High-resolution MR imaging with gadoxetate disodium for the comprehensive evaluation of potential living liver donors

被引:0
|
作者
Lee, Yoonseong [1 ]
Koh, Seok Young [1 ]
Kim, Jae Hyun [1 ]
Yoo, Jeongin [1 ]
Kang, Hyojin [1 ]
Joo, Ijin [1 ]
Yoon, Jeong Hee [1 ]
Yi, Nam-joon [2 ]
Lee, Kwang-Woong [2 ]
Suh, Kyungsuk [2 ]
Lee, Jeong Min [1 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Gen Surg, Seoul, South Korea
[3] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[4] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
关键词
PREOPERATIVE EVALUATION; SINGLE-CENTER; TRANSPLANTATION; FEASIBILITY; ANATOMY; CT; QUANTIFICATION; COMPLICATIONS; ELASTOGRAPHY; ANGIOGRAPHY;
D O I
10.1097/LVT.0000000000000099
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Several major transplantation centers have used composite multimodality evaluation for the preoperative evaluation of potential living liver donors. This approach can be time-consuming and, although rare, can cause complications. We aimed to demonstrate the clinical feasibility of our comprehensive preoperative MR protocol for the preoperative assessment of living liver donor candidates instead of composite multimodality evaluation. Thirty-five consecutive living liver donor candidates underwent multiphasic liver CT and comprehensive donor protocol MR examinations for preoperative evaluation in a single large-volume liver transplantation (LT) center. Three blinded abdominal radiologists reviewed the CT and MR images for vascular and biliary variations. The strength of agreement between CT and MR angiography was assessed using the kappa index. The detection rate of biliary anatomical variations was calculated. The sensitivity and specificity for detecting significant steatosis (>5%) were calculated. The estimated total volume and right lobe volumes measured by MR volumetry were compared with the corresponding CT volumetry measurements using the intraclass correlation coefficient (ICC). Among the 35 patients, 26 underwent LT. The measurement of agreement showed a moderate to substantial agreement between CT and MR angiography interpretations (kappa values, 0.47-0.79; p < 0.001). Combining T2-weighted and T1-weighted MR cholangiography techniques detected all biliary anatomical variations in 9 of the 26 patients. MR-proton density fat fraction showed a sensitivity of 100% (3/3) and a specificity of 91.3% (21/23) for detecting pathologically determined steatosis (>5%). MR volumetry reached an excellent agreement with CT volumetry (reviewers 1 and 2: ICC, 0.92; 95% CI, 0.84-0.96). Our one-stop comprehensive liver donor MR imaging protocol can provide complete information regarding hepatic vascular and biliary anatomies, hepatic parenchymal quality, and liver volume for living liver donor candidates and can replace composite multimodality evaluation.
引用
收藏
页码:497 / 507
页数:11
相关论文
共 50 条
  • [1] Preoperative evaluation of living related liver donors using high-resolution MR angiography
    Carr, JC
    Abecassis, M
    Biel, A
    Laub, GA
    Simonetti, OP
    Finn, JP
    RADIOLOGY, 2000, 217 : 547 - 547
  • [2] Gadopentate Dimeglumine and Gadoxetate Disodium: Delayed Imaging in Liver MR
    Boriskin, H.
    Villani, R.
    Hines, J.
    Grimaldi, G.
    Ben-Levi, E.
    Friedman, B.
    Burge, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [3] Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging
    Yamada, Akira
    Hara, Takeshi
    Li, Feng
    Fujinaga, Yasunari
    Ueda, Kazuhiko
    Kadoya, Masumi
    Doi, Kunio
    RADIOLOGY, 2011, 260 (03) : 727 - 733
  • [4] CT and MR imaging evaluation of living liver donors
    Vernuccio, Federica
    Whitney, Susan A.
    Ravindra, Kadiyala
    Marin, Daniele
    ABDOMINAL RADIOLOGY, 2021, 46 (01) : 17 - 28
  • [5] CT and MR imaging evaluation of living liver donors
    Federica Vernuccio
    Susan A. Whitney
    Kadiyala Ravindra
    Daniele Marin
    Abdominal Radiology, 2021, 46 : 17 - 28
  • [6] Evaluation of Liver Function using Gadoxetate Disodium (Gd-EOB-DTPA) Enhanced MR Imaging
    Yamada, Akira
    Hara, Takeshi
    Li, Feng
    Doi, Kunio
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [7] High-resolution MR imaging evaluation of hepatocellular carcinoma
    Ohtomo, K
    Matsuoka, Y
    Abe, O
    Okada, M
    Amo, K
    Minami, M
    Kawauchi, N
    Sasaki, Y
    ABDOMINAL IMAGING, 1997, 22 (02): : 182 - 186
  • [8] High-resolution MR imaging evaluation of hepatocellular carcinoma
    K. Ohtomo
    Y. Matsuoka
    O. Abe
    M. Okada
    K. Amo
    M. Minami
    N. Kawauchi
    Y. Sasaki
    Abdominal Imaging, 1997, 22 : 182 - 186
  • [9] Hepatic Steatosis: Effect on Hepatocyte Enhancement With Gadoxetate Disodium-Enhanced Liver MR Imaging
    Onishi, Hiromitsu
    Theisen, Daniel
    Dietrich, Olaf
    Reiser, Maximilian F.
    Zech, Christoph J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 42 - 50
  • [10] Morphine three-dimensional T1 gadoxetate MR cholangiography of potential living related liver donors
    Agrawal, Mukta D.
    Mennitt, Kevin W.
    Zhang, Honglei
    Samstein, Benjamin
    Kato, Tomoaki
    Emond, Jean C.
    Dutruel, Silvina P.
    Thimmappa, Nanda Deepa
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (03) : 584 - 589