Numerical analysis of thermal performance of breathing air cooler based on granular phase change material

被引:0
|
作者
Fetsov, Sergey S. [1 ,2 ]
Lutsenko, Nickolay A. [1 ,2 ]
机构
[1] RAS, Inst Automat & Control Proc, Far Eastern Branch, 5 Radio St, Vladivostok 690041, Russia
[2] Far Eastern Fed Univ, 8 Sukhanova St, Vladivostok 690950, Russia
基金
俄罗斯科学基金会;
关键词
Phase change materials; Packed bed; Breathing air cooler; Computational fluid dynamics; Fire safety; ENERGY-STORAGE-SYSTEM; HEAT-TRANSFER; INHALATION INJURY; BED; PCM; TANK; SIMULATION; SHAPE;
D O I
10.1016/j.ijheatmasstransfer.2024.125288
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, we propose to use granular phase change material (PCM) as a heat accumulating material in a thermal protective respirator also called a heat exchanger to cool the breathing air. Such device is needed to protect human respiratory system from thermal injuries at indoor fires. Using the original solver for OpenFOAM software developed and validated previously, the ability of the commercially available granular PCM in the respirator to cool hot air for breathing during the time required for the human evacuation has been shown numerically: mass of 130 g is enough to cool the air from 177 degrees C to a temperature of less than 50 degrees C within 10 min. This result gives hope that such cooling element can be combined with "conventional" gas-and-smoke protective element, resulting in the creation of respirators for the protection of a person from both hot air and toxic combustion products. A parametric study of the performance of the thermal protective respirator is carried out in the paper: effect of PCM melting temperature, time variation of the outlet air flow rate and partial closure of the outlet from the cooling element have been analyzed. It has been shown that an increase in the PCM melting temperature while keeping the other parameters unchanged worsens the thermal performance of the breathing air cooler. The cooling efficiency is also worsened when the cooling element is narrowed or its outlet is partially closed, as this leads to an increase in the maximum temperature of the inhaled air. It has been shown that the time variation of the inhaled air flow rate, which is used in the calculations of the thermal protective respirator, must be close to the parameters of real human breathing, and the use of the assumption of constant air flow rate is unacceptable, since this can significantly affect the output characteristics of the respirator.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Numerical optimization of a thermal performance of a phase change material based heat sink
    Faraji, Mustapha
    El Qarnia, Hamid
    International Journal of Heat and Technology, 2008, 26 (02) : 17 - 24
  • [2] Thermal performance of phase change material embedded in building Wall- a numerical analysis
    Gopinath, G. R.
    Muthuvel, S.
    Dinesh, N.
    Karthikeyan, G.
    Haashim, A.
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 712 - 716
  • [3] Thermal Performance Evaluation of a Phase Change Material Based Heat Sink : A Numerical Study
    Thomas, Jesto
    Srivatsa, P. V. S. S.
    Krishnan, Ramesh S.
    Baby, Rajesh
    1ST GLOBAL COLLOQUIUM ON RECENT ADVANCEMENTS AND EFFECTUAL RESEARCHES IN ENGINEERING, SCIENCE AND TECHNOLOGY - RAEREST 2016, 2016, 25 : 1182 - 1190
  • [4] Experimental and numerical investigation on composite phase change material (PCM) based heat exchanger for breathing air cooling
    Zhu, Yuan
    Xiao, Jie
    Chen, Tinghan
    Chen, Anqi
    Zhou, Shaoxin
    Liu, Zhiyuan
    Xia, Zhaofan
    APPLIED THERMAL ENGINEERING, 2019, 155 : 631 - 636
  • [5] Numerical investigation on transient thermal performance predictions of phase change material embedded solar air heater
    Verma, Geeta
    Singh, Satyender
    Chander, Subhash
    Dhiman, Prashant
    JOURNAL OF ENERGY STORAGE, 2022, 47
  • [6] Thermal management analysis of new liquid cooling of a battery system based on phase change material and thermoelectric cooler
    Pakrouh, R.
    Ranjbar, A. A.
    Hosseini, M. J.
    Rahimi, M.
    APPLIED THERMAL ENGINEERING, 2023, 231
  • [7] Numerical simulation of hybrid battery thermal management system combining of thermoelectric cooler and phase change material
    Liu, Xun
    Zhang, Chen-Feng
    Zhou, Jian-Gang
    Xiong, Xin
    Zhang, Cheng-Cai
    Wang, Yi-Ping
    ENERGY REPORTS, 2022, 8 : 1094 - 1102
  • [8] Experimental and numerical analysis of the thermal performance of polyurethane foams panels incorporating phase change material
    Amaral, C.
    Silva, T.
    Mohseni, F.
    Amaral, J. S.
    Amaral, V. S.
    Marques, P. A. A. P.
    Barros-Timmons, A.
    Vicente, R.
    ENERGY, 2021, 216
  • [9] Numerical Analysis on the Thermal Performance of Chilled Ceiling Panels Using Encapsulated Phase Change Material
    Wu, Xi-Ping
    Zhang, Jun-ying
    Bruno, Frank
    Belusko, Martine
    2009 IEEE 16TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1 AND 2, PROCEEDINGS, 2009, : 1543 - +
  • [10] Thermal performance analysis of phase change material based thermal storage system using a generalized numerical model with volumetric expansion and shrinkage
    Janghel, Diwakar
    Karagadde, Shyamprasad
    Saha, Sandip K.
    APPLIED THERMAL ENGINEERING, 2020, 180