Evaluating the Thermal Performance and Environmental Impact of Agricultural Greenhouses Using Earth-to-Air Heat Exchanger: An Experimental Study

被引:6
|
作者
Hamdane, Samia [1 ,2 ]
Pires, Luis Carlos Carvalho [2 ,3 ]
Silva, Pedro Dinho [2 ,3 ]
Gaspar, Pedro Dinis [2 ,3 ]
机构
[1] Mohamed Khider Univ, Lab Mech Engn LGM, BP 145 RP, Biskra 07000, Algeria
[2] Univ Beira Interior, Dept Electromech Engn, Rua Marques Avila & Bolama, P-6201001 Covilha, Portugal
[3] C MAST Ctr Mech & Aerosp Sci & Technol, P-6201001 Covilha, Portugal
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 02期
关键词
greenhouse; earth-to-air heat exchanger; CO2; emissions; energy consumption; environmental impact; sustainability; REGION; SYSTEM;
D O I
10.3390/app13021119
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The thermal performance and environmental impact of agricultural greenhouses (GH) connected to earth-to-air heat exchanger (EAHE) systems depend on the ambient temperature, soil temperature, EAHE system, and greenhouse specifications. The impact of an EAHE system on the temperature and humidity of a GH microclimate, as well as its effects on CO2 emissions and heating energy consumption, are determined experimentally. Two scaled-down models of agricultural GHs (2 x 1.4 x 1.4 m(3)) were developed. Each GH was equipped with a heater. A spiral EAHE system was integrated into only one of the GHs. The temperature differences in the microclimate range from 3.5 degrees C to 7.5 degrees C, with the microclimates of GH + EAHE and GH being quite similar. In summary, the EAHE system helped to reduce the hourly energy consumption of the heating system by more than 40%. It also reduced emissions to the environment by more than 100 g (CO2)/hour. The EAHE coefficient of performance (COP) for the cooling mode has a higher average value than that for the heating mode. The closed-loop performed better in cooling mode, while the open-loop performed better in heating mode. When the difference between the set temperature in the heater and the air outlet temperature of the EAHE system is smaller, the heater performs better in reducing energy consumption and CO2 emissions of the heater. The COPheating range is between 0 and 3.4 and the COPcooling range is between 0.5 and 7.3. The energy consumption ranges between 0 and 1.41 kWh and the CO2 emissions are between 0 and 359.55 g. Thus, using EAHE in agricultural greenhouses improves thermal performance and reduces environmental impact, providing an overall benefit in terms of energy consumption and environmental sustainability.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental and numerical research on the thermal performance of a vertical earth-to-air heat exchanger system
    Huang, Kailiang
    Sun, Qihai
    Feng, Guohui
    Zhang, Lei
    Li, Ainong
    Wei, Jiaxing
    Zhang, Xiao
    Meng, Xianghua
    Geothermics, 2025, 125
  • [2] Parametric study on thermal performance of earth-to-air heat exchanger used for cooling of buildings
    Benhammou, Mohammed
    Draoui, Belkacem
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 44 : 348 - 355
  • [3] Thermal performance evaluation of an earth-to-air heat exchanger for the heating mode applications using an experimental test rig
    Ahmad, Saif Nawaz
    Prakash, Om
    ARCHIVES OF THERMODYNAMICS, 2022, 43 (01) : 185 - 207
  • [4] Thermal analysis of earth-to-air heat exchanger using laboratory simulator
    Yusof, T. M.
    Ibrahim, H.
    Azmi, W. H.
    Rejab, M. R. M.
    APPLIED THERMAL ENGINEERING, 2018, 134 : 130 - 140
  • [5] Numerical study of earth-to-air heat exchanger: The effect of thermal insulation
    Xaman, J.
    Hernandez-Perez, I.
    Arce, J.
    Alvarez, G.
    Ramirez-Davila, L.
    Noh-Pat, F.
    ENERGY AND BUILDINGS, 2014, 85 : 356 - 361
  • [6] Experimental and Numerical Study of an Earth-to-Air Heat Exchanger in Northeastern Poland
    Skotnicka-Siepsiak, Aldona
    Wesolowski, Maciej
    Piechocki, Janusz
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (03): : 1255 - 1260
  • [7] Energy and thermal analysis of an innovative earth-to-air heat exchanger: Experimental investigations
    Taurines, Kevin
    Girous-Julien, Stephanie
    Menezo, Christophe
    ENERGY AND BUILDINGS, 2019, 187 : 1 - 15
  • [8] Experimental study of a earth-to-air heat exchanger coupled to a photovoltaic system
    Argiriou, AA
    Lykoudis, SP
    Balaras, CA
    Asimakopoulos, DN
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 620 - 625
  • [10] Evaluation of the thermal performance of an earth-to-air heat exchanger (EAHE) in a harmonic thermal environment
    Yang, Dong
    Guo, Yuanhao
    Zhang, Jinpeng
    ENERGY CONVERSION AND MANAGEMENT, 2016, 109 : 184 - 194