Design of Base-Isolated Building as Per Indian Code Provisions and Practices

被引:0
|
作者
Matsagar, Vasant [1 ]
Jain, Ratish [2 ]
机构
[1] Indian Inst Technol IIT Delhi, New Delhi 110016, India
[2] Resistoflex Dynam Private Ltd, 7,Sect 2, Noida 201301, Uttar Pradesh, India
关键词
Base-isolated building; Performance-based earthquake engineering; Indian seismic code provisions; Passive vibration control; Benefit-cost analysis;
D O I
10.1007/978-3-031-21187-4_29
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Detailed design of a base-isolated building as per Indian code provisions and practices is made and described here to facilitate corroboration of the design with other international codes and standards. Upon reviewing the latest developments and applications of the base isolation technology in India, the code development is presented. Particularly, the code provisions and practices in India have been elaborated in light of the state-of-the-art and state-of-the-practice. Then, by taking an example building, base isolation system has been designed and provided to achieve higher seismic performance. Assessment of the design outcomes is made to understand the implications of the code recommendation, especially from techno-economics viewpoints.
引用
收藏
页码:349 / 360
页数:12
相关论文
共 50 条
  • [1] Design considerations for a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 761 - 776
  • [2] Analysis, Design, and Construction of a Base-Isolated Multiple Building Structure
    Sorace, Stefano
    Terenzi, Gloria
    ADVANCES IN CIVIL ENGINEERING, 2014, 2014
  • [3] Comparison of Seismic Response Characteristics Between Non Base-isolated and Base-isolated Building
    Enomoto, Takahisa
    Ninomiya, Masayuki
    Navarro, Manuel
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 2797 - 2804
  • [4] Optimal Design of Nontraditional Tuned Mass Damper for Base-Isolated Building
    Li, Dawei
    Ikago, Kohju
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (10) : 2841 - 2862
  • [5] Seismic performance of a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 777 - 793
  • [6] Experiments on a base-isolated building in Santiago, Chile
    Moroni, MO
    Sarrazin, M
    Boroschek, R
    ENGINEERING STRUCTURES, 1998, 20 (08) : 720 - 725
  • [7] Experiments on a base-isolated building in Santiago, Chile
    Univ of Chile, Santiago, Chile
    Eng Struct, 8 (720-725):
  • [8] λ-Factors for the Upper and Lower Bound Analyses of Base-Isolated Structures: Historical Review of Code Provisions for Elastomeric Bearings
    Ragni, Laura
    Micozzi, Fabio
    Gioiella, Laura
    Castellano, Maria Gabriella
    Infanti, Samuele
    Dall'Asta, Andrea
    APPLIED SCIENCES-BASEL, 2023, 13 (09):
  • [9] Robust active control of hysteretic base-isolated structures: Application to the benchmark smart base-isolated building
    Pozo, Francesc
    Montserrat, Pere Marc
    Rodellar, Jose
    Acho, Leonardo
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 720 - 736
  • [10] Smart system design for a 3D base-isolated benchmark building
    Wang, Yumei
    Dyke, Shirley
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (07): : 939 - 957