Convolutional neural network optimized by differential evolution for electrocardiogram classification

被引:3
|
作者
Chen, Shan Wei [1 ,2 ]
Wang, Shir Li [1 ,3 ]
Qi, XiuZhi [4 ]
Ng, Theam Foo [5 ]
Ibrahim, Haidi [6 ]
机构
[1] Univ Pendidikan Sultan Idris, Fac Comp & Meta Technol, Tanjong Malim 35900, Perak, Malaysia
[2] Baoji Univ Arts & Sci, Dept Educ, Baoji 721012, Peoples R China
[3] Univ Pendidikan Sultan Idris, Data Intelligent & Knowledge Management DILIGENT, Tanjong Malim 35900, Perak, Malaysia
[4] Baoji Univ Arts & Sci, Dept Arts, Baoji 721012, Peoples R China
[5] Univ Sains Malaysia, Ctr Global Sustainabil Studies, Minden 11800, Penang, Malaysia
[6] Univ Sains Malaysia, Sch Elect & Elect Engn, Engn Campus, Nibong Tebal 14300, Penang, Malaysia
关键词
Differential evolution; Convolutional neural network; Electrocardiogram classification; CNN;
D O I
10.1007/s11042-023-15407-9
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Coronavirus disease 2019, or COVID-19, has shifted the medical paradigm from face-to-face to telehealth. Telehealth has become a vital resource to contain the virus spread and ensure the continued care of patients. In terms of preventing cardiovascular diseases, automating electrocardiogram (ECG) classification is a promising telehealth intervention. The healthcare service ensures that patient care is appropriate, comfortable, and accessible. Convolutional neural networks (CNNs) have demonstrated promising results in ECG categorization, which require high accuracy and short training time to ensure healthcare quality. This study proposes a one-dimensional-CNN (1D-CNN) arrhythmia classification based on the differential evolution (DE) algorithm to optimize the accuracy of ECG classification and training time. The performance of 1D-CNNs of different activation functions are optimized based on the standard DE algorithm. Finally, based on MIT-BIH and SCDH arrhythmia databases, the performances of optimized and unoptimized 1D-CNN are compared and analysed. Results show that the 1D-CNN optimized by the DE has higher accuracy in heartbeats classification. The optimized 1D-CNN improves from 97.6% to 99.5% on MIT-BIH and from 80.2% to 88.5% on SCDH. Therefore, the optimized 1D-CNN shows improvements of 1.9% and 8.3% in the two datasets, respectively. In addition, compared with the unoptimized 1D-CNN based on the same parameter settings, the optimized 1D-CNN has less training time. Under the conditions of ReLU function and 10 epochs, the training takes 9.22 s on MIT-BIH and 10.35 s on SCDH, reducing training time by 67.2% and 64.2%, respectively.
引用
收藏
页码:45811 / 45837
页数:27
相关论文
共 50 条
  • [1] Convolutional neural network optimized by differential evolution for electrocardiogram classification
    Shan Wei Chen
    Shir Li Wang
    XiuZhi Qi
    Theam Foo Ng
    Haidi Ibrahim
    [J]. Multimedia Tools and Applications, 2023, 82 : 45811 - 45837
  • [2] Optimized Neural Network for Improved Electrocardiogram Beat Classification
    Dash, Sanjit K.
    Rao, G. Sasibhushana
    [J]. 2016 IEEE 6TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING (IACC), 2016, : 786 - 791
  • [3] Electrocardiogram Classification Based on Faster Regions with Convolutional Neural Network
    Ji, Yinsheng
    Zhang, Sen
    Xiao, Wendong
    [J]. SENSORS, 2019, 19 (11)
  • [4] Optimized convolutional neural network for the classification of lung cancer
    Paikaray, Divya
    Mehta, Ashok Kumar
    Khan, Danish Ali
    [J]. JOURNAL OF SUPERCOMPUTING, 2024, 80 (02): : 1973 - 1989
  • [5] Optimized convolutional neural network for the classification of lung cancer
    Divya Paikaray
    Ashok Kumar Mehta
    Danish Ali Khan
    [J]. The Journal of Supercomputing, 2024, 80 : 1973 - 1989
  • [6] Arabic Sentiment Classification Using Convolutional Neural Network and Differential Evolution Algorithm
    Dahou, Abdelghani
    Abd Elaziz, Mohamed
    Zhou, Junwei
    Xiong, Shengwu
    [J]. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2019, 2019
  • [7] Convolutional Neural Networks for Electrocardiogram Classification
    Mohamad M. Al Rahhal
    Yakoub Bazi
    Mansour Al Zuair
    Esam Othman
    Bilel BenJdira
    [J]. Journal of Medical and Biological Engineering, 2018, 38 : 1014 - 1025
  • [8] Convolutional Neural Networks for Electrocardiogram Classification
    Al Rahhal, Mohamad M.
    Bazi, Yakoub
    Al Zuair, Mansour
    Othman, Esam
    BenJdira, Bilel
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (06) : 1014 - 1025
  • [9] Identification and Classification of Electrocardiogram Signals Based On Convolutional Recurrent Neural Network
    Ma, Jinwei
    Liu, Shengping
    Chen, Guoming
    [J]. 2018 11TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2018), 2018,
  • [10] Classification of Electrocardiogram Signals for Arrhythmia Detection Using Convolutional Neural Network
    Raza, Muhammad Aleem
    Anwar, Muhammad
    Nisar, Kashif
    Ibrahim, Ag. Asri Ag
    Raza, Usman Ahmed
    Khan, Sadiq Ali
    Ahmad, Fahad
    [J]. CMC-COMPUTERS MATERIALS & CONTINUA, 2023, 77 (03): : 3817 - 3834