Radiation dose of cone beam CT combined with shape sensing robotic assisted bronchoscopy for the evaluation of pulmonary lesions: an observational single center study

被引:7
|
作者
Styrvoky, Kim [1 ,3 ]
Schwalk, Audra [1 ]
Pham, David [1 ]
Madsen, Kristine [2 ]
Chiu, Hsienchang T. [1 ]
Abu-Hijleh, Muhanned [1 ]
机构
[1] Univ Texas Southwestern Med Ctr, Div Pulm & Crit Care Med, Dallas, TX USA
[2] Univ Texas Southwestern Med Ctr, Dept Internal Med, Dallas, TX USA
[3] Univ Texas Southwestern Med Ctr, Div Pulm & Crit Care Med, 5323 Harry Hines Blvd, Dallas, TX 75219 USA
基金
美国国家卫生研究院;
关键词
Robotic assisted bronchoscopy; navigational bronchoscopy; cone beam computed tomography (CBCT); radiation dose; pulmonary lesion; ELECTROMAGNETIC NAVIGATION BRONCHOSCOPY; LUNG NODULES; BIOPSY; EXPOSURE; GUIDANCE; SAFETY;
D O I
10.21037/jtd-23-587
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Shape sensing robotic assisted bronchoscopy (ssRAB) combined with radial endobronchial ultrasound (r-EBUS) and cone beam computed tomography (CBCT) is a newer diagnostic modality for the evaluation of pulmonary lesions. There is limited data describing the radiation dose of CBCT combined with ssRAB. The purpose of this study was to describe the technical factors associated with the use of CBCT combined with ssRAB to biopsy pulmonary lesions.Methods: We conducted a single center, prospective observational study of patients undergoing ssRAB combined with fixed CBCT for the pulmonary lesion biopsy. We report our patient demographics, and pulmonary lesion and procedure characteristics.Results: A total of 241 ssRAB procedures were performed to biopsy 269 pulmonary lesions. The mean lesion size was measured in the following dimensions: anteroposterior (18.0 & PLUSMN;8.8 mm), transverse (17.2 & PLUSMN;10.5 mm), and craniocaudal (17.7 & PLUSMN;10.2 mm). A mean of 1.5 & PLUSMN;0.7 (median: 1, range: 1-4) CBCT spins were performed. The mean total fluoroscopy time (FT) was 5.6 & PLUSMN;2.9 minutes. The mean radiation dose of cumulative air kerma (CAK) was 63.5 & PLUSMN;46.7 mGy and the mean cumulative dose area product (DAP) was 22.6 & PLUSMN;16.0 Gy & BULL;cm2. Diagnostic yield calculated based on results at index bronchoscopy was 85.9%. There was a low rate of complications with eight pneumothoraces (3.3%), five (2.1%) of which required chest tube placement.Conclusions: We describe the use of ssRAB combined with CBCT to biopsy pulmonary lesions as a safe diagnostic modality with relatively low radiation dose that is potentially comparable to other image guided sampling modalities. Bronchoscopists should be cognizant of the radiation use during the procedure for both patient and staff safety.
引用
收藏
页码:4836 / 4848
页数:13
相关论文
共 32 条
  • [1] INTEGRATION OF SHAPE-SENSING ROBOTIC-ASSISTED BRONCHOSCOPY AND CONE-BEAM CT FOR THE BIOPSY OF PULMONARY NODULES
    Pritchett, Michael
    Muller, Leah
    Ost, David
    Reisenauer, Janani
    Majid, Adnan
    Simoff, Michael
    Keyes, Colleen
    Casal, Roberto
    Parikh, Mihir
    Diaz-Mendoza, Javier
    Fernandez-Bussy, Sebastian
    Folch, Erik
    CHEST, 2021, 160 (04) : 1622A - 1624A
  • [2] DIAGNOSTIC ACCURACY OF ROBOTIC-ASSISTED BRONCHOSCOPY USING SHAPE-SENSING TECHNOLOGY WITH CONE-BEAM CT IMAGING IN EVALUATION OF PULMONARY LESIONS: A RETROSPECTIVE REVIEW
    Madsen, Kristine
    Styrvoky, Kim
    Pham, David T.
    Schwalk, Audra J.
    Chiu, Hsienchang Thomas H. C.
    Rudkovskaia, Anastasiia
    Abu-Hijleh, Muhanned A.
