Optimal Design of Array Coils for Multi-Target Adjustable Electromagnetic Brain Stimulation System

被引:1
|
作者
Wang, Tingyu [1 ,2 ]
Yan, Lele [1 ,2 ]
Yang, Xinsheng [1 ,2 ]
Geng, Duyan [1 ,2 ]
Xu, Guizhi [1 ,2 ]
Wang, Alan [3 ,4 ,5 ]
机构
[1] Hebei Univ Technol, Sch Elect Engn, Tianjin 300130, Peoples R China
[2] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equipm, Tianjin 300130, Peoples R China
[3] Univ Auckland, Auckland Bioengn Inst, Auckland 1010, New Zealand
[4] Univ Auckland, Fac Med & Hlth Sci, Ctr Brain Res, Auckland 1010, New Zealand
[5] Univ Auckland, Fac Med & Hlth Sci, Ctr Med Imaging, Auckland 1010, New Zealand
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 05期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
temporal interference; transcranial magnetic stimulation; deep brain stimulation; array coils; electric field;
D O I
10.3390/bioengineering10050568
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Temporal interference magnetic stimulation is a novel noninvasive deep brain neuromodulation technology that can solve the problem of balance between focus area and stimulation depth. However, at present, the stimulation target of this technology is relatively single, and it is difficult to realize the coordinated stimulation of multiple brain regions, which limits its application in the modulation of multiple nodes in the brain network. This paper first proposes a multi-target temporal interference magnetic stimulation system with array coils. The array coils are composed of seven coil units with an outer radius of 25 mm, and the spacing between coil units is 2 mm. Secondly, models of human tissue fluid and the human brain sphere are established. Finally, the relationship between the movement of the focus area and the amplitude ratio of the difference frequency excitation sources under time interference is discussed. The results show that in the case of a ratio of 1:5, the peak position of the amplitude modulation intensity of the induced electric field has moved 45 mm; that is, the movement of the focus area is related to the amplitude ratio of the difference frequency excitation sources. The conclusion is that multi-target temporal interference magnetic stimulation with array coils can simultaneously stimulate multiple network nodes in the brain region; rough positioning can be performed by controlling the conduction of different coils, fine-tuning the position by changing the current ratio of the conduction coils, and realizing accurate stimulation of multiple targets in the brain area.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Multi-target field control for matrix gradient coils
    Hongyan He
    Shufeng Wei
    Huixian Wang
    Wenhui Yang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2024, 37 : 185 - 198
  • [2] Multi-target field control for matrix gradient coils
    He, Hongyan
    Wei, Shufeng
    Wang, Huixian
    Yang, Wenhui
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (02) : 185 - 198
  • [3] Optimal Detectors for Multi-Target Environments
    Rossler, Carl W.
    Minardi, Michael J.
    Ertin, Emre
    Moses, Randolph L.
    2012 IEEE RADAR CONFERENCE (RADAR), 2012,
  • [4] Multi-target Signal Processing in FMCW Radar System with Antenna Array
    Cheng, Kai-Wen
    Su, Hsuan-Jung
    2008 IEEE RADAR CONFERENCE, VOLS. 1-4, 2008, : 1854 - 1858
  • [5] Optimal Signal/Filter Design for Multi-Target Detection in Colored Noise
    Patton, Lee K.
    Rigling, Brian D.
    2011 IEEE RADAR CONFERENCE (RADAR), 2011, : 276 - 281
  • [6] Design and Test of Geodesic Dome Phased Array System for Multi-target TT&C and Communication
    Guangxi, E.
    Yang Hongjun
    2016 15TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS AND NETWORKS (ICOCN), 2016,
  • [7] A neurostimulator system for real, sham, and multi-target transcranial magnetic stimulation
    Sorkhabi, Majid Memarian
    Denison, Timothy
    JOURNAL OF NEURAL ENGINEERING, 2022, 19 (02)
  • [8] Optimal design of the coils of an electromagnetic flow meter
    Michalski, A
    Starzynski, J
    Wincenciak, S
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 2563 - 2566
  • [9] Hardware Architecture Design of Multi-Target Detection and Tracking System
    Wang, Shuhui
    Lu, Xiaofeng
    Wang, Qiaoyuan
    Wei, Longping
    Huang, Rui
    ELECTRICAL AND CONTROL ENGINEERING & MATERIALS SCIENCE AND MANUFACTURING, 2016, : 241 - 247
  • [10] In-Silico Approaches to Multi-target Drug DiscoveryComputer Aided Multi-target Drug Design, Multi-target Virtual Screening
    Xiao Hua Ma
    Zhe Shi
    Chunyan Tan
    Yuyang Jiang
    Mei Lin Go
    Boon Chuan Low
    Yu Zong Chen
    Pharmaceutical Research, 2010, 27 (5) : 739 - 749