Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent

被引:3
|
作者
Amato, Carlo [1 ,2 ]
Susenburger, Markus [1 ,3 ]
Lehr, Samuel [1 ,3 ]
Kuntz, Jan [1 ]
Gehrke, Nicole [4 ]
Franke, Danielle [4 ]
Thuering, Thomas [5 ]
Briel, Andreas [4 ]
Broennimann, Christian [5 ]
Kachelriess, Marc [1 ,2 ]
Sawall, Stefan [1 ,2 ]
机构
[1] German Canc Res Ctr, Div Xray Imaging & Computed Tomog, D-69120 Heidelberg, Germany
[2] Ruprecht Karls Univ Heidelberg, Med Fac, D-69120 Heidelberg, Germany
[3] Ruprecht Karls Univ Heidelberg, Dept Phys & Astron, D-69120 Heidelberg, Germany
[4] nanoPET Pharma GmbH, D-10115 Berlin, Germany
[5] DECTRIS Ltd, CH-5405 Baden, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 13期
关键词
photon-counting computed-tomography; micro-CT; high-Z nanoparticles; multi-contrast agent protocol; material decomposition; COMPUTED-TOMOGRAPHY;
D O I
10.1088/1361-6560/acdb42
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives. To characterize for the first time in vivo a novel bismuth-based nanoparticular contrast agent developed for preclinical applications. Then, to design and test in vivo a multi-contrast protocol for functional cardiac imaging using the new bismuth nanoparticles and a well-established iodine-based contrast agent. Approach. A micro-computed tomography scanner was assembled and equipped with a photon-counting detector. Five mice were administered with the bismuth-based contrast agent and systematically scanned over 5 h to quantify the contrast enhancement in relevant organs of interest. Subsequently, the multi-contrast agent protocol was tested on three mice. Material decomposition was performed on the acquired spectral data to quantify the concentration of bismuth and iodine in multiple structures, e.g. the myocardium and vasculature. Main results. In the vasculature, the bismuth agent provides a peak enhancement of 1100 HU and a half-life of about 260 min. After the injection, it accumulates in the liver, spleen and intestinal wall reaching a CT value of 440 HU about 5 h post injection. Phantom measurements showed that the bismuth provides more contrast enhancement than iodine for a variety of tube voltages. The multi-contrast protocol for cardiac imaging successfully allowed the simultaneous decomposition of the vasculature, the brown adipose tissue and the myocardium. Significance. The new bismuth-based contrast agent was proven to have a long circulation time suitable for preclinical applications and to provide more contrast than iodine agents. The proposed multi-contrast protocol resulted in a new tool for cardiac functional imaging. Furthermore, thanks to the contrast enhancement provided in the intestinal wall, the novel contrast agent may be used to develop further multi contrast agent protocols for abdominal and oncological imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT
    Ataei, Afrouz
    Vasan, Vasantha
    Soesbe, Todd C.
    Brewington, Cecelia C.
    Zhou, Zhongxing
    Yu, Lifeng
    Hallam, Kristina A.
    Ren, Liqiang
    SENSORS, 2024, 24 (11)
  • [2] Dual-contrast agent photon-counting computed tomography of the heart: initial experience
    Rolf Symons
    Tyler E. Cork
    Manu N. Lakshmanan
    Robert Evers
    Cynthia Davies-Venn
    Kelly A. Rice
    Marvin L. Thomas
    Chia-Ying Liu
    Steffen Kappler
    Stefan Ulzheimer
    Veit Sandfort
    David A. Bluemke
    Amir Pourmorteza
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1253 - 1261
  • [3] Dual-contrast agent photon-counting computed tomography of the heart: initial experience
    Symons, Rolf
    Cork, Tyler E.
    Lakshmanan, Manu N.
    Evers, Robert
    Davies-Venn, Cynthia
    Rice, Kelly A.
    Thomas, Marvin L.
    Liu, Chia-Ying
    Kappler, Steffen
    Ulzheimer, Stefan
    Sandfort, Veit
    Bluemke, David A.
    Pourmorteza, Amir
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (08): : 1253 - 1261
  • [4] A Method for Assessing Confidence of Dual-Contrast Photon-Counting CT Material Quantification
    Leary, C.
    Griglock, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E508 - E509
  • [5] Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography
    Muenzel, Daniela
    Bar-Ness, Daniel
    Roessl, Ewald
    Blevis, Ira
    Bartels, Matthias
    Fingerle, Alexander A.
    Ruschke, Stefan
    Coulon, Philippe
    Daerr, Heiner
    Kopp, Felix K.
    Brendel, Bernhard
    Thran, Axel
    Rokni, Michal
    Herzen, Julia
    Boussel, Loic
    Pfeiffer, Franz
    Proksa, Roland
    Rummeny, Ernst J.
    Douek, Philippe
    Noel, Peter B.
    RADIOLOGY, 2017, 283 (03) : 722 - 727
  • [6] Photon Counting CT of the liver with dual-contrast enhancement
    Muenzel, Daniela
    Proksa, Roland
    Daerr, Heiner
    Fingerle, Alexander A.
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Noel, Peter B.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [7] Contrast-enhanced photon-counting micro-CT of tumor xenograft models
    Li, Mengzhou
    Guo, Xiaodong
    Verma, Amit
    Rudkouskaya, Alena
    Mckenna, Antigone M.
    Intes, Xavier
    Wang, Ge
    Barroso, Margarida
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (15):
  • [8] Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography An Exploratory Animal Study
    Ren, Liqiang
    Huber, Nathan
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 122 - 129
  • [9] Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health
    Paakkari, Petri
    Inkinen, Satu I.
    Jantti, Jiri
    Tuppurainen, Juuso
    Fugazzola, Maria C.
    Joenathan, Anisha
    Ylisiurua, Sampo
    Nieminen, Miika T.
    Kroger, Heikki
    Mikkonen, Santtu
    van Weeren, Rene
    Snyder, Brian D.
    Toyras, Juha
    Honkanen, Miitu K. M.
    Matikka, Hanna
    Grinstaff, Mark W.
    Honkanen, Juuso T. J.
    Makela, Janne T. A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2025,
  • [10] Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography A Feasibility Animal Study
    Ren, Liqiang
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    INVESTIGATIVE RADIOLOGY, 2020, 55 (10) : 688 - 694