    CHEST, 2022, 162 (04) : 1628A - 1628A
  • [3] Shape-Sensing Robotic-Assisted Bronchoscopy with Concurrent use of Radial Endobronchial Ultrasound and Cone Beam Computed Tomography in the Evaluation of Pulmonary Lesions
    Kim Styrvoky
    Audra Schwalk
    David Pham
    Hsienchang T. Chiu
    Anastasiia Rudkovskaia
    Kristine Madsen
    Stephen Carrio
    Elizabeth M. Kurian
    Luis De Las Casas
    Muhanned Abu-Hijleh
    Lung, 2022, 200 : 755 - 761
  • [4] Shape-Sensing Robotic-Assisted Bronchoscopy with Concurrent use of Radial Endobronchial Ultrasound and Cone Beam Computed Tomography in the Evaluation of Pulmonary Lesions
    Styrvoky, Kim
    Schwalk, Audra
    Pham, David
    Chiu, Hsienchang T.
    Rudkovskaia, Anastasiia
    Madsen, Kristine
    Carrio, Stephen
    Kurian, Elizabeth M.
    De las Casas, Luis
    Abu-Hijleh, Muhanned
    LUNG, 2022, 200 (06) : 755 - 761
  • [5] SHAPE-SENSING ROBOTIC ASSISTED BRONCHOSCOPY FOR THE DIAGNOSIS OF PERIPHERAL PULMONARY LESIONS
    Pritchett, Michael
    Schirmer, Charles
    CHEST, 2021, 160 (04) : 1631A - 1632A
  • [6] Shape-Sensing Robotic-Assisted Bronchoscopy in the Diagnosis of Pulmonary Parenchymal Lesions
    Kalchiem-Dekel, Or
    Connolly, James G.
    Lin, I-Hsin
    Husta, Bryan C.
    Adusumilli, Prasad S.
    Beattie, Jason A.
    Buonocore, Darren J.
    Dycoco, Joseph
    Fuentes, Paige
    Jones, David R.
    Lee, Robert P.
    Park, Bernard J.
    Rocco, Gaetano
    Chawla, Mohit
    Bott, Matthew J.
    CHEST, 2022, 161 (02) : 572 - 582
  • [7] Shape-sensing Robotic-Assisted Bronchoscopy with cone beam CT for the investigation of pulmonary nodules: interim results of the first multicentre European trial
    Chan, Ley Taing
    Orton, Christopher M.
    Temov, Kire
    Tana, Anand
    Baboolal, Ilecia
    Avanzi, Laura
    Dhanji, Al-Rehan
    Karir, Ashish
    Agaoglu, Elif S.
    Garner, Justin L.
    Kalyal, Aisha
    Lapuente, Maria
    Meireles, Ines
    Moore, Jennifer
    Scott, Eleanor
    Pereira, Patricia
    Thomas, Jessica
    Ttofia, Foteini
    Lau, Kelvin
    Shah, Pallav L.
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [8] Evaluation of the Accuracy of Combined Robotic Assisted Bronchoscopy (RAB) and Cone Beam Computed Tomography (CBCT)
    Revelo, A. E.
    Ghattas, C.
    Pannu, J. K.
    Sinha, T.
    Pastis, N. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [9] Impact of Intra-operative Mobile Cone Beam CT on Shape-sensing Robotic-assisted Bronchoscopy: Improving Accuracy
    Menon, A.
    Husta, B.
    Bergemann, R.
    Schmitz, J.
    Adusumilli, P.
    Beattie, J.
    Lee, R.
    Park, B.
    Rocco, G.
    Bott, M.
    Chawla, M.
    Kalchiem-Dekel, O.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [10] CHARACTERIZING DIVERGENCE IN SHAPE-SENSING ROBOTIC-ASSISTED BRONCHOSCOPY INTEGRATED WITH MOBILE CONE-BEAM CT: RESULTS FROM A PROSPECTIVE, MULTICENTER STUDY
    Casal, Roberto F.
    Batra, Hitesh
    Cheng, George Zhi
    Reisenauer, Janani
    Bartek, William
    Zouk, Aline N.
    Kalchiem-Dekel, Or
    Patel, Niral M.
    Oh, Scott S.
    Husta, Bryan C.
    CHEST, 2024, 166 (04) : 6480A - 6481A