Developing a surface acoustic wave-induced microfluidic cell lysis device for point-of-care DNA amplification

被引:2
|
作者
Husseini, Abbas Ali [1 ]
Yazdani, Ali Mohammad [2 ,3 ]
Ghadiri, Fatemeh [1 ,4 ]
Sisman, Alper [5 ,6 ,7 ,8 ]
机构
[1] Istanbul Gelisim Univ, Life Sci & Biomed Engn Applicat & Res Ctr, Istanbul, Turkiye
[2] Marmara Univ, Fac Engn, Mech Engn Program, Istanbul, Turkiye
[3] Nisantasi Univ, Vocat Sch, Machine Program, Istanbul, Turkiye
[4] Istanbul Univ Cerrahpasa, Dept Comp Engn, Istanbul, Turkiye
[5] Marmara Univ, Fac Engn, Elect & Elect Engn Program, Istanbul, Turkiye
[6] Sabanci Univ, Sabanci Univ Nanotechnol Res & Applicat Ctr SUNUM, Istanbul, Turkiye
[7] Delft Univ Technol, Fac Elect Engn Math & Comp Sci, Delft, Netherlands
[8] Marmara Univ, Fac Engn, Elect & Elect Engn Program, TR-34722 Istanbul, Turkiye
来源
ENGINEERING IN LIFE SCIENCES | 2024年 / 24卷 / 01期
关键词
cell lysis; droplet; micro-glass particle; surface acoustic wave; CHIP;
D O I
10.1002/elsc.202300230
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We developed a microchip device using surface acoustic waves (SAW) and sharp-edge glass microparticles to rapidly lyse low-level cell samples. This microchip features a 13-finger pair interdigital transducer (IDT) with a 30-degree focused angle, creating high-intensity acoustic beams converging 6 mm away at a 16 MHz frequency. Cell lysis is achieved through centrifugal forces acting on Candida albicans cells and glass particles within the focal area. To optimize this SAW-induced streaming, we conducted 42 pilot experiments, varying electrical power, droplet volume, glass particle size, concentration, and lysis time, resulting in optimal conditions: an electrical signal of 2.5 W, a 20 mu L sample volume, glass particle size below 10 mu m, concentration of 0.2 mu g, and a 5-min lysis period. We successfully amplified DNA target fragments directly from the lysate, demonstrating an efficient microchip-based cell lysis method. When combined with an isothermal amplification technique, this technology holds promise for rapid point-of-care (POC) applications.
引用
收藏
页数:13
相关论文
共 22 条
  • [1] Surface acoustic wave-induced precise particle manipulation in a trapezoidal glass microfluidic channel
    Johansson, L.
    Enlund, J.
    Johansson, S.
    Katardjiev, I.
    Wiklund, M.
    Yantchev, V.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (02)
  • [2] Rapid and Sensitive Human-Specific DNA Quantitation Using a Microfluidic Amplification Module at the Point-of-Care
    Tan, Eugene
    Selden, Richard F.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [3] Numerical Investigation of Surface Acoustic Wave (SAW) Interacting with a Droplet for Point-of-Care Devices
    Shah, Imran
    Uddin, Emad
    Mubashar, Aamir
    Sajid, Muhammad
    Younis, Muhammad Yamin
    Samad, Hudair
    Choi, Kyung Hyun
    INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2019, 24 (04): : 632 - 637
  • [4] Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor
    Chen, Xi
    Wang, Meng
    Zhao, Gang
    ACS SENSORS, 2020, 5 (01): : 282 - 291
  • [5] Electromechanical cell lysis using a portable audio device: enabling challenging sample preparation at the point-of-care
    Buser, J. R.
    Wollen, A.
    Heiniger, E. K.
    Byrnes, S. A.
    Kauffman, P. C.
    Ladd, P. D.
    Yager, P.
    LAB ON A CHIP, 2015, 15 (09) : 1994 - 1997
  • [6] Thermal analysis of loop mediated isothermal DNA amplification (LAMP) based point-of-care diagnostic device
    Das, Debayan
    Panigrahi, P. K.
    APPLIED THERMAL ENGINEERING, 2021, 183
  • [7] A low cost point-of-care viscous sample preparation device for molecular diagnosis in the developing world; an example of microfluidic origami
    Govindarajan, A. V.
    Ramachandran, S.
    Vigil, G. D.
    Yager, P.
    Boehringer, K. F.
    LAB ON A CHIP, 2012, 12 (01) : 174 - 181
  • [8] Minimal microfabrication required digital microfluidic system toward point-of-care nucleic acid amplification test application for developing countries
    Thien Hoang
    Bao-Han Ly
    Thanh-Xuan Le
    Thanh-Thao Huynh
    Hoang-Tuan Nguyen
    Toi Van Vo
    Thi Thu Hien Pham
    Khon Huynh
    Microsystem Technologies, 2020, 26 : 1863 - 1873
  • [9] Minimal microfabrication required digital microfluidic system toward point-of-care nucleic acid amplification test application for developing countries
    Thien Hoang
    Bao-Han Ly
    Thanh-Xuan Le
    Thanh-Thao Huynh
    Hoang-Tuan Nguyen
    Toi Van Vo
    Thi Thu Hien Pham
    Khon Huynh
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2020, 26 (06): : 1863 - 1873
  • [10] Application of Shear Horizontal Surface Acoustic Wave (SH-SAW) Immunosensor in Point-of-Care Diagnosis
    Cheng, Chia-Hsuan
    Yatsuda, Hiromi
    Goto, Mikihiro
    Kondoh, Jun
    Liu, Szu-Heng
    Wang, Robert Y. L.
    BIOSENSORS-BASEL, 2023, 13 (06):