TDCpix pixel detector ASIC with 100 ps time stamping

被引:1
|
作者
Rinella, G. Aglieri [1 ]
Bonacini, S. [1 ]
Jarron, P. [1 ]
Kaplon, J. [1 ]
Kluge, A. [1 ]
Albarran, E. Martin [1 ]
Morel, M. [1 ]
Noy, M. [1 ]
Perktold, L. [1 ]
Perrin-Terrin, M. [1 ]
Poltorak, K. [1 ]
机构
[1] CERN, Geneva, Switzerland
关键词
Application specific integrated circuits; Detector instrumentation; Electronics; Fast timing; Front-end systems; High energy physics instrumentation; Time resolution; Time to digital converters; Mixed signal circuits; TIMING FRONT-END; GIGATRACKER;
D O I
10.1016/j.nima.2023.168331
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The TDCpix pixel read-out ASIC contains 1800 pixels arranged in 40 columns and 45 rows with the dimension of 300 & mu;m x 300 & mu;m. Each pixel contains a preamplifier and shaper circuit with a dynamic range of 0.8 to 10 fC and a rise time of 5 ns, followed by a Leading-Edge discriminator with Time-over-Threshold correction. The discriminator outputs of each pixel are connected to time-to-digital converters (TDC) measuring the time when the input signal has exceeded the threshold and the pulse width with a binning of 97 ps. The electronics noise of pre-amplifier/shaper is 170 e- or 2.7 mV rms with a gain of 65 mV/fC. The jitter of the entire processing chain for an electrical input signal of 2.4 fC is lower than 60 ps rms. The ASIC has been designed to work in radiated environments of 6 * 104 Gray per year and 2 x 1014 1 MeV neutron equivalent cm-2.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] A 200 TIME-OF-FLIGHT PIXEL IMAGING ASIC, TDCPIX
    Kluge, A.
    Rinella, G. Aglieri
    Fiorini, M.
    Jarron, P.
    Kaplon, J.
    Albarran, M. E. Martin
    Morel, M.
    Noy, M.
    Perktold, L.
    Poltorak, K.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S82 - S82
  • [2] The TDCpix readout ASIC: A 75 Ps resolution timing front-end for the NA62 Gigatracker hybrid pixel detector
    Kluge, A.
    Rinella, G. Aglieri
    Bonacini, S.
    Jarron, P.
    Kaplon, J.
    Morel, M.
    Noy, M.
    Perktold, L.
    Poltorak, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 511 - 514
  • [3] A 9-Channel, 100 ps LSB Time-to-Digital Converter for the NA62 Gigatracker Readout ASIC (TDCpix)
    Perktold, L.
    Rinella, G. Aglieri
    Martin, E.
    Noy, M.
    Kluge, A.
    Kloukinas, K.
    Kaplon, J.
    Jarron, P.
    Morel, M.
    Fiorini, M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] A silicon pixel readout ASIC with 100 ps time resolution for the NA62 experiment
    Dellacasa, G.
    Garbolino, S.
    Marchetto, F.
    Martoiu, S.
    Mazza, G.
    Rivetti, A.
    Wheadon, R.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [5] A Pixel Front-End ASIC in 0.13 μm CMOS for the NA62 Experiment with on Pixel 100 ps Time-to-Digital Converter
    Martoiu, S.
    Rivetti, A.
    Ceccucci, A.
    Ramusino, A. Cotta
    Chiozzi, S.
    Dellacasa, G.
    Fiorini, M.
    Garbolino, S.
    Jarron, P.
    Kaplon, J.
    Kluge, A.
    Marchetto, F.
    Albarran, E. Martin
    Mazza, G.
    Noy, M.
    Riedler, P.
    Tiurianemi, S.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 55 - +
  • [6] The pixel detector readout ASIC for the MicroVertex Detector of the PANDA experiment
    Mazza, G.
    Calvo, D.
    De Remigis, P.
    Kugathasan, T.
    Mignone, M.
    Rivetti, A.
    Toscano, L.
    Wheadon, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 197 - 199
  • [7] The TDCpix ASIC: High Rate Readout of Hybrid Pixels with Timing Resolution Better Than 200 ps
    Rinella, Gianluca Aglieri
    Bonacini, Sandro
    Jarron, Pierre
    Kaplon, Jan
    Kluge, Alexander
    Morel, Michel
    Noy, Matthew
    Perktold, Lukas
    Poltorak, Karolina
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Sparse SiPM Pixel Arrangement for a TOF-PET Detector Design that Achieves 100 ps Coincidence Time Resolution
    Cates, J. W.
    Levin, C. S.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (07) : 665 - 672
  • [9] A pixel detector asic for dosimetry using time-over-threshold energy measurements
    Wong, W. S.
    Anton, G.
    Ballabriga, R.
    Boehnel, M.
    Campbell, M.
    Heijne, E.
    Llopart, X.
    Michel, T.
    Muenster, I.
    Plackett, R.
    Sievers, P.
    Takoukam, P.
    Tlustos, L.
    Valerio, P.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1619 - 1623
  • [10] A prototype hybrid pixel detector ASIC for the CLIC experiment
    Valerio, P.
    Alozy, J.
    Arfaoui, S.
    Ballabriga, R.
    Benoit, M.
    Bonacini, S.
    Campbell, M.
    Dannheim, D.
    De Gaspari, M.
    Felici, D.
    Kulis, S.
    Llopart, X.
    Nascetti, A.
    Poikela, T.
    Wong, W. S.
    JOURNAL OF INSTRUMENTATION, 2014, 9