Development and validation of MonteRay, a fast Monte Carlo dose engine for carbon ion beam radiotherapy

被引:7
|
作者
Lysakovski, Peter [1 ,2 ]
Kopp, Benedikt [1 ]
Tessonnier, Thomas [1 ,3 ]
Mein, Stewart [1 ,3 ,4 ,5 ,6 ,7 ,8 ]
Ferrari, Alfredo [1 ]
Haberer, Thomas [1 ]
Debus, Juergen [1 ,4 ,7 ,9 ]
Mairani, Andrea [1 ,3 ,4 ,10 ]
机构
[1] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Dept Radiat Oncol, Heidelberg, Germany
[2] Heidelberg Univ, Fac Phys & Astron, Heidelberg, Germany
[3] Heidelberg Univ Hosp UKHD, German Canc Consortium DKTK, Natl Ctr Tumor Dis NCT, Clin Cooperat Unit Translat Radiat Oncol,Core Ctr, Heidelberg, Germany
[4] German Canc Res Ctr, Heidelberg, Germany
[5] Heidelberg Univ Hosp UKHD, Heidelberg Fac Med MFHD, Div Mol & Translat Radiat Oncol, Heidelberg, Germany
[6] Heidelberg Univ Hosp UKHD, Dept Radiat Oncol, Heidelberg, Germany
[7] Heidelberg Univ Hosp UKHD, Heidelberg Fac Med MFHD, Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Oncol NCRO, Heidelberg, Germany
[8] Univ Penn, Dept Radiat Oncol, Philadelphia, PA USA
[9] Heidelberg Univ Hosp UKHD, Clin Cooperat Unit Radiat Oncol, German Canc Consortium DKTK, Core Ctr Heidelberg,Natl Ctr Tumor Dis NCT,Dept Ra, Heidelberg, Germany
[10] Natl Ctr Oncol Hadrontherapy CNAO, Med Phys, Pavia, Italy
关键词
carbon ions; dose calculation; fast Monte Carlo; radiotherapy; SCANNED PROTON; FLUKA; SIMULATIONS; THERAPY; DISTRIBUTIONS; TRANSPORT; ENERGY; GEANT4; SYSTEM; MODEL;
D O I
10.1002/mp.16754
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMonte Carlo (MC) simulations are considered the gold-standard for accuracy in radiotherapy dose calculation; so far however, no commercial treatment planning system (TPS) provides a fast MC for supporting clinical practice in carbon ion therapy.PurposeTo extend and validate the in-house developed fast MC dose engine MonteRay for carbon ion therapy, including physical and biological dose calculation.MethodsMonteRay is a CPU MC dose calculation engine written in C++ that is capable of simulating therapeutic proton, helium and carbon ion beams. In this work, development steps taken to include carbon ions in MonteRay are presented. Dose distributions computed with MonteRay are evaluated using a comprehensive validation dataset, including various measurements (pristine Bragg peaks, spread out Bragg peaks in water and behind an anthropomorphic phantom) and simulations of a patient plan. The latter includes both physical and biological dose comparisons. Runtimes of MonteRay were evaluated against those of FLUKA MC on a standard benchmark problem.ResultsDosimetric comparisons between MonteRay and measurements demonstrated good agreement. In terms of pristine Bragg peaks, mean errors between simulated and measured integral depth dose distributions were between -2.3% and +2.7%. Comparing SOBPs at 5, 12.5 and 20 cm depth, mean absolute relative dose differences were 0.9%, 0.7% and 1.6% respectively. Comparison against measurements behind an anthropomorphic head phantom revealed mean absolute dose differences of 1.2%& PLUSMN;1.1%$1.2\% \pm 1.1\;\% \;$with global 3%/3 mm 3D-& gamma; passing rates of 99.3%, comparable to those previously reached with FLUKA (98.9%). Comparisons against dose predictions computed with the clinical treatment planning tool RayStation 11B for a meningioma patient plan revealed excellent local 1%/1 mm 3D-& gamma; passing rates of 98% for physical and 94% for biological dose. In terms of runtime, MonteRay achieved speedups against reference FLUKA simulations ranging from 14x to 72x, depending on the beam's energy and the step size chosen.ConclusionsValidations against clinical dosimetric measurements in homogeneous and heterogeneous scenarios and clinical TPS calculations have proven the validity of the physical models implemented in MonteRay. To conclude, MonteRay is viable as a fast secondary MC engine for supporting clinical practice in proton, helium and carbon ion radiotherapy.
引用
收藏
页码:1433 / 1449
页数:17
相关论文
共 50 条
  • [1] Development and benchmarking of the first fast Monte Carlo engine for helium ion beam dose calculation: MonteRay
    Lysakovski, Peter
    Besuglow, Judith
    Kopp, Benedikt
    Mein, Stewart
    Tessonnier, Thomas
    Ferrari, Alfredo
    Haberer, Thomas
    Debus, Juergen
    Mairani, Andrea
    MEDICAL PHYSICS, 2023, 50 (04) : 2510 - 2524
  • [2] Development and validation of an automatic commissioning tool for the Monte Carlo dose engine in myQA iON
    Cohilis, M.
    Hong, L.
    Janssens, G.
    Rossomme, S.
    Sterpin, E.
    Lee, J. A.
    Souris, K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 95 : 1 - 8
  • [3] ORANGE: a Monte Carlo dose engine for radiotherapy
    van der Zee, W
    Hogenbirk, A
    van der Marck, SC
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (04): : 625 - 641
  • [4] Deep learning-based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy
    Zhang, Xinyang
    Zhang, Hui
    Wang, Jian
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Rui
    He, Pengbo
    Li, Qiang
    MEDICAL PHYSICS, 2023, 50 (12) : 7314 - 7323
  • [5] A Fast Monte Carlo Dose Engine for Gamma Knife
    Song, T.
    Li, Y.
    Zhou, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3548 - 3548
  • [6] Monte Carlo Finite-Size Pencil Beam Dose Calculation Engine for Accurate Radiotherapy
    Zheng, H.
    Wang, H.
    Cao, R.
    Song, J.
    He, T.
    Wu, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2924 - 2924
  • [7] Development of An Ultra-Fast Monte Carlo Dose Engine for High Dose Rate Brachytherapy
    Tian, Z.
    Zhang, M.
    Hrycushko, B.
    Stojadinovic, S.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 488 - 488
  • [8] Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations
    Davidson, Scott E.
    Cui, Jing
    Kry, Stephen
    Deasy, Joseph O.
    Ibbott, Geoffrey S.
    Vicic, Milos
    White, R. Allen
    Followill, David S.
    MEDICAL PHYSICS, 2016, 43 (08) : 4842 - 4853
  • [9] Fast Monte Carlo for ion beam analysis simulations
    Schiettekatte, Francois
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (08): : 1880 - 1885
  • [10] Monte Carlo Investigation of Dose Enhancement Due to Nanoparticles in Carbon Ion Beam Therapy
    Ahn, S.
    Jo, K.
    Han, Y.
    Park, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 3116 - 3116