Experimental performance and evaluation of direct evaporative cooling system coupled with a desiccant wheel in a closed greenhouse

被引:1
|
作者
Kamrani, Fatemeh [1 ]
Montazeri, Mehdi [1 ]
Banakar, Ahmad [1 ]
Ghobadian, Barat [1 ]
Pasdarshahri, Hadi [2 ]
机构
[1] Tarbiat Modares Univ, Fac Agr, Dept Biosyst Engn, POB 14115-336, Tehran 14114, Iran
[2] Tarbiat Modares Univ, Dept Mech Engn, POB 14115-143, Tehran, Iran
关键词
Fan-Pad cooling system; Temperature and humidity distribution; Solar radiation; TRNSYS modeling;
D O I
10.1016/j.ecmx.2023.100497
中图分类号
O414.1 [热力学];
学科分类号
摘要
The greenhouse is one of the most advanced technologies protecting products against inconvenient climates. However, high humidity and temperature throughout the summer, particularly in closed greenhouses, have a reverse effect on the crops. In such conditions, reducing the temperature inside the greenhouse seems indis-pensable. Therefore, in this study, two different patterns of cooling systems, namely, direct evaporation and mixed direct evaporative desiccant rotatory wheel, were designed and developed in Tehran. The results of these models were evaluated, compared, and modeled in TRNSYS. Subsequently, for performance prediction of these models, they were examined in closed greenhouses located in 5 regions in Iran: Astara, Ahvaz, Bandar-abbas, Tehran, and Shiraz. The temperature and humidity in different parts of the greenhouse were measured and reported to assess the performance of these two systems in terms of the capability to supply the required cooling load, energy consumption, and functional expenses. The experimental results indicated that the direct evapo-rative cooling system isn't acceptable for cooling the closed greenhouse in the preceding regions. This system in conventional greenhouses can be applicable only in Astara, Tehran, and Shiraz. Although all traditional greenhouses in Tehran use a direct evaporative cooling pad system, such a system cannot be used for cooling the closed greenhouses. Also, findings of the present study indicated that despite the 10% increase in radiation in-tensity and 7% increase in temperature in the case of evaluating the mixed evaporative desiccant rotatory wheel system, the temperature changes of greenhouse in this system followed a similar behavior, and 8% reduction in functional expenses was also confirmed.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Performance evaluation of a desiccant-evaporative cooling system
    Sheer, TJ
    Thom, MG
    [J]. NATURAL WORKING FLUIDS'98: IIR - GUSTAV LORENTZEN CONFERENCE, 1998, 1998 (04): : 114 - 124
  • [2] Designing, Modelling and Experimental Investigation of Direct Evaporative Cooling System Coupled With Commercial Desiccant Dehumidifier
    Basit, Abdul
    Mahmood, Mariam
    Waqas, Adeel
    Ali, Majid
    Khalid, Waqas
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (07)
  • [3] Performance enhancement of a desiccant evaporative cooling system using direct/indirect evaporative cooler
    Elgendy, E.
    Mostafa, A.
    Fatouh, M.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 77 - 87
  • [4] A methodology for the performance evaluation of an experimental desiccant cooling system
    Çarpinlioglu, MO
    Yildirim, M
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2005, 32 (10) : 1400 - 1410
  • [5] Performance Evaluation of a Solar-Aided Liquid Desiccant Evaporative Cooling System
    Reddy, Sneha
    Priya, S. Shanmuga
    Kuma, S. Harish
    [J]. INTERNATIONAL CONFERENCE ON SUSTAINABLE ENGINEERING AND TECHNOLOGY (ICONSET 2018), 2018, 2039
  • [6] Experimental study on exhaust internal circulation desiccant wheel evaporative cooling chiller
    Yang, Tingting
    Chen, Liu
    Feng, Yuan
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [7] The effects of regeneration temperature of the desiccant wheel on the performance of desiccant cooling cycles for greenhouse thermally insulated
    Rjibi, Amel
    Kooli, Sami
    Guizani, Amenaallah
    [J]. HEAT AND MASS TRANSFER, 2018, 54 (11) : 3427 - 3443
  • [8] The effects of regeneration temperature of the desiccant wheel on the performance of desiccant cooling cycles for greenhouse thermally insulated
    Amel Rjibi
    Sami Kooli
    Amenaallah Guizani
    [J]. Heat and Mass Transfer, 2018, 54 : 3427 - 3443
  • [9] Studying the performance of a liquid desiccant indirect evaporative cooling system
    Cui, Xin
    Liu, Yanhua
    Liu, Yilin
    Jin, Liwen
    Zhao, Min
    Meng, Xiangzhao
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5659 - 5665
  • [10] Experimental study of an ultrasonic regenerative evaporative cooler for a desiccant cooling system
    Arun, B. S.
    Mariappan, V.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (02): : 151 - 175