Different Methods for Assessing Tooth Colour-In Vitro Study

被引:4
|
作者
Dias, Susana [1 ]
Dias, Joana [1 ]
Pereira, Ruben [1 ]
Silveira, Joao [1 ,2 ]
Mata, Antonio [1 ,2 ]
Marques, Duarte [1 ,2 ,3 ]
机构
[1] Univ Lisbon, Fac Med Dent, Oral Biol & Biochem Res Grp, P-1950044 Lisbon, Portugal
[2] Univ Lisbon, Fac Med Dent, LIBPhys FCT UID FIS 04559 2013, P-1950044 Lisbon, Portugal
[3] Univ Lisbon, Fac Med Dent, Postgrad Programme Prosthodont, P-1950044 Lisbon, Portugal
关键词
tooth colour; eLAB; SpectroShade; spectrophotometry; photography; RELIABILITY; ACCURACY;
D O I
10.3390/biomimetics8050384
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Colour assessment using digital methods can yield varying results, and it is important for clinicians to recognize the potential variability intra and inter-device. This study aimed to compare the L*a*b* values of VITA Classical (VC) and VITA Toothguide 3D-MASTER (VM) guides using two methods, SpectroShade (SS) and eLAB. Thirty-four measurements per tab were performed by a single operator across three batches of each guide. Intraclass correlation coefficients (ICC) between batches were calculated. Values <0.5, 0.5-0.75, 0.75-0.9, and >0.90 were classified as poor, moderate, good, and excellent reliability, respectively. Results were reported as mean and standard deviation of the L*a*b* values and respective colour differences (Delta E-00) for each tab and method. Statistical analyses were performed with an independent t-test, alpha = 0.05. ICC values between batches were excellent for all L*a*b*, except for a* component in eLAB. There were statistically significant differences between methods in most L*a*b* values. The intra-device mean Delta E-00 was 0.5 +/- 0.6 for VC, 0.5 +/- 0.8 for VM in SS, 1.1 +/- 0.8 for VC, 1.1 +/- 0.9 for VM in eLAB. The mean Delta E-00 inter-device was 4.9 +/- 1.7 for VC, 5.0 +/- 1.7 for VM. Both methods demonstrated good internal consistency, with high ICC values and low intra-device colour differences, but exhibited high variability between methods, higher for a* the component.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Different Methods of Scan Alignment in Erosive Tooth Wear Measurements: An In Vitro Study
    Loumprinis, Nikolaos
    Michou, Stavroula
    Rahiotis, Christos
    [J]. DENTISTRY JOURNAL, 2024, 12 (02)
  • [2] An in vitro comparison of tooth whitening techniques on natural tooth colour
    A. Patel
    C. Louca
    B. J. Millar
    [J]. British Dental Journal, 2008, 204 : E15 - E15
  • [3] Summary of:: An in vitro comparison of tooth whitening techniques on natural tooth colour
    Patel, A.
    Louca, C.
    Millar, B. J.
    [J]. BRITISH DENTAL JOURNAL, 2008, 204 (09) : 516 - 517
  • [4] Effect of Dehydration Time on Tooth Colour Measurement in vitro
    Du, Ruo Xi
    Li, Yi Ming
    Ma, Jian Feng
    [J]. CHINESE JOURNAL OF DENTAL RESEARCH, 2012, 15 (01): : 37 - 39
  • [6] Evaluation of Instrumental Methods for Assessing Colour Fastness
    Kitaguchi, Saori
    Kuramoto, Kanya
    Moridera, Hitomi
    Sato, Tetsuya
    [J]. TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2012, : 846 - 854
  • [7] Evaluation of instrumental methods for assessing colour fastness
    [J]. Kitaguchi, S. (kitaguchi@kit.ac.jp), 2012, Binary Information Press, 65 Weed Ave, Norwalk, CT 06850, United States (05):
  • [8] Methods for Assessing the Colour Fidelity of Light Sources
    Luo, Ming Ronnier
    Li, Hong
    Liu, Xiaoyu
    [J]. 2013 10TH CHINA INTERNATIONAL FORUM ON SOLID STATE LIGHTING (CHINASSL), 2013, : 163 - 165
  • [9] Comparison of different methods of assessing in vitro resistance of Mycobacterium tuberculosis to rifampicin
    Paramasivan, CN
    Rahman, F
    Nalini, S
    Dakshayani, G
    Venkataraman, P
    [J]. INDIAN JOURNAL OF MEDICAL RESEARCH, 2001, 114 : 187 - 191
  • [10] Colour Changes of Tooth-Coloured Materials in the Different Solutions
    Yanikoglu, Nuran
    Duymus, Zeynep Yesil
    Meral, Kadem
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (08) : 6224 - 6230