Distribution networks reliability assessment considering distributed automation system with penetration of DG units and SOP devices

被引:6
|
作者
Shafik, M. B. [1 ,2 ]
Elbarbary, Zakaria M. S. [3 ]
Bu, Siqi [2 ]
Azmy, Ahmed M. [4 ]
Hussien, Mohamed G. [4 ,5 ]
机构
[1] Kafrelsheikh Univ, Fac Engn, Dept Elect Engn, Kafrelsheikh 33516, Egypt
[2] Hong Kong Polytech Univ, Dept Elect & Elect Engn, Hong Kong 999077, Peoples R China
[3] King Khalid Univ, Coll Engn, Dept Elect Engn, Abha, Saudi Arabia
[4] Tanta Univ, Fac Engn, Dept Elect Power & Machines Engn, Tanta 31527, Egypt
[5] Harbin Inst Technol Shenzhen, Sch Mech Engn & Automat, Shenzhen, Peoples R China
关键词
Distribution networks; Reliability; Distributed automation system; Cost; benefit study; DG units; Soft Open Points; ENERGY-RESOURCES;
D O I
10.1016/j.egyr.2023.05.224
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electric utility industry is moving towards a deregulated and competitive market to meet customer expectations. So, system performance and reliability assessments are getting targeted more than before. Several performance measures of reliability are developed in the literature. In this research, the NEPLAN Simulator reliability analysis module is used to determine all the reliability indices in different cases of study considering the effect of the Advanced Distributed Automation System (ADAS). The analysis also benefits from the presence of Penetration of Distributed Generation (DG) units and Soft Open Points (SOP) to enhance system reliability alongside power quality. Therefore, this paper provides a methodology based on a cost/benefit study for distribution networks to define the best location of DG units and SOP devices that leads to better reliability indices. The objectives of the study are demonstrated and investigated through Bus 4 of the standard reliability Roy Bollington Test System (RBTS). NEPLAN uses a tool to apply the Reliability Centered Maintenance (RCM) strategy, which leads to a substantial reduction of maintenance expenses. Simulation results indicate a significant reduction in system reliability cost by 65.8% with significant enhancement in the average of all reliability indices and at each load point too such as Customer Average Interruption Duration Index (CAIDI) which is improved from 40.899 to 29.883, Energy not supplied also is declined by 52.34%. It is also worth saying that, even using DG units or SOP devices separately leads to positive results but the best outcomes are obtained with an appropriate combination of both. & COPY; 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:6199 / 6210
页数:12
相关论文
共 50 条
  • [1] Planning and reliability assessment to integrate distributed automation system into distribution networks utilizing binary hybridPSOandGSAalgorithms considering uncertainties
    Shafik, Muhammed B.
    Chen, Hongkun
    Rashed, Ghamgeen, I
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (11)
  • [2] A novel reliability assessment method for distribution networks based on linear programming considering distribution automation and distributed generation
    Li, Junhui
    Kong, Huichao
    Wang, Wenzhong
    Sun, Liming
    Xiao, Wencong
    Wang, Ziyao
    [J]. IET Renewable Power Generation, 2024, 18 (03) : 529 - 544
  • [3] Distribution system reliability evaluation considering DG impacts
    Wang, S. X.
    Zhao, Wei
    Chen, Y. Y.
    [J]. 2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2603 - 2607
  • [4] Reliability assessment of cyber physical distribution system based on distributed feeder automation
    Zeng, Guangxuan
    Yu, Tao
    Lin, Dan
    Wang, Ziyao
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (12): : 57 - 65
  • [5] Reliability Evaluation of Distribution Network With DG Considering the Reliability of Protective Devices Affected by SFCL
    Kim, Sung-Yul
    Kim, Jin-O
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (05) : 3561 - 3569
  • [6] Intentional islanding for reliability improvement in distribution networks with high DG penetration
    Seca, Luis
    Lopes, J. A. Pecas
    [J]. 2005 International Conference on Future Power Systems (FPS), 2005, : 17 - 21
  • [7] A Novel Integration Technique for Optimal Location & Sizing of DG Units With Reconfiguration in Radial Distribution Networks Considering Reliability
    Raza, Ali
    Zahid, Muhammad
    Chen, Jinfu
    Qaisar, Saeed Mian
    Ilahi, Tehseen
    Waqar, Asad
    Alzahrani, Ahmad
    [J]. IEEE ACCESS, 2023, 11 : 123610 - 123624
  • [8] Reliability Analysis of Distribution System with DG Considering Operation Homogeneity
    Qi, Yanpeng
    Wang, Feng
    Wang, Diandian
    [J]. 2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [9] Distribution System Reconfiguration Considering Customer and DG Reliability Cost
    Cho, Sung-Min
    Shin, Hee-Sang
    Park, Jin-Hyun
    Kim, Jae-Chul
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (04) : 486 - 492
  • [10] Reliability Assessment of Distribution System Considering Customer-Owned Distributed Generation
    Hashemi, S. M.
    Sadoughi, A.
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (02): : 1000 - 1006