Determination of trace perfluorinated compounds in environmental water samples by dispersive solid-phase extraction-high performance liquid chromatography-tandem mass spectrometry using carbon nanotube composite materials

被引:2
|
作者
Song Xinli [1 ]
Wang Ning [1 ]
He Feiyan [1 ]
Cheng Canling [1 ]
Wang Fei [1 ]
Wang Jinglong [1 ]
Zhang Lihua [1 ]
机构
[1] Zaozhuang Univ, Coll Food Sci & Pharmaceut Engn, Zaozhuang 277160, Peoples R China
关键词
carbon nanotube composite materials; dispersive solid-phase extraction ( d. SPE); liquid chromatography-tandem mass spectrometry ( LC-MS / MS); perfluorinated compounds ( PFCs); environmental water sample; SENSITIVE DETERMINATION; BAMBOO CHARCOAL; SULFONAMIDES; ACID;
D O I
10.3724/SP.J.1123.2022.09016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, carbon nanotubes ( CNTs) on silica rod ( SiO2) composite materials were prepared to extract six perfluorinated compounds ( PFCs) in real environmental water samples by high performance liquid chromatography.tandem mass spectrometry ( HPLC-MS / MS). The assynthesized sorbents, hereafter referred to as CNT@ SiO2, were employed for dispersive solid. phase extraction ( d-SPE). Perfluoroheptanoic acid ( PFHpA), perfluorohexane sulfonate ( PFHxS), perfluorooctanoic acid ( PFOA), perfluorononanoic acid ( PFNA), perfluorooctane sulfonate ( PFOS), and perfluorodecanoic acid ( PFDA) were selected as target analytes. The main extraction parameters were systematically optimized using the single-factor optimization method. The optimum adsorption parameters were as follows: adsorption time of 30 min, sorbent amount of 10 mg, pH 6 and NaCl concentration of 1.7 mol / L for sample solu. tion, and 4 mL acetone as desorption solvent, desorption for 4 min/LC. triple quadrupole MS was conducted to quantify the selected PFCs in water samples. The mobile phase was 5 mmol / L ammonium acetate and methanol, the flow rate was set to 0.4 mL / min, the column tempera. ture was set to 40 degrees C, and the injection volume was 5.0 mu L. The chromatographic separation system was equipped with a Kinetex C18 column ( 100 mmx2.1 mm, 1.7 mu m). The mass spec. trometer was operated with negative electrospray ionization in multi.reaction monitoring mode. CNT@ SiO2 was prepared in five batches and used as the d. SPE sorbent, and the relative stand. ard deviations ( RSDs) of the PFC recoveries among these five batches ranged from 4.9% to 9.3%. The reusability of the CNT@ SiO2 sorbent was assessed. After eight d.SPE cycles using the same sorbent, the RSDs of the PFC recoveries were 3.7% - 8.2%. These results indicated that the sorbent had good stability and reusability for d-SPE. Excellent results were achieved under optimal extraction conditions. The method validation results indicated that the linear ran. ges were 0.4-1 000 ng / L for PFNA, PFOS, and PFDA, 0.9-1 000 ng / L for PFHpA, 0.7- 1 000 ng / L for PFHxS, and 0.6- 1 000 ng / L for PFOA. The correlation coefficients were 0.973- 0.997. The limit of detection ( LOD) and limit of quantification of the method were 0.10- 0.26 ng / L and 0.33-0.87 ng / L, respectively. At 20 ng / L, the RSDs of the intra. and inter. day precisions were 2.73% - 7.75% and 3.38% - 8.21%, respectively. At 100 ng / L, the RSDs of the intra. and inter. day precisions were 2.95% -8.46% and 4.16% - 9.14%, respectively. Finally, at 500 ng / L, the RSDs of the intra. and inter. day precisions were 2.51% - 7.48% and 3.59% - 9.63%, respec. tively. The developed method was applied to analyze six PFCs in tap water, barreled drinking water, and river water samples. PFOA and PFOS were determined in tap water at mass concen. trations of 5.6 and 8.7 ng / L, respectively. No PFCs were found in barreled drinking water and river water. Satisfactory recoveries of 72.1% - 109.6% at low, middle, and high spiking levels were also obtained. In conclusion, the d. SPE.LC. MS / MS method based on CNT@ SiO2 compos. ite sorbents is accurate and sensitive. The results of this study demonstrate that CNT@ SiO2 is a good choice for the rapid and effective determination of PFCs from water samples. Further ex. ploration of the use of CNT@ SiO2 sorbents for the extraction and determination of trace organic pollutions in environmental samples is in progress.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 21 条
