Lorenzo Nicola
    Cusumano, Davide
    Boldrini, Luca
    Chiloiro, Giuditta
    Romano, Angela
    Valentini, Vincenzo
    Indovina, Luca
    Placidi, Lorenzo
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12
  • [10] An In-Vivo Evaluation of MRI Sequences for Online Adaptive Cardiac Radioablation in the Presence of Cardiac Implantable Devices On a 1.5 T MR-Linac
    Akdag, O.
    Van Lier, A.
    Mandija, S.
    Keesman, R.
    Borman, P.
    Van de Pol, S.
    Verhoeff, J.
    Hoesein, F.
    Hassink, R.
    Raaymakers, B.
    Fast, M.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E176 - E176