共 32 条
Radiation dose of cone beam CT combined with shape sensing robotic assisted bronchoscopy for the evaluation of pulmonary lesions: an observational single center study
被引:7
|作者:
Styrvoky, Kim
[1
,3
]
Schwalk, Audra
[1
]
Pham, David
[1
]
Madsen, Kristine
[2
]
Chiu, Hsienchang T.
[1
]
Abu-Hijleh, Muhanned
[1
]
机构:
[1] Univ Texas Southwestern Med Ctr, Div Pulm & Crit Care Med, Dallas, TX USA
[2] Univ Texas Southwestern Med Ctr, Dept Internal Med, Dallas, TX USA
[3] Univ Texas Southwestern Med Ctr, Div Pulm & Crit Care Med, 5323 Harry Hines Blvd, Dallas, TX 75219 USA
基金:
美国国家卫生研究院;
关键词:
Robotic assisted bronchoscopy;
navigational bronchoscopy;
cone beam computed tomography (CBCT);
radiation dose;
pulmonary lesion;
ELECTROMAGNETIC NAVIGATION BRONCHOSCOPY;
LUNG NODULES;
BIOPSY;
EXPOSURE;
GUIDANCE;
SAFETY;
D O I:
10.21037/jtd-23-587
中图分类号:
R56 [呼吸系及胸部疾病];
学科分类号:
摘要:
Background: Shape sensing robotic assisted bronchoscopy (ssRAB) combined with radial endobronchial ultrasound (r-EBUS) and cone beam computed tomography (CBCT) is a newer diagnostic modality for the evaluation of pulmonary lesions. There is limited data describing the radiation dose of CBCT combined with ssRAB. The purpose of this study was to describe the technical factors associated with the use of CBCT combined with ssRAB to biopsy pulmonary lesions.Methods: We conducted a single center, prospective observational study of patients undergoing ssRAB combined with fixed CBCT for the pulmonary lesion biopsy. We report our patient demographics, and pulmonary lesion and procedure characteristics.Results: A total of 241 ssRAB procedures were performed to biopsy 269 pulmonary lesions. The mean lesion size was measured in the following dimensions: anteroposterior (18.0 & PLUSMN;8.8 mm), transverse (17.2 & PLUSMN;10.5 mm), and craniocaudal (17.7 & PLUSMN;10.2 mm). A mean of 1.5 & PLUSMN;0.7 (median: 1, range: 1-4) CBCT spins were performed. The mean total fluoroscopy time (FT) was 5.6 & PLUSMN;2.9 minutes. The mean radiation dose of cumulative air kerma (CAK) was 63.5 & PLUSMN;46.7 mGy and the mean cumulative dose area product (DAP) was 22.6 & PLUSMN;16.0 Gy & BULL;cm2. Diagnostic yield calculated based on results at index bronchoscopy was 85.9%. There was a low rate of complications with eight pneumothoraces (3.3%), five (2.1%) of which required chest tube placement.Conclusions: We describe the use of ssRAB combined with CBCT to biopsy pulmonary lesions as a safe diagnostic modality with relatively low radiation dose that is potentially comparable to other image guided sampling modalities. Bronchoscopists should be cognizant of the radiation use during the procedure for both patient and staff safety.
引用
收藏
页码:4836 / 4848
页数:13
相关论文