  • [1] Stir bar sorptive extraction and liquid chromatography-tandem mass spectrometry determination of polar and non-polar emerging and priority pollutants in environmental waters
    Aparicio, Irene
    Martin, Julia
    Luis Santos, Juan
    Luis Malvar, Jose
    Alonso, Esteban
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1500 : 43 - 52
  • [2] Preconcentration and Determination of Perfluoroalkyl Substances (PFASs) in Water Samples by Bamboo Charcoal-Based Solid-Phase Extraction Prior to Liquid Chromatography-Tandem Mass Spectrometry
    Deng, Ze-Hui
    Cheng, Chuan-Ge
    Wang, Xiao-Li
    Shi, Shui-He
    Wang, Ming-Lin
    Zhao, Ru-Song
    [J]. MOLECULES, 2018, 23 (04):
  • [3] Aquatic Toxicology of Perfluorinated Chemicals
    Giesy, John P.
    Naile, Jonathan E.
    Khim, Jong Seong
    Jones, Paul D.
    Newsted, John L.
    [J]. REVIEWS OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, VOL 202, 2010, 202 : 1 - 52
  • [4] Online coupling of an electrochemically fabricated solid-phase microextraction probe and a miniature mass spectrometer for enrichment and analysis of chemical contaminants in infant drinks
    Guo, Xiangyu
    Bai, Hua
    Ma, Xiaoxiao
    Li, Junfang
    Ren, Yue
    Ouyang, Zheng
    Ma, Qiang
    [J]. ANALYTICA CHIMICA ACTA, 2020, 1098 (1098) : 66 - 74
  • [5] Metal Organic Nanotubes-based Dispersive Solid Phase Extraction-as Chromatography-andem Mass Spectrometry for Sensitive Analysis of Polychlorinated Biphenyls in Environmental Water Samples
    Huang Fang
    She Xiao-Kun
    Zhou Jia-Bin
    Wang Xia
    Wang Xiao-Li
    Wang Shan-Shan
    Zhao Ru-Song
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (06) : 856 - 861
  • [6] One-pot fabrication of magnetic fluorinated carbon nanotubes adsorbent for efficient extraction of perfluoroalkyl carboxylic acids and perfluoroalkyl sulfonic acids in environmental water samples
    Huang, Youfang
    Zhang, Weihao
    Bai, Mindong
    Huang, Xiaojia
    [J]. CHEMICAL ENGINEERING JOURNAL, 2020, 380 (380)
  • [7] Synthesis of Monodisperse, Rodlike Silica Colloids with Tunable Aspect Ratio
    Kuijk, Anke
    van Blaaderen, Alfons
    Imhof, Arnout
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (08) : 2346 - 2349
  • [8] Fabrication of CoFe2O4-graphene nanocomposite and its application in the magnetic solid phase extraction of sulfonamides from milk samples
    Li, Yazhen
    Wu, Xuewen
    Li, Zhaoqian
    Zhong, Shuxian
    Wang, Weiping
    Wang, Aijun
    Chen, Jianrong
    [J]. TALANTA, 2015, 144 : 1279 - 1286
  • [9] Graphene-Fe3O4 as a magnetic solid-phase extraction sorbent coupled to capillary electrophoresis for the determination of sulfonamides in milk
    Li, Zhaoqian
    Li, Yazhen
    Qi, Mengyu
    Zhong, Shuxian
    Wang, Weiping
    Wang, Ai-Jun
    Chen, Jianrong
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (19) : 3818 - 3826
  • [10] Room-temperature synthesis of amino-functionalized magnetic covalent organic frameworks for efficient extraction of perfluoroalkyl acids in environmental water samples
    Lu, Yuan-Yue
    Wang, Xiao-Li
    Wang, Lei-Lei
    Zhang, Wen
    Wei, Jinjian
    Lin, Jin-Ming
    Zhao, Ru-Song
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 407