Evaluation of Pulmonary Nodules by Radiologists vs. Radiomics in Stand-Alone and Complementary CT and MRI

被引:1
|
作者
Tietz, Eric [1 ,2 ]
Mueller-Franzes, Gustav [1 ]
Zimmermann, Markus [1 ]
Kuhl, Christiane Katharina [1 ]
Keil, Sebastian [1 ]
Nebelung, Sven [1 ]
Truhn, Daniel [1 ]
机构
[1] RWTH Aachen Univ Hosp, Dept Diagnost & Intervent Radiol, Pauwelsstr 30, D-52072 Aachen, Germany
[2] Univ Dusseldorf, Med Fac, Dept Diagnost & Intervent Radiol, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
CT; MRI; pulmonary nodule; artificial intelligence; radiomics; LUNG-CANCER; MANAGEMENT; IMAGES;
D O I
10.3390/diagnostics14050483
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Increased attention has been given to MRI in radiation-free screening for malignant nodules in recent years. Our objective was to compare the performance of human readers and radiomic feature analysis based on stand-alone and complementary CT and MRI imaging in classifying pulmonary nodules. This single-center study comprises patients with CT findings of pulmonary nodules who underwent additional lung MRI and whose nodules were classified as benign/malignant by resection. For radiomic features analysis, 2D segmentation was performed for each lung nodule on axial CT, T2-weighted (T2w), and diffusion (DWI) images. The 105 extracted features were reduced by iterative backward selection. The performance of radiomics and human readers was compared by calculating accuracy with Clopper-Pearson confidence intervals. Fifty patients (mean age 63 +/- 10 years) with 66 pulmonary nodules (40 malignant) were evaluated. ACC values for radiomic features analysis vs. radiologists based on CT alone (0.68; 95%CI: 0.56, 0.79 vs. 0.59; 95%CI: 0.46, 0.71), T2w alone (0.65; 95%CI: 0.52, 0.77 vs. 0.68; 95%CI: 0.54, 0.78), DWI alone (0.61; 95%CI:0.48, 0.72 vs. 0.73; 95%CI: 0.60, 0.83), combined T2w/DWI (0.73; 95%CI: 0.60, 0.83 vs. 0.70; 95%CI: 0.57, 0.80), and combined CT/T2w/DWI (0.83; 95%CI: 0.72, 0.91 vs. 0.64; 95%CI: 0.51, 0.75) were calculated. This study is the first to show that by combining quantitative image information from CT, T2w, and DWI datasets, pulmonary nodule assessment through radiomics analysis is superior to using one modality alone, even exceeding human readers' performance.
引用
收藏
页数:10
相关论文
共 36 条
  • [1] CFD for Electronics Cooling: MCAD and EDA Embedded vs. Stand-alone
    Parry, John D.
    14TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATION OF ICS AND SYSTEMS, 2008, : 1 - 7
  • [2] Digital mental health interventions as stand-alone vs. augmented treatment as usual
    Nelson, Benjamin W.
    Peiper, Nicholas C.
    Forman-Hoffman, Valerie L.
    BMC PUBLIC HEALTH, 2024, 24 (01)
  • [3] Digital mental health interventions as stand-alone vs. augmented treatment as usual
    Benjamin W. Nelson
    Nicholas C. Peiper
    Valerie L. Forman-Hoffman
    BMC Public Health, 24
  • [4] Improved incidence estimates from linked vs. stand-alone electronic health records
    Millett, Elizabeth R. C.
    Quint, Jennifer K.
    De Stavola, Bianca L.
    Smeeth, Liam
    Thomas, Sara L.
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2016, 75 : 66 - 69
  • [5] Prolung Electro Pulmonary Nodule (epn) Scan Vs. Pet CT In The Evaluation Of Solitary Pulmonary Nodules (spn)
    Bezzi, M.
    Innocenti, M.
    Trigiani, M.
    Luzzi, V.
    Torricelli, E.
    Leoncini, F.
    Romani, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [6] Performance evaluation of a PET insert for preclinical MRI in stand-alone PET and simultaneous PET–MRI modes
    Gaelle Emvalomenos
    Sofie Trajanovska
    Binh T. T. Pham
    Peter Doughty
    Jerome Burnet
    Isabelle Smith
    Ruslan Garipov
    Marie-Claude Gregoire
    Nana Sunn
    John McGrath
    Steven R. Meikle
    EJNMMI Physics, 8
  • [7] Economic Comparison Between a Stand-Alone and a Grid Connected PV System vs. Grid Distance
    Marino, Concettina
    Nucara, Antonino
    Panzera, Maria Francesca
    Pietrafesa, Matilde
    Pudano, Alfredo
    ENERGIES, 2020, 13 (15)
  • [8] DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study
    Clemens G. Kaiser
    C. Reich
    M. Dietzel
    P. A. T. Baltzer
    J. Krammer
    K. Wasser
    S. O. Schoenberg
    W. A. Kaiser
    European Radiology, 2015, 25 : 1793 - 1800
  • [9] DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study
    Kaiser, Clemens G.
    Reich, C.
    Dietzel, M.
    Baltzer, P. A. T.
    Krammer, J.
    Wasser, K.
    Schoenberg, S. O.
    Kaiser, W. A.
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1793 - 1800
  • [10] Performance evaluation of a PET insert for preclinical MRI in stand-alone PET and simultaneous PET-MRI modes
    Emvalomenos, Gaelle
    Trajanovska, Sofie
    Pham, Binh T. T.
    Doughty, Peter
    Burnet, Jerome
    Smith, Isabelle
    Garipov, Ruslan
    Gregoire, Marie-Claude
    Sunn, Nana
    McGrath, John
    Meikle, Steven R.
    EJNMMI PHYSICS, 2021, 8 (01)