Impact forces in backward falls: Subject-specific video-based rigid body simulation of backward falls

被引:0
|
作者
Khorami, Fatemeh [1 ,2 ]
Obaid, Numaira [1 ,2 ]
Bhatnagar, Tim [3 ]
Ayoub, Ahmed [1 ]
Robinovitch, Steve N. [4 ]
Sparrey, Carolyn J. [1 ,2 ,5 ]
机构
[1] Simon Fraser Univ, Mechatron Syst Engn, Surrey, BC, Canada
[2] Int Collaborat Repair Discoveries ICORD, Vancouver, BC, Canada
[3] Univ British Columbia, Orthopaed, Vancouver, BC, Canada
[4] Simon Fraser Univ, Biomed Physiol & Kinesiol, Burnaby, BC, Canada
[5] Simon Fraser Univ, Mechatron Syst Engn, 250,13450 102 Ave, Surrey, BC V3T 0A3, Canada
基金
加拿大健康研究院;
关键词
Fall; rigid body dynamics; Madymo; older adults' fall; joint stiffness; BONE-MINERAL DENSITY; MULTIBODY DYNAMICS ANALYSIS; PROXIMAL FEMUR; ELDERLY-PEOPLE; HIP FRACTURE; IN-VITRO; STRENGTH; RECONSTRUCTION; INJURY; MODEL;
D O I
10.1177/09544119231207653
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A critical missing component in the study of real-world falls is the ability to accurately determine impact forces resulting from the fall. Subject-specific rigid body dynamic (RBD) models calibrated to video captured falls can quantify impact forces and provide additional insights into injury risk factors. RBD models were developed based on five backward falls captured on surveillance video in long-term care facilities in British Columbia, Canada. Model joint stiffness and initial velocities were calibrated to match the kinematics of the fall and contact forces were calculated. The effect of joint stiffnesses (neck, lumbar spine, hip, and knee joint) on head contact forces were determined by modifying the calibrated stiffness values +/- 25%. Fall duration, fall trajectories, and maximum velocities showed a close match between fall events and simulations. The maximum value of pelvic velocity difference between Kinovea (an open-source software 2D digitization software) and Madymo multibody modeling was found to be 6% +/- 21.58%. Our results demonstrate that neck and hip stiffness values have a non-significant yet large effect on head contact force (t(3) = 1, p = 0.387 and t(3) = 2, p = 0.138), while lower effects were observed for knee stiffness, and the effect of lumbar spine stiffness was negligible. The subject-specific fall simulations constructed from real world video captured falls allow for direct quantification of force outcomes of falls and may have applications in improving the assessment of fall-induced injury risks and injury prevention methods. Graphical abstract
引用
收藏
页码:1275 / 1286
页数:12
相关论文
共 4 条
  • [1] Peak vertical impact forces during backward falls onto the buttocks and the influence of compliant flooring
    Sran, M. M.
    Robinovitch, S. N.
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 : S463 - S463
  • [2] Computer simulation of the loads on the ACL during backward falls based on an open kinematic chain model
    Webster, JD
    Brown, CA
    [J]. SKIING TRAUMA AND SAFETY: TENTH VOLUME, 1996, 1266 : 254 - 269
  • [3] Preventing fall-related vertebral fractures - Effect of floor stiffness on peak impact forces during backward falls
    Sran, Meena M.
    Robinovitch, Stephen N.
    [J]. SPINE, 2008, 33 (17) : 1856 - 1862
  • [4] Subject-specific measures of Achilles tendon moment arm using ultrasound and video-based motion capture
    Manal, Kurt
    Cowder, Justin D.
    Buchanan, Thomas S.
    [J]. PHYSIOLOGICAL REPORTS, 2013, 1 (06): : 1 - 8