A Sensitive Fluorescence Polarization Immunoassay for the Rapid Detection of Okadaic Acid in Environmental Waters

被引:4
|
作者
Hendrickson, Olga D. [1 ]
Mukhametova, Liliya I. [2 ]
Zvereva, Elena A. [1 ]
Zherdev, Anatoly V. [1 ]
Eremin, Sergei A. [1 ,2 ]
机构
[1] Russian Acad Sci, AN Bach Inst Biochem, Res Ctr Biotechnol, Leninsky Prospect 33, Moscow 119071, Russia
[2] Moscow MV Lomonosov State Univ, Fac Chem, Dept Chem Enzymol, Leninskie Gory 1, Moscow 119991, Russia
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 04期
基金
俄罗斯科学基金会;
关键词
fluorescence polarization immunoassay; phycotoxins; okadaic acid; contamination; water safety; COLLOIDAL GOLD IMMUNOASSAY; LINKED-IMMUNOSORBENT-ASSAY; LATERAL FLOW IMMUNOASSAY; MONOCLONAL-ANTIBODY; COMPETITIVE ELISA; RECENT PROGRESS; TOXINS;
D O I
10.3390/bios13040477
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a homogeneous fluorescence polarization immunoassay (FPIA) for the detection of hazardous aquatic toxin okadaic acid (OA) contaminating environmental waters was for the first time developed. A conjugate of the analyte with a fluorophore based on a fluorescein derivative (tracer) was synthesized, and its interaction with specific anti-OA monoclonal antibodies (MAbs) was tested. A MAbs-tracer pair demonstrated highly affine immune binding (KD = 0.8 nM). Under optimal conditions, the limit of OA detection in the FPIA was 0.08 ng/mL (0.1 nM), and the working range of detectable concentrations was 0.4-72.5 ng/mL (0.5-90 nM). The developed FPIA was approbated for the determination of OA in real matrices: river water and seawater samples. No matrix effect of water was observed; therefore, no sample preparation was required before analysis. Due to this factor, the entire analytical procedure took less than 10 min. Using a compact portable fluorescence polarization analyzer enables the on-site testing of water samples. The developed analysis is very fast, easy to operate, and sensitive and can be extended to the determination of other aquatic toxins or low-molecular-weight water or food contaminants.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A Simple, Sensitive, Rapid and Specific Detection Method for Bisphenol A based on Fluorescence Polarization Immunoassay
    Wu, Xiaoling
    Wang, Libing
    Ma, Wei
    Zhu, Yingyue
    Xu, Liguang
    Kuang, Hua
    Xu, Chuanlai
    IMMUNOLOGICAL INVESTIGATIONS, 2012, 41 (01) : 38 - 50
  • [2] Fluorescence Polarization Immunoassay for Rapid, Sensitive Detection of the Herbicide 2,4-Dichlorophenoxyacetic Acid in Juice and Water Samples
    Mukhametova, Liliya I.
    Kolokolova, Marya K.
    Shevchenko, Ivan A.
    Tupertsev, Boris S.
    Zherdev, Anatoly V.
    Xu, Chuanlai
    Eremin, Sergei A.
    Biosensors, 2025, 15 (01):
  • [3] A highly specific and sensitive fluorescence polarization immunoassay for the rapid detection of triazophos residue in agricultural products
    Liu, Ying
    Liu, Rui
    Boroduleva, Anna
    Eremin, Sergei
    Guo, Yirong
    Zhu, Guonian
    ANALYTICAL METHODS, 2016, 8 (36) : 6636 - 6644
  • [4] Rapid Fluorescence Polarization Immunoassay for Highly Sensitive Detection of 2,4,6-Trinitrotoluene
    Lu, Wenzong
    Ni, Yuan
    Jia, Guangfeng
    Pan, Haixian
    Zhao, Chen
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (03) : 773 - 776
  • [5] Sensitive Rapid Fluorescence Polarization Immunoassay for Free Mycophenolic Acid Determination in Human Serum and Plasma
    Glahn-Martinez, Bettina
    Benito-Pena, Elena
    Salis, Francesca
    Descalzo, Ana B.
    Orellana, Guillermo
    Moreno-Bondi, Maria C.
    ANALYTICAL CHEMISTRY, 2018, 90 (08) : 5459 - 5465
  • [6] Fluorescence Polarization Immunoassay for Rapid, Accurate and Sensitive Determination of Ochratoxin A in Wheat
    Lippolis, Vincenzo
    Pascale, Michelangelo
    Valenzano, Stefania
    Porricelli, Anna Chiara Raffaella
    Suman, Michele
    Visconti, Angelo
    FOOD ANALYTICAL METHODS, 2014, 7 (02) : 298 - 307
  • [7] Fluorescence Polarization Immunoassay for Rapid, Accurate and Sensitive Determination of Ochratoxin A in Wheat
    Vincenzo Lippolis
    Michelangelo Pascale
    Stefania Valenzano
    Anna Chiara Raffaella Porricelli
    Michele Suman
    Angelo Visconti
    Food Analytical Methods, 2014, 7 : 298 - 307
  • [8] A fluorescence polarization immunoassay for detection of thiacloprid in environmental and agricultural samples
    Ding, Yuan
    Chen, He
    Yang, Qian
    Feng, Lu
    Hua, Xiude
    Wang, Minghua
    RSC ADVANCES, 2019, 9 (63) : 36825 - 36830
  • [9] Effects of Addition of Blocking Agents on Fluorescence Polarization Immunoassay of Okadaic Acid Using a Microfluidic Device
    Chida, Shunsuke
    Takahashi, Kazuki
    Fukuyama, Mao
    Kasuya, Motohiro
    Maeki, Masatoshi
    Ishida, Akihiko
    Tani, Hirofumi
    Shigemura, Koji
    V. Zherdev, Anatoly
    Eremin, Sergei A.
    Hibara, Akihide
    Tokeshi, Manabu
    BUNSEKI KAGAKU, 2023, 72 (03) : 133 - 138
  • [10] Rapid and sensitive competitive fluorescence immunoassay for the detection of chlortetracycline residues in environment
    Yuan, Ying-xian
    Li, Zhaohui
    Jiao, Gui-zhi
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 1166 - +