Laboratory validation of an integrative passive sampler for per- and polyfluoroalkyl substances in water

被引:0
|
作者
Edmiston, Paul L. [1 ]
Hill, Noah [1 ]
Hershberger, Riley [1 ]
Hartmann, Heather [1 ]
Carter, Erika [2 ]
Divine, Craig [2 ]
机构
[1] Coll Wooster, Dept Chem, 943 Coll Mall, Wooster, OH 44691 USA
[2] Arcadis Inc, Chicago, IL USA
基金
美国国家科学基金会;
关键词
PERFLUOROOCTANE SULFONATE; PERFLUOROALKYL SUBSTANCES; COMPETITIVE ADSORPTION; CALIBRATION; ABSORPTION; SORPTION;
D O I
10.1039/d3ew00047h
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A passive sampler for per- and polyfluoroalkyl substances (PFAS) in water has been developed which uses a porous organosilica adsorbent. Some performance characteristics, which remained incompletely answered after prior lab- and field-based testing, were assessed. The integrated response mode of the sampler was verified in bench-scale experiments where the aqueous phase concentration was varied 50-fold in the flow across passive samplers. It was found that the passive samplers were able to accumulate analytes and provide an accurate time-averaged concentration in situations where the PFAS concentration changed significantly over time. The integrated response is facilitated by an average 40-fold slower back diffusion rate compared to PFAS adsorption rates, attributed to in-particle diffusion. The maximum deployment time was assessed using a multi-month laboratory-based sampling event. It was found that the integrated response was maintained over 90 days except for perfluorobutanoic acid (PFBA) and perfluorodecanoic acid (PFDA) where adsorption reached equilibrium after 45 and 60 days of total sampling time, respectively. The mechanism of PFAS adsorption was explored using a column breakthrough curve in combination with previously reported adsorption isotherm data. The use of isotopic dilution for PFAS measurement was studied by measuring the adsorption, recovery, and stability of mass labeled surrogates in laboratory analysis. Surrogates were quantitatively bound and determined to be stable for at least 4 weeks in the adsorbed state. Sampling rates for EPA Method 1633 compounds N-methyl perfluorooctanesulfonamidoacetic acid and N-methyl perfluorooctanesulfonamide were also measured, expanding the existing sampling rate database to a total of 21 PFAS species.
引用
下载
收藏
页码:1849 / 1861
页数:13
相关论文
共 50 条
  • [1] Personal Wearable Sampler for Per- and Polyfluoroalkyl Substances Exposure Assessment
    Niu, Shan
    Zhu, Xinran
    Chen, Ruiwen
    Winchell, Aaron
    Gao, Peng
    Barchowsky, Aaron
    Buchanich, Jeanine M.
    Ng, Carla
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2024, 11 (04) : 301 - 307
  • [2] Passive sampler designed for per- and polyfluoroalkyl substances using polymer-modified organosilica adsorbent
    Hartmann, Heather
    Hefner, Claire
    Carter, Erika
    Liles, David
    Divine, Craig
    Edmiston, Paul L.
    AWWA WATER SCIENCE, 2021, 3 (04):
  • [3] A field-validated equilibrium passive sampler for the monitoring of per- and polyfluoroalkyl substances (PFAS) in sediment pore water and surface water
    Medon, Blessing
    Pautler, Brent G.
    Sweett, Alexander
    Risacher, Florent
    Roberts, Jeff F.
    D'Agostino, Lisa A.
    Conder, Jason
    Gauthier, Jeremy R.
    Mabury, Scott A.
    Patterson, Andrew
    McIsaac, Patricia
    Mitzel, Robert
    Hakimabadi, Seyfollah Gilak
    Pham, Anh Le-Tuan
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2023, 25 (05) : 980 - 995
  • [4] Sampling of freely dissolved per- and polyfluoroalkyl substances (PFAS) in surface water and groundwater using a newly developed passive sampler
    Kaltenberg, Eliza M.
    Dasu, Kavitha
    Lefkovitz, Lisa F.
    Thorn, Jonathan
    Schumitz, Denise
    ENVIRONMENTAL POLLUTION, 2023, 318
  • [5] Occurrence of per- and polyfluoroalkyl substances in water: a review
    Wang, Yifei
    Kim, Juhee
    Huang, Ching-Hua
    Hawkins, Gary L.
    Li, Ke
    Chen, Yongsheng
    Huang, Qingguo
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2022, 8 (06) : 1136 - 1151
  • [6] A critical review on passive sampling in air and water for per- and polyfluoroalkyl substances (PFASs)
    Lai, Foon Yin
    Rauert, Cassandra
    Gobelius, Laura
    Ahrens, Lutz
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 121
  • [7] Application of a Microporous Polyethylene Tube Passive Sampler for Monitoring Per- and Polyfluoroalkyl Substances in Wastewater Influent and Effluent
    Mackie, Rachel
    Hawker, Darryl W.
    Ghorbani Gorji, Sara
    Booij, Kees
    Qu, Xuan
    Bowles, Karl
    Shea, Stefanie
    Higgins, Christopher P.
    Kaserzon, Sarit
    ACS ES&T WATER, 2024, 4 (05): : 2281 - 2291
  • [8] Calibration and validation of a novel passive sampling device for the time integrative monitoring of per- and polyfluoroalkyl substances (PFASs) and precursors in contaminated groundwater
    Kaserzon, Sarit L.
    Vijayasarathy, Soumini
    Braunig, Jennifer
    Mueller, Linus
    Hawker, Darryl W.
    Thomas, Kevin V.
    Mueller, Jochen F.
    JOURNAL OF HAZARDOUS MATERIALS, 2019, 366 : 423 - 431
  • [9] Characterization of Two Passive Air Samplers for Per- and Polyfluoroalkyl Substances
    Ahrens, Lutz
    Harner, Tom
    Shoeib, Mahiba
    Koblizkova, Martina
    Reiner, Eric J.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (24) : 14024 - 14033
  • [10] A critical assessment of passive air samplers for per- and polyfluoroalkyl substances
    Karaskova, Pavlina
    Codling, Garry
    Melymuk, Lisa
    Klanova, Jana
    ATMOSPHERIC ENVIRONMENT, 2018, 185 : 186 - 195