Clinical Values of Whole-Body Blood Pool Scans and SPECT for Evaluation of Congenital Vascular Malformation

被引:1
|
作者
Son, Junik [1 ]
Hong, Chae Moon [1 ,2 ]
Lee, Jaetae [1 ,2 ]
Chung, Ho Yun [3 ,4 ,5 ,6 ]
Ahn, Byeong-Cheol [1 ,2 ]
机构
[1] Kyungpook Natl Univ Hosp, Dept Nucl Med, 130 Dongdeok Ro, Daegu 41944, South Korea
[2] Kyungpook Natl Univ, Sch Med, Dept Nucl Med, Daegu, South Korea
[3] Kyungpook Natl Univ Hosp, Vasc Anomalies Ctr, Dept Plast, Daegu, South Korea
[4] Kyungpook Natl Univ Hosp, Vasc Anomalies Ctr, Dept Reconstruct Surg, Daegu, South Korea
[5] Kyungpook Natl Univ, Sch Med, Dept Plast, Daegu, South Korea
[6] Kyungpook Natl Univ, Sch Med, Dept Reconstruct Surg, Daegu, South Korea
关键词
Congenital vascular malformation; Tc-99m-labeled red blood cells; Whole-body blood pool scintigraphy; SPECT/CT; Venous malformation; Lymphatic malformation; ETHANOL SCLEROTHERAPY; VENOUS MALFORMATIONS; SCINTIGRAPHY; DIAGNOSIS; PERFUSION; HEAD; CLASSIFICATION; HEMANGIOMAS; MANAGEMENT;
D O I
10.1007/s13139-023-00835-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study examines the diagnostic potential of whole-body blood pool scintigraphy (WBBPS) using technetium-99 m-labeled red blood cells to detect congenital vascular malformations (CVMs). It aims to compare its efficacy with traditional imaging techniques such as magnetic resonance imaging (MRI) and ultrasonography (USG), emphasizing its potential advantages in terms of characterization of lesions and capacity for whole-body assessment.Methods The efficacy of WBBPS and single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging in diagnosing CVMs, comparing them with USG and MRI results, was evaluated in this retrospective study. Of the 38 patients, 21 were evaluated using these diagnostic methods, with CVMs classified according to the International Society for the Study of Vascular Anomalies guidelines. Also, this study aimed to elucidate the characteristics between WBBPS, SPECT/CT, USG, or MRI findings and their consistency with the final diagnosis.Results A total of 21 participants were included in this study, with an average age of 17.7 years old, with female predominance (57.1%). The most common diagnosis was vascular malformations (VMs) (71.4%), followed by combined vascular malformations (14.3%) and lymphatic malformations (9.5%). WBBPS demonstrated positive results in 95.2% of cases. Distinct imaging patterns for each condition were observed, with WBBPS being crucial in locating lesions.Conclusion The study findings suggested that WBBPS with SPECT/CT could be helpful in detecting occult VM lesions and ruling out a lymphatic malformation diagnosis. Thus, it can be employed in the evaluation of CVMs.
引用
收藏
页码:69 / 80
页数:12
相关论文
共 50 条
  • [1] Clinical Values of Whole-Body Blood Pool Scans and SPECT for Evaluation of Congenital Vascular Malformation
    Junik Son
    Chae Moon Hong
    Jaetae Lee
    Ho Yun Chung
    Byeong-Cheol Ahn
    Nuclear Medicine and Molecular Imaging, 2024, 58 : 69 - 80
  • [2] Evaluation of congenital vascular malformation using whole-body blool pool scintigraphy.
    Choi, JY
    Yoon, JK
    Park, JM
    Kim, DI
    Kim, HH
    Lee, KH
    Kim, SE
    Kim, BT
    Lee, BB
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 165P - 165P
  • [3] Role of whole body blood pool scintigraphy (WBBPS) for management of congenital vascular malformation (CVM)
    Lee, BB
    Kim, HH
    Kim, DI
    Kim, BT
    Choi, JY
    13TH CONGRESS OF THE EUROPEAN CHAPTER OF THE INTERNATIONAL UNION OF ANGIOLOGY, 1999, : 209 - 213
  • [4] CHARACTERIZATION OF CONGENITAL VASCULAR MALFORMATION IN THE EXTREMITIES USING WHOLE BODY BLOOD POOL SCINTIGRAPHY AND LYMPHSCINTIGRAPHY
    Kim, Y. H.
    Choi, J. Y.
    Kim, Y. W.
    Kim, D. I.
    Do, Y. S.
    Hwang, J. H.
    Hyun, S. H.
    Lee, K. -H.
    Kim, B. -T.
    LYMPHOLOGY, 2009, 42 (02) : 77 - 84
  • [5] Clinical usefulness of Whole-Body SPECT/CT
    van Lierop, S.
    Cramer, M.
    Engizek, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S522 - S522
  • [6] EVALUATION OF A CLINICAL WHOLE-BODY COUNTER
    SMITH, EM
    PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (01): : 115 - &
  • [7] Diagnosis and Whole Body Screening Using Blood Pool Scintigraphy for Evaluating Congenital Vascular Malformations
    Kim, Young Hwan
    Choi, Joon Young
    Kim, Young-Wook
    Kim, Dong-Ik
    Do, Young Soo
    Choe, Yearn Seong
    Lee, Kyung-Han
    Kim, Byung-Tae
    ANNALS OF VASCULAR SURGERY, 2014, 28 (03) : 673 - 678
  • [8] Differential diagnosis of congenital venous and lymphovenous malformation using whole body blood pool scintigraphy and lymphoscintigraphy.
    Kim, YH
    Park, JM
    Lee, KH
    Yoon, JK
    Jang, HJ
    Choi, Y
    Choe, YS
    Kim, SE
    Lee, BB
    Kim, BT
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 341P - 341P
  • [9] Clinical Utility of Temporal Subtraction Images in Successive Whole-Body Bone Scans: Evaluation in a Prospective Clinical Study
    Junji Shiraishi
    Daniel Appelbaum
    Yonglin Pu
    Roger Engelmann
    Qiang Li
    Kunio Doi
    Journal of Digital Imaging, 2011, 24 : 680 - 687
  • [10] Whole-body magnetic resonance angiography with blood-pool agents
    Kramer, Harald
    Morana, Giovanni
    EUROPEAN RADIOLOGY, 2007, 17 : B24 - B29