Analytical performance of the Enhanced Liver Fibrosis (ELF) Test on the Atellica IM Analyzer

被引:4
|
作者
Palladino, Agostino [1 ]
Gee, Matthew [1 ]
Shalhoub, Victoria [1 ]
Kiaei, David [1 ]
机构
[1] Siemens Healthcare Diagnost Inc, 511 Benedict Ave, Tarrytown, NY 10591 USA
关键词
Nonalcoholic fatty liver disease (NAFLD); Nonalcoholic steatohepatitis (NASH); Enhanced Liver Fibrosis (ELF) Test; Immunoassay; Siemens Healthineers; CLINICAL-OUTCOMES; NONINVASIVE TESTS; HEALTHY-SUBJECTS; SCORE; RISK; MANAGEMENT; MORTALITY; DIAGNOSIS; CIRRHOSIS; MARKERS;
D O I
10.1016/j.cca.2023.117461
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Enhanced Liver Fibrosis (ELFTM) Test comprises 3 direct serum markers of fibrosis-hyaluronic acid (HA), amino-terminal pro-peptide of type III procollagen (PIIINP), and tissue inhibitor of matrix metalloproteinase 1 (TIMP-1)-whose results are combined in an algorithm to generate the ELF score. Outside the U. S., the ELF Test and score are CE marked for assessment of liver fibrosis severity in patients with signs, symptoms, or risk factors of chronic liver disease to support diagnosis of fibrosis staging or prognosis for likelihood of progression to cirrhosis and liver-related clinical events. In the U.S., the FDA granted de novo marketing authorization to aid prognostic evaluation of disease progression (to cirrhosis and liver-related clinical events) in nonalcoholic steatohepatitis patients with advanced liver fibrosis. We describe the analytical performance of the ELF analytes and score on the Atellica & REG; IM Analyzer.Methods: Clinical and Laboratory Standards Institute protocols were followed for detection capability (limits of blank [LoB], detection [LoD], and quantitation [LoQ]), precision, interference, linearity, hook effect, and ELF reference interval.Results: All parameters met predetermined requirements: HA (LoB 1.00 ng/mL, LoD 2.00 ng/mL, LoQ 3.00 ng/ mL); PIIINP (LoB 0.50 ng/mL, LoD 0.75 ng/mL, LoQ 1.00 ng/mL); TIMP-1 (LoB 3.0 ng/mL, LoD 4.0 ng/mL, LoQ 5.0 ng/mL). Across the 3 assays, repeatability was <5.4% CV; within-lab precision was <8.5% CV. ELF score repeatability was <0.6% CV, within-lab precision <1.3% CV, and reproducibility <1.1% CV. Good correlation was obtained between the Atellica IM ELF and ADVIA Centaur ELF Tests (y = 1.01x - 0.22, r = 0.997). Assays were linear across analytical measuring ranges.Conclusions: Analytical performance validation results for the ELF Test and ELF score were excellent making the test acceptable for routine clinical use.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of analytical performance of the Atellica Solution IM 1600 analyzer in Korea
    Cho, S. E.
    Shin, J. Y.
    Seo, D. H.
    CLINICA CHIMICA ACTA, 2019, 493 : S36 - S36
  • [2] The Performance of Enhanced Liver Fibrosis (ELF) Test for the Staging of Liver Fibrosis: A Meta-Analysis
    Xie, Qingsong
    Zhou, Xiaohu
    Huang, Pengfei
    Wei, Jianfeng
    Wang, Weilin
    Zheng, Shusen
    PLOS ONE, 2014, 9 (04):
  • [3] The enhanced liver fibrosis (ELF) test in diagnosis and management of liver fibrosis
    Day, James W.
    Rosenberg, William M.
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2018, 79 (12) : 694 - 699
  • [4] Derivation and Performance of Standardized Enhanced Liver Fibrosis (ELF) Test Thresholds for the Detection and Prognosis of Liver Fibrosis
    Day, James
    Patel, Preya
    Parkes, Julie
    Rosenberg, William
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2019, 3 (05): : 815 - 826
  • [5] Analytical Performance Evaluation of the High Sensitivity PSA Assay and the Free PSAII Assay on the Atellica IM Analyzer
    Nissen, K. Olson
    Ngbokoli, M.
    Snyder, J.
    Pagano, M.
    Owusu, A.
    Patibandla, S.
    CLINICAL CHEMISTRY, 2024, 70
  • [6] Analytical and clinical evaluation of the enhanced liver fibrosis (ELF 2) panel
    Rosenberg, W.
    Parkes, J.
    Cross, R.
    Roderick, P.
    Dillon, P.
    Vajdi, M.
    Sampson, E. L.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A64 - A65
  • [7] FIBROSIS ASSESSMENT IN ALCOHOLIC LIVER DISEASE USING THE SIEMENS ENHANCED LIVER FIBROSIS (ELF) TEST
    Wawrzynowicz-Syczewska, M.
    Laurans, L.
    Jurczyk, K.
    Lachtara, M.
    Kornak, D.
    ALCOHOL AND ALCOHOLISM, 2013, 48 : 50 - 50
  • [8] Enhanced liver fibrosis (ELF) score: Analytical performance and distribution range in a large cohort of blood donors
    Dellavance, Alessandra
    Fernandes, Flavia
    Shimabokuro, Natalia
    Latini, Flavia
    Baldo, Danielle
    Barreto, Jose Augusto
    Marvulle, Valdecir
    Andrade, Luis Eduardo
    Ferraz, Maria Lucia
    CLINICA CHIMICA ACTA, 2016, 461 : 151 - 155
  • [9] Evaluation of the Analytical Performance of Five Chemistry Assays on the Atellica CI Analyzer
    Lewisch, S.
    Camacho, J.
    Wilkins, G.
    Gupta, P.
    Shalhoub, V.
    Snyder, J.
    CLINICAL CHEMISTRY, 2024, 70
  • [10] Evaluation of the Analytical Performance of the New Prealbumin Assay on the Atellica CH Analyzer
    Lewisch, S.
    Thomas, J.
    Maxwell, T.
    Shalhoub, V.
    Cheek, J.
    Snyder, J.
    CLINICAL CHEMISTRY, 2024, 70 : I33 - I33