BLU-DAT: a new reliable and accurate arthrometer for measuring anterior knee laxity

被引:1
|
作者
Colosio, Alessandro [1 ,4 ]
Scaini, Alessandra [1 ,2 ]
Motta, Marcello [1 ]
Paderno, Marco [2 ,4 ]
Saccomanno, Maristella F. [1 ,2 ,4 ]
Bettinsoli, Pierfrancesco [3 ]
Bonaspetti, Giovanni [3 ]
Milano, Giuseppe [1 ,2 ,4 ]
机构
[1] Univ Brescia, Dept Med & Surg Specialties Radiol Sci & Publ Hlth, Brescia, Italy
[2] Spedali Civil Brescia, Dept Bone & Joint Surg, Brescia, Italy
[3] Clin S Anna, Dept Orthopaed & Traumatol, Brescia, Italy
[4] UOC Clin Ortoped, ASST Spedali Civili, Piazzale Spedali Civili 1, I-25123 Brescia, BS, Italy
关键词
Knee; Anterior cruciate ligament; Anterior tibial translation; Arthrometer; SAMPLE-SIZE; RELIABILITY; METAANALYSIS; HEALTHY;
D O I
10.1007/s00167-023-07534-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeAlthough many arthrometers have been developed to assess anterior knee laxity, reliability and diagnostic accuracy of these devices are still debated. The aim of the present study was to evaluate the validity of a new arthrometer in the outpatient setting, with the hypothesis that it had good validity in terms of reliability and diagnostic accuracy.MethodsSeventy-eight subjects (39 with ACL injury and 39 with normal ACL) were tested. ATT was assessed by means of the Lachman test at 30 & DEG; of flexion with a new testing device (BLU-DAT) under three different loading conditions: 7 kg (69 N), 9 kg (88 N) and maximum (MMT). The tests were performed on both knees to obtain SSD. In the ACL injury group, the tests were performed by two examiners and one of them repeated a second test series. Inter- and intra-observer reliability were assessed with the intraclass correlation coefficients (ICCs) for the average SSD measures. In the normal-ACL group, the analysis was performed with the same testing setup. Side-to-side difference measures of the two groups at every loading condition were compared by Student's t test. Data of test series were dichotomized based on the threshold value of 3-mm SSD as pathological ATT and 2 x 2 contingency tables were used to assess diagnostic accuracy.ResultsThe ICCs for intra-observer reliability at 7-kg (69 N), 9-kg (88 N) and MMT measurements were 0.781, 0.855 and 0.913, respectively. The ICC for inter-observer reliability at 7-kg (69 N), 9-kg (88 N) and MMT measurements were 0.701, 0.845 and 0.834, respectively. Comparison between the two groups showed a significant mean difference ranging from 3.4 mm for 7-kg (69 N) load to 4.6 mm for MMT. Overall accuracy ranged from 84.6% for 7-kg load to 98.7% for MMT.ConclusionThe BLU-DAT has proven to be an instrument with good intra- and inter-observer reliability and very good accuracy in the diagnosis of ACL injuries in the outpatient setting. So, the BLU-DAT can be a new useful tool in everyday clinical practice to assist in the diagnosis of ACL injury.
引用
收藏
页码:4782 / 4790
页数:9
相关论文
共 31 条
  • [1] BLU-DAT: a new reliable and accurate arthrometer for measuring anterior knee laxity
    Alessandro Colosio
    Alessandra Scaini
    Marcello Motta
    Marco Paderno
    Maristella F. Saccomanno
    Pierfrancesco Bettinsoli
    Giovanni Bonaspetti
    Giuseppe Milano
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 4782 - 4790
  • [2] RELIABILITY OF MEASURING ANTERIOR LAXITY OF THE KNEE-JOINT USING A KNEE LIGAMENT ARTHROMETER
    HANTEN, WP
    PACE, MB
    PHYSICAL THERAPY, 1987, 67 (03): : 357 - 359
  • [3] Reliability of a Novel Automatic Knee Arthrometer for Measuring Knee Laxity After Anterior Cruciate Ligament Ruptures
    Niu, Xingyue
    Mai, Hemuti
    Wu, Tong
    Jiang, Yanfang
    Duan, Xiaoning
    Liu, Mengzhen
    Liu, Jingyu
    Ding, Li
    Ao, Yingfang
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (02)
  • [4] A new knee arthrometer demonstrated to be reliable and accurate to assess anterior tibial translation in comparison with stress radiographs
    Milano, Giuseppe
    Colosio, Alessandro
    Scaini, Alessandra
    Motta, Marcello
    Raggi, Andrea
    Zanoni, Fabio
    Galli, Stefano
    Saccomanno, Maristella F.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3241 - 3250
  • [5] A new knee arthrometer demonstrated to be reliable and accurate to assess anterior tibial translation in comparison with stress radiographs
    Giuseppe Milano
    Alessandro Colosio
    Alessandra Scaini
    Marcello Motta
    Andrea Raggi
    Fabio Zanoni
    Stefano Galli
    Maristella F. Saccomanno
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3241 - 3250
  • [6] Intra-rater reliability of the knee arthrometer GNRB? for measuring knee anterior laxity in healthy, active subjects
    Magdic, Miha
    Dahmane, Raja Gosnak
    Vauhnik, Renata
    JOURNAL OF ORTHOPAEDICS, 2023, 39 : 7 - 10
  • [7] Analyzing Anterior Knee Laxity with an Arthrometer for Assisting Diagnosis of Anterior Cruciate Ligament Rupture
    Lin, H. C.
    Hsu, H. C.
    Chang, C. M.
    Lai, W. H.
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 438 - +
  • [8] Reliability of the KT-1000 arthrometer (Medmetric) for measuring anterior knee laxity: comparison with Telos in 147 knees
    Boyer, P
    Djian, R
    Christel, R
    Paoletti, X
    Degeorges, R
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (08): : 757 - 764
  • [9] Anterior knee laxity measurement: Comparison of passive stress radiographs Telos® and "Lerat", and GNRB® arthrometer
    Beldame, J.
    Mouchel, S.
    Bertiaux, S.
    Adam, J. -M.
    Mouilhade, F.
    Roussignol, X.
    Dujardin, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (07) : 744 - 750
  • [10] THE MEASUREMENT OF THE ANTERIOR LAXITY OF THE KNEE USING DYNAMIC X-RAYS AND ARTHROMETER KT-1000
    LERAT, JL
    MOYEN, B
    LATOUR, LD
    MAINETTI, E
    LALAIN, JJ
    BRUNET, E
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1988, 74 : 194 - 197