Application and Evaluation of Real-time Three-dimensional Echocardiography in Transcatheter Aortic Valve Implantation

被引:1
|
作者
Li, Jing [1 ]
Yu, Xi [1 ]
Ma, Xiaojing [1 ]
机构
[1] Wuhan Univ Sci & Technol, Wuhan Asia Gen Hosp, Wuhan Cardiovasc Imaging Clin Med Res Ctr, Dept Ultrasound, Wuhan, Peoples R China
关键词
DIAGNOSIS; ACCURACY;
D O I
暂无
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
Objective center dot This assessed the value of real-time three-dimensional echocardiography in patients with aortic valve lesions before and after transcatheter aortic valve implantation. Methods center dot A total of 61 patients were admitted for transcatheter aortic valve implantation due to aortic valve lesions between October 2021 and August 2022 (research group), and 55 patients who underwent a healthy physical examination during the same period (control group) were included. All participants underwent real-time threedimensional echocardiography. Changes in left ventricular end-diastolic volume index, left ventricular end-systolic volume index, left ventricular ejection fraction, maximum velocity, and left ventricular mass index were observed at 1 week and 1 month after the surgery. Additionally, the research group was further divided based on the type of lesion to investigate the differences in real-time threedimensional echocardiography findings between patients with moderate to severe aortic stenosis and moderate to severe aortic insufficiency. The occurrence of postoperative complications in the research group was also recorded to assess the role of real-time three-dimensional echocardiography in postoperative complication assessment after transcatheter aortic valve implantation. Results center dot Preoperative left ventricular ejection fraction did not differ significantly between the two groups (P >.05). However, the research group exhibited higher preoperative left ventricular end-diastolic volume index, left ventricular end-systolic volume index, left ventricular mass index, and maximum velocity compared to the control group (P <.05). At 1 week postoperatively, the research group showed significant reductions in left ventricular end-diastolic volume index, left ventricular end-systolic volume index, left ventricular mass index, and maximum velocity compared to preoperative values (P <.05). Furthermore, at 1 month postoperatively, the left ventricular mass index was further reduced (P <.05). Among the research group, patients with aortic stenosis had lower preoperative left ventricular end-diastolic volume index and left ventricular end-systolic volume index compared to patients with aortic insufficiency, while maximum velocity was higher (P <.05). Patients who experienced postoperative complications after transcatheter aortic valve implantation had lower left ventricular end-diastolic volume index, left ventricular end-systolic volume index and left ventricular mass index, and higher maximum velocity before and at 1 week after surgery (P <.05). Conclusions center dot Real-time three-dimensional echocardiography demonstrated excellent assessment capabilities for aortic valve lesions and accurately guided the determination of left ventricular mass index, showcasing its significant clinical applications.
引用
收藏
页码:294 / 299
页数:6
相关论文
共 50 条
  • [1] Real-Time Three-Dimensional Transesophageal Echocardiography Adds Value to Transcatheter Aortic Valve Implantation
    Smith, Lindsay A.
    Dworakowski, Rafal
    Bhan, Amit
    Delithanasis, Ioannis
    Hancock, Jane
    MacCarthy, Philip A.
    Wendler, Olaf
    Thomas, Martyn R.
    Monaghan, Mark J.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (04) : 359 - 369
  • [2] Guidance of percutaneous transcatheter aortic valve implantation by real-time three-dimensional transesophageal echocardiography - A single-center experience
    Janosi, Rolf Alexander
    Kahlert, Philipp
    Plicht, Bjoern
    Boese, Dirk
    Wendt, Daniel
    Thielmann, Matthias
    Jakob, Heinz
    Eggebrecht, Holger
    Erbel, Raimund
    Buck, Thomas
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2009, 18 (03) : 142 - 148
  • [3] Role of real-time 3-dimensional transesophageal echocardiography in transcatheter aortic valve implantation
    Bouzas-Mosquera, Alberto
    Alvarez-Garcia, Nemesio
    Ortiz-Vazquez, Eduardo
    Cuenca-Castillo, Jose J.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (05) : 909 - 909
  • [4] Application of three-dimensional transesophageal echocardiography in preoperative evaluation of transcatheter aortic valve replacement
    Peng Ding
    Chennian Xu
    Yang Liu
    Xin Meng
    Ping Jin
    Jiayou Tang
    Lanlan Li
    Yanyan Ma
    Jian Yang
    [J]. BMC Cardiovascular Disorders, 21
  • [5] Application of three-dimensional transesophageal echocardiography in preoperative evaluation of transcatheter aortic valve replacement
    Ding, Peng
    Xu, Chennian
    Liu, Yang
    Meng, Xin
    Jin, Ping
    Tang, Jiayou
    Li, Lanlan
    Ma, Yanyan
    Yang, Jian
    [J]. BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [6] Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation
    Meng, Xin
    Sun, Yandan
    Bai, Wei
    Li, Yuxi
    Tuo, Shengjun
    Cao, Liang
    Du, Mengmeng
    Liu, Yang
    Jin, Ping
    Yang, Jian
    Liu, Liwen
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (02)
  • [7] Real-time three-dimensional transoesophageal echocardiography in the assessment of aortic valve stenosis
    de la Morena, Gonzalo
    Saura, Daniel
    Oliva, Maria J.
    Soria, Federico
    Gonzalez, Josefa
    Garcia, Miguel
    Moreno, Victoria
    Bonaque, Juan C.
    Valdes, Mariano
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (01): : 9 - 13
  • [8] Real-time three-dimensional echocardiography for regional evaluation of aortic stiffness
    Nemes, Attila
    Geleijnse, Marcel L.
    Soliman, Osama I. I.
    Anwar, Ashraf M.
    Vletter, Wim B.
    ten Cate, Folkert J.
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (02): : 161 - 162
  • [9] Intraoperative Monitoring With Transesophageal Real-Time Three-Dimensional Echocardiography During Transapical Prosthetic Aortic Valve Implantation
    Marcos-Alberca, Pedro
    Luis Zamorano, Jose
    Sanchez, Tibisay
    Maroto, Luis
    Perez de Isla, Leopoldo
    Almeria, Carlos
    Macaya, Carlos
    Rodriguez, Enrique
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (03): : 352 - 356
  • [10] Three-Dimensional Echocardiography in Paravalvular Aortic Regurgitation Assessment after Transcatheter Aortic Valve Implantation
    Goncalves, Alexandra
    Almeria, Carlos
    Marcos-Alberca, Pedro
    Feltes, Gisela
    Hernandez-Antolin, Rosana
    Rodriguez, Enrique
    Silva Cardoso, Jose C.
    Macaya, Carlos
    Luis Zamorano, Jose
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 47 - 55