Comparison of Mechanical Properties of Three Tissue Conditioners: An Evaluation In Vitro Study

被引:4
|
作者
Mikulewicz, Marcin [1 ]
Chojnacka, Katarzyna [2 ]
Raszewski, Zbigniew [3 ]
机构
[1] Med Univ Wroclaw, Dept Dentofacial Orthopaed & Orthodont, Div Facial Abnormal, Krakowska 26, PL-50425 Wroclaw, Poland
[2] Wroclaw Univ Sci & Technol, Fac Chem, Dept Adv Mat Technol, Smoluchowskiego 25, PL-50372 Wroclaw, Poland
[3] SpofaDental, Markova 238, Jicin 50601, Czech Republic
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 08期
关键词
tissue conditioners; phthalate-free alternatives; gelling time; adhesion; solubility; GC; Visco Gel; FITT; denture fabrication; biocompatibility; CANDIDA-ALBICANS; ANTIFUNGAL; PLASTICIZER; GELATION; ALCOHOL;
D O I
10.3390/medicina59081359
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tissue conditioners have been widely used in various clinical applications in dentistry, such as treating inflamed alveolar ridges, temporarily relining partial and complete dentures, and the acquisition of functional impressions for denture fabrication. This study aimed to investigate the mechanical properties of the most prevalent tissue conditioner materials on the market, including Tissue Conditioners (TC), Visco Gel (VG), and FITT (F). Materials and Methods: The three tissue conditioners, TC, VG, and F, were assessed based on the parameters mentioned above. The following tests were performed based on the ISO 10139-1 and ISO 10139-2 requirements: Shore A hardness, denture plate adhesion, sorption, water solubility, and contraction after 1 and 3 days in water. Additional tests are described in the literature, such as ethanol content and gelling time. The tests were carried out by storing the materials in water at 37 C-circle for 7 days. Results: The gel times of all tested materials exceeded 5 min (TC = 300 [s], VG = 350 [s]). In vitro, phthalate-free materials exhibited higher dissolution in water after 14 days (VG = 260.78 +/- 11.31 mu g/mm(2)) compared to F ( -76.12 +/- 7.11 mu g/mm(2)) and experienced faster hardening when stored in distilled water (F = 33.4 +/- 0.30 Sh. A, VG = 59.2 +/- 0.60 Sh. A). They also showed greater contractions. The connection of all materials to the prosthesis plate was consistent at 0.11 MPa. The highest counterbalance after 3 days was observed in TC = 3.53 +/- 1.12%. Conclusions: Materials containing plasticizers that are not phthalates have worse mechanical properties than products containing these substances. Since phthalates are not allowed to be used indefinitely in medical devices, additional research is necessary, especially in vivo, to develop safe materials with superior functional properties to newer-generation alternatives. In vitro results often do not agree fully with those of in vivo outcomes.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Properties of three collagen scaffolds in comparison with native connective tissue: an in-vitro study
    Solderer, Alex
    Widmer, Nicole
    Gubler, Andrea
    Fischer, Kai R.
    Hicklin, Stefan P.
    Schmidlin, Patrick R.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [2] Properties of three collagen scaffolds in comparison with native connective tissue: an in-vitro study
    Alex Solderer
    Nicole Widmer
    Andrea Gubler
    Kai R. Fischer
    Stefan P. Hicklin
    Patrick R. Schmidlin
    International Journal of Implant Dentistry, 9
  • [3] Estrogenic activity of tissue conditioners in vitro
    Hashimoto, Y
    Kawaguchi, M
    Miyazaki, K
    Nakamura, M
    DENTAL MATERIALS, 2003, 19 (04) : 341 - 346
  • [4] MECHANICAL-PROPERTIES TISSUE CONDITIONERS .2. CREEP CHARACTERISTICS
    MCCARTHY, JA
    MOSER, JB
    JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (03): : 334 - 342
  • [5] Comparison of physical and mechanical properties of three different restorative materials in primary teeth: an in vitro study
    B. Keskus
    F. Oznurhan
    European Archives of Paediatric Dentistry, 2022, 23 : 821 - 828
  • [6] Comparison of physical and mechanical properties of three different restorative materials in primary teeth: an in vitro study
    Keskus, B.
    Oznurhan, F.
    EUROPEAN ARCHIVES OF PAEDIATRIC DENTISTRY, 2022, 23 (05) : 821 - 828
  • [7] MECHANICAL-PROPERTIES OF TISSUE CONDITIONERS - THEORETICAL CONSIDERATIONS, BEHAVIORAL CHARACTERISTICS, AND TENSILE PROPERTIES
    MCCARTHY, JA
    MOSER, JB
    JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (01): : 89 - 97
  • [8] Mechanical Properties Evaluation of Three Different Materials for Implant Supported Overdenture: An In-Vitro Study
    Gibreel, Mona
    Perea-Lowery, Leila
    Lassila, Lippo
    Vallittu, Pekka K.
    MATERIALS, 2022, 15 (19)
  • [9] Comparison of the mechanical properties and mechanical damages to tendon tissue in three suspensory fixation techniques
    Kano, Toshiya
    Ishikawa, Masakazu
    Ogawa, Yuki
    Akebono, Hiroyuki
    Sugeta, Atsushi
    Ohmi, Masato
    Kamei, Goki
    Nakamae, Atsuo
    Adachi, Nobuo
    ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2022, 30 : 1 - 8
  • [10] Hardness Changes of Tissue Conditioners in Various Storage Media: An in Vitro Study
    Ntounis, Athanasios
    Kamposiora, Phophi
    Papavasiliou, George
    Divaris, Kimon
    Zinelis, Spiros
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2015, 23 (01): : 9 - 15