Real-time indoor sensing of volatile organic compounds during building disinfection events via photoionization detection and proton transfer reaction mass spectrometry

被引:11
|
作者
Ding, Xiaosu [1 ]
Lu, Hongbo [1 ]
Jiang, Jinglin [1 ]
Tasoglou, Antonios [2 ]
Shah, Amisha D. [1 ,3 ]
Jung, Nusrat [1 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, W Lafayette, IN 47907 USA
[2] RJ Lee Grp Inc, Monroeville, PA 15146 USA
[3] Purdue Univ, Div Environm & Ecol Engn, W Lafayette, IN 47907 USA
关键词
Low-cost sensors; Indoor air quality monitoring; PTR-TOF-MS; Volatile chemical emissions; Disinfectants; DEMAND-CONTROLLED VENTILATION; IONIZATION GAS-CHROMATOGRAPH; READING; 10.2; EV; FRAGMENTATION PATTERNS; EXPOSURE ASSESSMENT; CHEMICAL-EMISSIONS; FIELD-EVALUATION; AIR-POLLUTANTS; ACETIC-ACID; PTR-MS;
D O I
10.1016/j.buildenv.2023.110953
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Photoionization detectors (PIDs) are low-cost sensors that are widely used for real-time volatile organic compound (VOC) monitoring in buildings. Performance assessment of PIDs is often based on reference VOC measurements derived from offline, time-integrated sample analysis. Such assessment techniques lack valuable realtime information that is needed to evaluate how PIDs track transient VOC emission events. The objective of this study is to evaluate the real-time performance of a PID in sensing indoor VOC mixtures during building disinfection events through co-location measurements with a state-of-the-art proton transfer reaction time-of-flight mass spectrometer (PTR-TOF-MS). Field measurements were conducted in a tiny house laboratory using an isobutylene-calibrated PID and a PTR-TOF-MS during the use of spray-based disinfectants. The PID and PTR-TOFMS measurements demonstrated that chemical disinfectants are a major source of VOCs in buildings, with the latter revealing the presence of a large diversity of VOCs. In general, the PID was successful in identifying VOC emission events during the application of the disinfectants. Thus, PIDs may be suitable for integration with building automation systems for ventilation control. The PID response was much less than the PTR-TOF-MS response, suggesting that the PID is not efficiently detecting many components of the emitted VOC mixtures. The PID performed best for alcohol-based disinfectants, moderately well for lactic acid- and botanical-based disinfectants, and poorly for disinfectants featuring peracetic and acetic acid. Detailed correlation analysis between the PID and PTR-TOF-MS responses provides a basis for improving the reliability of PIDs in estimating VOC concentrations through application of product-specific correction factors.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Demonstration of proton-transfer reaction time-of-flight mass spectrometry for real-time analysis of trace volatile organic compounds
    Blake, RS
    Whyte, C
    Hughes, CO
    Ellis, AM
    Monks, PS
    ANALYTICAL CHEMISTRY, 2004, 76 (13) : 3841 - 3845
  • [2] Proton transfer reaction mass Spectrometry for Online detection of trace volatile organic compounds
    Jin Shunping
    Li Jianquan
    Han Haiyan
    Wang Hongmei
    Chu Yannan
    Zhou Shikang
    PROGRESS IN CHEMISTRY, 2007, 19 (06) : 996 - 1006
  • [3] Proton Transfer Reaction Mass Spectrometry as a Real-Time Method for Continuous Soil Organic Vapor Detection
    Sears, Joseph
    Rogers, Todd
    McCoskey, Jacob
    Lockrem, Larry
    Watts, Heather
    Pingel, Len
    Conca, James
    CONTINUOUS SOIL GAS MEASUREMENTS: WORST CASE RISK PARAMETERS, 2013, 1570 : 32 - 44
  • [4] In cleanroom, sub-ppb real-time monitoring of Volatile Organic Compounds using Proton-Transfer Reaction/Time of Flight/Mass Spectrometry
    Hayeck, Nathalie
    Maillot, Philippe
    Vitrani, Thomas
    Pic, Nicolas
    Wortham, Henri
    Gligorovski, Sasho
    Temime-Roussel, Brice
    Mizzi, Aurelie
    Poulet, Irene
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXVIII, 2014, 9050
  • [5] Real-time monitoring of respiratory absorption factors of volatile organic compounds in ambient air by proton transfer reaction time-of-flight mass spectrometry
    Huang, Zhonghui
    Zhang, Yanli
    Yan, Qiong
    Zhang, Zhou
    Wang, Xinming
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 320 : 547 - 555
  • [6] Proton Transfer Reaction Time. of. Flight Mass Spectrometry for Detection of Trace Volatile Organic Compounds in Breath
    Han Ming-Cong
    Dong Jun-Guo
    Peng, Zhen
    Xu Li
    Cheng Ping
    Zhou Zhen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (07) : 1109 - 1115
  • [7] Development of Dipolar Proton Transfer Reaction Mass Spectrometer for Real-time Monitoring of Volatile Organic Compounds in Ambient Air
    Zhang Qiang-Ling
    Zou Xue
    Liang Qu
    Zhang Ya-Ting
    Yi Ming-Jian
    Wang Hong-Mei
    Huang Chao-Qun
    Shen Cheng-Yin
    Chu Yan-Nan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (04) : 471 - 478
  • [8] Detection of volatile organic compounds in upland peat by means of proton-transfer-reaction mass spectrometry
    Mezhibor, A. M.
    Bonn, B.
    XV INTERNATIONAL SCIENTIFIC CONFERENCE CHEMISTRY AND CHEMICAL ENGINEERING IN XXI CENTURY DEDICATED TO PROFESSOR L.P. KULYOV, 2014, 10 : 203 - 208
  • [9] Proton Transfer Reaction Mass Spectrometry for On-line Detection of Trace Volatile Organic Compounds in Breath
    Shen Cheng-Yin
    Li Jian-Quan
    Wang Hong-Zhi
    Zhi Zhong-Hua
    Wang Hong-Mei
    Huang Chao-Qun
    Liu Sheng
    Jiang Hai-He
    Chu Yan-Nan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (05) : 773 - 777
  • [10] Real-time metabolic monitoring with proton transfer reaction mass spectrometry
    Winkler, Klaus
    Herbig, Jens
    Kohl, Ingrid
    JOURNAL OF BREATH RESEARCH, 2013, 7 (03)