The importance of sampling time in radionuclide measurement of glomerular filtration rate in adults using single blood sample

被引:1
|
作者
Ptacnik, Vaclav [1 ,2 ]
Ters, Jiri [3 ]
Samal, Martin [1 ,2 ]
Stefanova, Klara [3 ]
Vichova, Eva [3 ]
Skibova, Daniela [1 ,2 ]
Mlateckova, Lenka [3 ]
Zogala, David [1 ,2 ]
机构
[1] Charles Univ Prague, Inst Nucl Med, Fac Med 1, Prague, Czech Republic
[2] Gen Univ Hosp Prague, Prague, Czech Republic
[3] Inst Clin & Expt Med, Dept Med Imaging, Prague, Czech Republic
关键词
Plasma clearance; Glomerular filtration rate; Kidney function; Single-sample method; Optimal sampling time; PLASMA-CLEARANCE; RENAL CLEARANCE; EQUATION; GFR; VALIDATION; GUIDELINES; CHILDREN; INFANTS;
D O I
10.1007/s40336-023-00583-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeIn theory, radionuclide measurement of glomerular filtration rate (GFR) using bolus injection and a single blood sample results in GFR values close to the results of slope-intercept (SI) method using two or more blood samples, especially if the sample is collected at specific time. The aim of our study was to provide experimental validation of this assumption, to design the new single-sample methods potentially correcting for inadequate sampling time, and to validate them together with the method recommended by the British Nuclear Medicine Society (BNMS) guidelines.MethodsNew analytic and regression-based single-sample methods were developed using previously published concepts. In 373 patients, GFR measured by the new methods and by the method recommended by the BNMS guidelines was compared with the reference GFR measured by SI method using two blood samples. Prediction of the reference GFR was evaluated by cross-validation with all blood samples and with blood samples collected at time interval & PLUSMN; 30 min around optimal sampling time.ResultsWith all 768 blood samples (regardless of sampling time), the method recommended by the BNMS guidelines performed significantly better than the new methods, predicting reference GFR with the mean absolute error (MAE) of 2.55 (versus 2.95-3.37) ml/min/1.73 m(2). In the subset of blood samples collected at time interval & PLUSMN; 30 min around optimal sampling time derived from SI method (n = 247), performance of all methods was significantly improved. MAE was reduced to 1.18 (vs. 1.27-1.39) ml/min/1.73 m(2). Realistic estimate of optimal sampling time using creatinine prediction equation CKD-EPI (n = 235) resulted in MAE of 1.37 (vs. 1.53-1.76) ml/min/1.73 m(2).ConclusionThe study experimentally confirmed that collection of single blood sample near patient-specific optimal sampling time significantly improves accuracy of prediction of the reference SI GFR by all validated single-sample methods. The method recommended by the BNMS guidelines provided the best results with low prediction error that was further reduced by collecting blood sample at optimal sampling time. The new methods successfully corrected for small deviations from optimal sampling time.
引用
收藏
页码:493 / 504
页数:12
相关论文
共 50 条
  • [1] The importance of sampling time in radionuclide measurement of glomerular filtration rate in adults using single blood sample
    Václav Ptáčník
    Jiří Terš
    Martin Šámal
    Klára Stefanová
    Eva Víchová
    Daniela Skibová
    Lenka Mlatečková
    David Zogala
    Clinical and Translational Imaging, 2023, 11 : 493 - 504
  • [2] Sampe blood volume required for radionuclide glomerular filtration rate (GFR) measurement in adults
    Arsos, G.
    Tsehelidis, I.
    Sakagiannis, G.
    Dogramatzi, F.
    Athanasiadou, Z.
    Psaroyli, E.
    Karakatsanis, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S439 - S439
  • [3] Sampling requirements for radionuclide glomerular filtration rate (GFR) measurement in children
    Arsos, G.
    Sakagiannis, G.
    Tsehelidis, I.
    Athanasiadou, Z.
    Dogramatzi, F.
    Iakovidou, A.
    Psaroyli, E.
    Karakatsanis, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S439 - S440
  • [4] Radionuclide glomerular filtration rate (GFR) measurement after single vs duplicate plasma sample counting
    Arsos, G.
    Tsehelidis, I.
    Sakagiannis, G.
    Athanasiadou, Z.
    Dogramatzi, F.
    Svoukas, A.
    Psaroyli, E.
    Karakatsanis, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S439 - S439
  • [5] Using a Single Blood Sample and Inulin to Estimate Glomerular Filtration Rate in Rabbits
    Michigoshi, Yuuki
    Yamagishi, Norio
    Satoh, Hiroshi
    Kato, Masaki
    Furuhama, Kazuhisa
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2011, 50 (05): : 702 - 707
  • [6] DETERMINATION OF GLOMERULAR FILTRATION RATE BY ANALYSIS OF A SINGLE BLOOD SAMPLE
    SAPIRSTEIN, LA
    PULTZ, AJ
    HERROLD, MR
    AMERICAN JOURNAL OF PHYSIOLOGY, 1952, 171 (03): : 763 - 763
  • [7] Guidelines for the measurement of glomerular filtration rate using plasma sampling
    Piepsz, A
    Ham, R
    De Sadeleer, C
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (02) : 175 - 176
  • [8] Guidelines for the measurement of glomerular filtration rate using plasma sampling
    Fleming, JS
    Zivanovic, MA
    Blake, GM
    Burniston, M
    Cosgriff, PS
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (08) : 759 - 769
  • [9] RADIONUCLIDE MEASUREMENT OF DIFFERENTIAL GLOMERULAR-FILTRATION RATE
    POWERS, TA
    STONE, WJ
    GROVE, RB
    PLUNKETT, JM
    KADIR, S
    PATTON, JA
    BOWEN, RD
    INVESTIGATIVE RADIOLOGY, 1981, 16 (01) : 59 - 64
  • [10] GLOMERULAR FILTRATION RATE [GFR] MEASUREMENT BY SINGLE SAMPLE IOHEXOL CLEARANCE
    Parab, Sachin
    Madraki, R. M.
    Bhusari, S. M.
    Kulkarni, R.
    Thatte, U. M.
    Halankar, A. R.
    Almeida, A. F.
    NEPHROLOGY, 2005, 10 : A143 - A143