Transient stability versus damping of electromechanical oscillations in power systems with embedded multi-terminal VSC-HVDC systems

被引:0
|
作者
Renedo, Javier [1 ]
Rouco, Luis [2 ]
Garcia-Cerrada, Aurelio [2 ]
Sigrist, Lukas [2 ]
机构
[1] Univ Pontificia Comillas, ETSI ICAI, Madrid, Spain
[2] Univ Pontificia Comillas, Inst Invest Tecnol IIT, ETSI ICAI, Madrid, Spain
关键词
HVDC and power electronics; power system stability; power system transient stability; MTDC MODEL; GRIDS; ENHANCEMENT; DC; COORDINATION; DESIGN;
D O I
10.1049/gtd2.12874
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multi-terminal high-voltage direct current technology based on voltage-source converter stations (VSC-MTDC) is expected to be one of the most important contributors to the future of electric power systems. In fact, among other features, it has already been shown how this technology can contribute to improve transient stability in power systems by the use of supplementary controllers. Along this line, this paper will investigate in detail how these supplementary controllers affect electromechanical oscillations, by means of small-signal stability analysis. The paper analyses two control strategies based on the modulation of active-power injections (P-WAF) and reactive-power injections (Q-WAF) in the VSC stations which were presented in previous work. Both control strategies use global signals of the frequencies of the VSC-MTDC system and they presented significant improvements on transient stability. The paper will provide guidelines for the design of these type of controllers to improve both large- and small-disturbance angle stability. Small-signal stability analysis (in Matlab) has been compared with non-linear time domain simulation (in PSS/E) to confirm the results using CIGRE Nordic32A benchmark test system with a VSC-MTDC system. The paper analyses the impact of the controller gains and communication latency on electromechanical-oscillation damping. The main conclusion of the paper is that transient-stability-tailored supplementary controllers in VSC-MTDC systems can be tuned to damp inter-area oscillations too, maintaining their effectiveness.
引用
收藏
页码:3477 / 3487
页数:11
相关论文
共 50 条
  • [1] Reactive-Power Coordination in VSC-HVDC Multi-Terminal Systems for Transient Stability Improvement
    Renedo, Javier
    Garcia-Cerrada, Aurelio
    Rouco, Luis
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (05) : 3758 - 3767
  • [2] Coordinated Design of Supplementary Controllers in VSC-HVDC Multi-Terminal Systems to Damp Electromechanical Oscillations
    Renedo, Javier
    Garcia-Cerrada, Aurelio
    Rouco, Luis
    Sigrist, Lukas
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (01) : 712 - 721
  • [3] Transient Stability Analysis in Multi-Terminal VSC-HVDC Grids
    Endegnanew, A. G.
    Uhlen, K.
    Haileselassie, T. M.
    Anaya-Lara, O.
    [J]. 2016 POWER SYSTEMS COMPUTATION CONFERENCE (PSCC), 2016,
  • [4] Real power regulation design for multi-terminal VSC-HVDC systems
    Li, Guo-Jie
    Ruan, Si-Ye
    Lie, Tek Tjing
    [J]. OPEN ENGINEERING, 2013, 3 (02): : 243 - 252
  • [5] Computationally Efficient Transient Stability Modeling of multi-terminal VSC-HVDC
    van der Meer, Arjen. A.
    Rueda-Torres, Jose
    da Silva, Filipe Faria
    Gibescu, M.
    van der Meijden, Mart A. A. M.
    [J]. 2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [6] A novel power-flow model of multi-terminal VSC-HVDC systems
    Khan, Shagufta
    Bhowmick, Suman
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2016, 133 : 219 - 227
  • [7] Active Power Control Strategies for Transient Stability Enhancement of AC/DC Grids With VSC-HVDC Multi-Terminal Systems
    Renedo, Javier
    Garcia-Cerrada, Aurelio
    Rouco, Luis
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (06) : 4595 - 4604
  • [8] A Protection Scheme for Multi-Terminal VSC-HVDC Transmission Systems
    Raza, Ali
    Akhtar, Amin
    Jamil, Mohsin
    Abbas, Ghulam
    Gilani, Syed Omer
    Liu Yuchao
    Khan, Muhammad Nasir
    Izhar, Tahir
    Xu Dianguo
    Williams, Barry W.
    [J]. IEEE ACCESS, 2018, 6 : 3159 - 3166
  • [9] Coordinated Control in VSC-HVDC Multi-Terminal Systems to Improve Transient Stability: The Impact of Communication Latency
    Renedo, Javier
    Garcia-Cerrada, Aurelio
    Rouco, Luis
    Sigrist, Lukas
    [J]. ENERGIES, 2019, 12 (19)
  • [10] A communication-free reactive-power control strategy in VSC-HVDC multi-terminal systems to improve transient stability
    Renedo, Javier
    Rouco, Luis
    Garcia-Cerrada, Aurelio
    Sigrist, Lukas
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2019, 174