Paper microfluidics with deep learning for portable intelligent nucleic acid amplification tests

被引:6
|
作者
Sun, Hao [1 ,2 ]
Xie, Wantao [1 ,2 ]
Huang, Yi [3 ]
Mo, Jin [1 ,2 ]
Dong, Hui [1 ,2 ]
Chen, Xinkai [4 ]
Zhang, Zhixing [5 ]
Shang, Junyi [6 ]
机构
[1] Fuzhou Univ, Sch Mech Engn & Automat, Fuzhou 350108, Peoples R China
[2] Fujian Prov Collaborat Innovat Ctr High End Equipm, Fuzhou 350108, Peoples R China
[3] Fujian Prov Hosp, Ctr Expt Res Clin Med, Fuzhou 350001, Peoples R China
[4] Star Net Ruijie Sci & Technol Co Ltd, Beijing 350108, Peoples R China
[5] Shenzhen Technol Univ, Sino German Coll Intelligent Mfg, Shenzhen 518118, Peoples R China
[6] Beijing Inst Technol, Sch Automat, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Paper microfluidics; NAAT; Deep learning; COVID-19; diagnosis;
D O I
10.1016/j.talanta.2023.124470
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During global outbreaks such as COVID-19, regular nucleic acid amplification tests (NAATs) have posed unprecedented burden on hospital resources. Data of traditional NAATs are manually analyzed post assay. Integration of artificial intelligence (AI) with on-chip assays give rise to novel analytical platforms via data-driven models. Here, we combined paper microfluidics, portable optoelectronic system with deep learning for SARSCoV-2 detection. The system was quite streamlined with low power dissipation. Pixel by pixel signals reflecting amplification of synthesized SARS-CoV-2 templates (containing ORF1ab, N and E genes) can be real-time processed. Then, the data were synchronously fed to the neural networks for early prediction analysis. Instead of the quantification cycle (Cq) based analytics, reaction dynamics hidden at the early stage of amplification curve were utilized by neural networks for predicting subsequent data. Qualitative and quantitative analysis of the 40-cycle NAATs can be achieved at the end of 22nd cycle, reducing time cost by 45%. In particular, the attention mechanism based deep learning model trained by microfluidics-generated data can be seamlessly adapted to multiple clinical datasets including readouts of SARS-CoV-2 detection. Accuracy, sensitivity and specificity of the prediction can reach up to 98.1%, 97.6% and 98.6%, respectively. The approach can be compatible with the most advanced sensing technologies and AI algorithms to inspire ample innovations in fields of fundamental research and clinical settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Integrated smart analytics of nucleic acid amplification tests via paper microfluidics and deep learning in cloud computing
    Sun, Hao
    Jiang, Qinghua
    Huang, Yi
    Mo, Jin
    Xie, Wantao
    Dong, Hui
    Jia, Yuan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 83
  • [2] Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests
    Reynolds, Jocelyn
    Loeffler, Reid S.
    Leigh, Preston J.
    Lopez, Hannah A.
    Yoon, Jeong-Yeol
    BIOSENSORS-BASEL, 2023, 13 (09):
  • [3] Portable instrument for paper-based isothermal nucleic acid amplification tests
    Liu, Mingdian
    Tang, Zheyan
    Monshat, Hosein
    Zhao, Yuxin
    Lu, Meng
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [4] Paper microfluidics for nucleic acid amplification testing (NAAT) of infectious diseases
    Magro, Laura
    Escadafal, Camille
    Garneret, Pierre
    Jacquelin, Beatrice
    Kwasiborski, Aurelia
    Manuguerra, Jean-Claude
    Monti, Fabrice
    Sakuntabhai, Anavaj
    Vanhomwegen, Jessica
    Lafaye, Pierre
    Tabeling, Patrick
    LAB ON A CHIP, 2017, 17 (14) : 2347 - 2371
  • [5] Paper-Based Loop Mediated Isothermal Amplification (LAMP) Platforms: Integrating the Versatility of Paper Microfluidics with Accuracy of Nucleic Acid Amplification Tests
    Das, Debayan
    Masetty, Manaswini
    Priye, Aashish
    CHEMOSENSORS, 2023, 11 (03)
  • [6] Digital Microfluidics for Nucleic Acid Amplification
    Coelho, Beatriz
    Veigas, Bruno
    Fortunato, Elvira
    Martins, Rodrigo
    Aguas, Hugo
    Igreja, Rui
    Baptista, Pedro V.
    SENSORS, 2017, 17 (07):
  • [7] Roll-to-roll fabrication of integrated PDMS-paper microfluidics for nucleic acid amplification
    Hiltunen, Jussi
    Liedert, Christina
    Hiltunen, Marianne
    Huttunen, Ow-Heikki
    Hiitota-Keinanen, Johanna
    Aikio, Sanna
    Harjanne, Mikko
    Kurkinen, Marika
    Hakalahti, Leena
    Lee, Luke P.
    LAB ON A CHIP, 2018, 18 (11) : 1552 - 1559
  • [8] Paper-based nucleic acid amplification tests for point-of-care diagnostics
    Kaur, Navjot
    Toley, Bhushan J.
    ANALYST, 2018, 143 (10) : 2213 - 2234
  • [9] A portable system for economical nucleic acid amplification testing
    Dong, Hui
    Mo, Jin
    Yu, Yongjian
    Xie, Wantao
    Zheng, Jianping
    Jia, Chao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [10] Nucleic acid amplification tests for the diagnosis of pneumonia
    Murdoch, DR
    CLINICAL INFECTIOUS DISEASES, 2003, 36 (09) : 1162 - 1170