Biomechanical effects of different staging and attachment designs in maxillary molar distalization with clear aligner: a finite element study

被引:1
|
作者
Gao, Jie [1 ]
Guo, Donghui [1 ]
Zhang, Xu [1 ]
Cheng, Yuxun [1 ]
Zhang, Hao [1 ]
Xu, Yuerong [1 ]
Jin, Zuolin [1 ]
Ma, Yanning [1 ,2 ]
机构
[1] Fourth Mil Med Univ, Natl Clin Res Ctr Oral Dis, Shaanxi Clin Res Ctr Oral Dis, Sch Stomatol,State Key Lab Oral & Maxillofacial Re, 169 Changle West Rd, Xian 710032, Peoples R China
[2] Shanxi Med Univ, Sch & Hosp Stomatol, Taiyuan 030001, Peoples R China
关键词
Clear aligner; Molar distalization; Different staging design; Different attachment; PENDULUM APPLIANCE; TOOTH MOVEMENT; INVISALIGN; EFFICIENCY;
D O I
10.1186/s40510-023-00493-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundIn the present study, the effects of distalizations of one and two molars with different step distances and attachment designs have been analyzed.MethodsA 3D finite element analysis model has been developed in order to determine the tendency of tooth displacement and stress distribution with clear aligner treatment.ResultsUnder the condition of single-molar distalization, when the step distance was set to 0.25 mm, the total displacement was 0.086 mm for central incisors, 0.080 mm for lateral incisors, 0.084 mm for canines, 0.102 mm for the first premolar and 0.076 mm for the second premolar. The von Mises stress of roots and the principal stress of the periodontal ligament was slightly lower than in the control group when the step distance was set to 0.130 mm. Under the condition of two-molar distalization, when the step distance was set to 0.130 mm, the total displacements for central incisors, lateral incisors and canines as well as both the first and second maxillary molars were basically the same as with a distance of 0.250 mm for one-molar distalization. In addition, when the step distance was 0.130 mm with two-molar distalization, the rotation center of the first and second molar was closer to the apex of the root indicating that the smaller step distance led to more bodily movement during the two-molar distalization. However, displacement tendencies of the first molar and the second molar were basically the same whether horizontal or vertical rectangular attachments were added.ConclusionsA step distance of moving two molars to 0.130 mm can achieve the same reaction force on the anterior teeth as moving one molar 0.250 mm without effects on horizontal or vertical rectangular attachments.Clinical relevanceOur results provide a theoretical basis and guidance for simultaneously moving two molars backward in clinical practice using a clear aligner.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [1] Biomechanical effects of different staging and attachment designs in maxillary molar distalization with clear aligner: a finite element study
    Jie Gao
    Donghui Guo
    Xu Zhang
    Yuxun Cheng
    Hao Zhang
    Yuerong Xu
    Zuolin Jin
    Yanning Ma
    Progress in Orthodontics, 24
  • [2] The effect of maxillary molar distalization with clear aligner: a 4D finite-element study with staging simulation
    Mao, Bochun
    Tian, Yajing
    Xiao, Yujia
    Li, Jing
    Zhou, Yanheng
    PROGRESS IN ORTHODONTICS, 2023, 24 (01)
  • [3] The effect of maxillary molar distalization with clear aligner: a 4D finite-element study with staging simulation
    Bochun Mao
    Yajing Tian
    Yujia Xiao
    Jing Li
    Yanheng Zhou
    Progress in Orthodontics, 24
  • [4] Morphology Changes of Maxillary Molar Distalization by Clear Aligner Therapy
    Cui, Jia-Yu
    Ting, Liu
    Cao, Yu-Xin
    Sun, Dan-Xu
    Bing, Li
    Wu, Xiu-Ping
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2022, 40 (04): : 920 - 926
  • [5] Effects of different distalization directions and methods on maxillary total distalization with clear aligners: a finite element study
    Kwak, Kyoung-Ho
    Oh, Sewoong
    Choi, Youn-Kyung
    Kim, Sung-Hun
    Kim, Seong-Sik
    Park, Soo-Byung
    Kim, Yong-Il
    ANGLE ORTHODONTIST, 2023, 93 (03) : 348 - 356
  • [6] Biomechanical Characteristics of Maxillary Molar Distalization Using Different Attachments with Clear Aligners: A 3-Dimensional Finite Element Analysis
    Chi, Jingwen
    Yang, Lixia
    Liu, Yicong
    Yang, Jianjun
    Deng, Jing
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1738 - 1744
  • [7] Evaluation of biomechanics using different traction devices in distalization of maxillary molar with clear aligners: a finite element study
    Ji, Lili
    Li, Bing
    Wu, Xiuping
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (05) : 559 - 567
  • [8] Upper First Molar and Second Premolar Distalization with Clear Aligner and Interradicular Skeletal Anchorage: A Finite Element Study
    Castroflorio, Tommaso
    Parrini, Simone
    Rossini, Gabriele
    Nebiolo, Bianca
    Gavetti, Flavia
    Quinzi, Vincenzo
    Derton, Nicola
    Greco, Mario Alessandro
    Deregibus, Andrea
    APPLIED SCIENCES-BASEL, 2023, 13 (17):
  • [9] Effect of Different Anchorage Reinforcement Methods on Long-Term Maxillary Whole Arch Distalization with Clear Aligner: A 4D Finite Element Study with Staging Simulation
    Mao, Bochun
    Tian, Yajing
    Xiao, Yujia
    Liu, Jiayi
    Liu, Dawei
    Zhou, Yanheng
    Li, Jing
    BIOENGINEERING-BASEL, 2024, 11 (01):
  • [10] Biomechanical analysis of the effect of Class II traction configurations and aligner overtreatment on molar distalization: a finite-element study
    Li, Jialun
    Yang, Yi
    Tang, Ziwei
    Fan, Qi
    Ghaleb, Omar M.
    He, Xian
    Lai, Wenli
    Long, Hu
    EUROPEAN JOURNAL OF ORTHODONTICS, 2024, 46 (06)