Electrical impedance myography in healthy volunteers

被引:1
|
作者
Offit, Michelle B. [1 ,2 ]
Khanli, Hadi Mohammad [1 ,3 ]
Wu, Tianxia [4 ]
Lehky, Tanya J. [1 ,5 ]
机构
[1] Natl Inst Hlth Neurol Disorders & Stroke, Electromyog Sect, NIH, Bethesda, MD USA
[2] Georgetown Univ, Neurol Dept, Washington, DC USA
[3] City Hope Comprehens Canc Ctr, Neurol Dept, Duarte, CA USA
[4] Natl Inst Hlth Neurol Disorders & Stroke, Clin Trials Unit, NIH, Bethesda, MD USA
[5] NINDS, EMG Sect, NIH, Bldg 10-7-5680, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
elastography; electrical impedance myography; muscle physiology; ultrasound; SPINAL MUSCULAR-ATROPHY; QUANTITATIVE ULTRASOUND; DYSTROPHY;
D O I
10.1002/mus.27978
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction/AimsElectrical impedance myography (EIM) is a noninvasive technique being used in clinical studies to characterize muscle by phase, reactance, and resistance after application of a low-intensity current. The aim of this study was to obtain 50-kHz EIM data from healthy volunteers (HVs) for use in future clinical and research studies, perform reliability tests on EIM outcome measures, and compare findings with muscle ultrasound variables.MethodsFour arm and four leg muscles of HVs were evaluated using an EIM device with two sensors, P/N 20-0045 and P/N 014-009. Muscles were evaluated individually and eight-muscle average (8MU), four-muscle upper extremity average, and four-muscle lower extremity average. An intraclass correlation coefficient (ICC) was applied to assess interrater, intrarater, and intersensor reliability using a subset of HVs. Ultrasound studies on muscle thickness and elastography were also performed on a subset of HVs.ResultsFor the P/N 20-0045 sensor, the 8MU EIM mean and standard deviation (n = 41) was 14.54 +/- 3.31 for phase, 7.04 +/- 1.22 for reactance, and 28.91 +/- 7.63 for resistance. Reliability for 8MU phase (n = 22) was good to excellent for both interrater (n = 22, ICC = 0.920, 95% CI 0.820 to 0.966) and intrarater (n = 22, ICC = 0.950, 95% CI 0.778 to 0.983). The P/N 014-009 sensor had similar reliability findings. Correlation analyses showed no association between EIM and muscle thickness.DiscussionEIM is a reproducible measure of muscle physiology. Obtaining EIM values from HVs allows us to gain a better understanding how EIM may be altered in diseased muscle.
引用
收藏
页码:288 / 294
页数:7
相关论文
共 50 条
  • [1] ELECTRICAL IMPEDANCE MYOGRAPHY IN NORMAL VOLUNTEERS
    Offit, Michelle
    Khanli, Hadi Mohammad
    Wu, Tianxia
    Lehky, Tanya
    [J]. MUSCLE & NERVE, 2022, 66 : S72 - S72
  • [2] Intra- and inter-rater reliability of electrical impedance myography using adhesive electrodes in healthy volunteers
    Martinez-Gonzalez, Mariano
    Montilla-Herrador, Joaquina
    Garcia-Vidal, Jose A.
    Escolar-Reina, Pilar
    Gacto-Sanchez, Mariano
    Medina-Mirapeix, Francesc
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2020, 55
  • [3] Electrical impedance myography in healthy dogs: Normative values, repeatability, and the impact of age
    Verga, Sarah A. A.
    Pandeya, Sarbesh R. R.
    Kowal, Joseph B. B.
    Cochran, Randall J. J.
    Lim, Stefanie
    Sabol, Julianna C. C.
    Coates, Joan R. R.
    Rutkove, Seward B. B.
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [4] Electrical impedance myography in the detection of radiculopathy
    Rutkove, SB
    Esper, GJ
    Lee, KS
    Aaron, R
    Shiffman, CA
    [J]. MUSCLE & NERVE, 2005, 32 (03) : 335 - 341
  • [5] Electrical impedance myography as a biomarker for ALS
    Rutkove, Seward
    [J]. LANCET NEUROLOGY, 2009, 8 (03): : 226 - 226
  • [6] ELECTRICAL IMPEDANCE MYOGRAPHY IN THE DIAGNOSIS OF RADICULOPATHY
    Spieker, Andrew J.
    Narayanaswami, Pushpa
    Fleming, Laura
    Keel, John C.
    Muzin, Stefan C.
    Rutkove, Seward B.
    [J]. MUSCLE & NERVE, 2013, 48 (05) : 800 - 805
  • [7] Electrical impedance myography at high frequencies
    Shiffman, C. A.
    Kashuri, H.
    Aaron, R.
    [J]. 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 739 - 742
  • [8] Test-retest reliability of electrical impedance myography in hamstrings of healthy young men
    Honorato, Renee de Caldas
    Marreiros Ferraz, Alex Soares
    Kassiano, Witalo
    Carvalho, Denise Pires
    Ceccatto, Vania Marilande
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2021, 56
  • [9] Electrical Impedance Myography in Dogs With Degenerative Myelopathy
    Kowal, Joseph B.
    Verga, Sarah A.
    Pandeya, Sarbesh R.
    Cochran, Randall J.
    Sabol, Julianna C.
    Rutkove, Seward B.
    Coates, Joan R.
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [10] ELECTRICAL IMPEDANCE MYOGRAPHY IN FACIOSCAPULOHUMERAL MUSCULAR DYSTROPHY
    Statland, Jeffrey M.
    Heatwole, Chad
    Eichinger, Katy
    Dilek, Nuran
    Martens, William B.
    Tawil, Rabi
    [J]. MUSCLE & NERVE, 2016, 54 (04) : 696 - 701