Continuous real-time monitoring of carbon dioxide emitted from human skin by quartz-enhanced photoacoustic spectroscopy

被引:14
|
作者
Zhang, Yixin [1 ]
Xie, Yi [1 ,2 ]
Lu, Juncheng [1 ]
Zhao, Jiasheng [1 ]
Wu, Yuhua [1 ]
Tong, Jinlin [1 ,2 ]
Shao, Jie [1 ]
机构
[1] Zhejiang Normal Univ, Key Lab Opt Informat Detect & Display Technol Zhej, Jinhua 321004, Peoples R China
[2] Wenzhou Univ, Coll Mech & Elect Engn, Wenzhou 325035, Peoples R China
来源
PHOTOACOUSTICS | 2023年 / 30卷
关键词
Human skin gas; CO2; detection; Gas sensor; Quartz-enhanced photoacoustic spectroscopy; SOLID-PHASE MICROEXTRACTION; BREATH; ACETONE; CO2;
D O I
10.1016/j.pacs.2023.100488
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, a skin gas detection system based on quartz enhanced photoacoustic spectroscopy (QEPAS) with a constant temperature collection chamber , an automatic frequency adjustment function was used to collect and monitor carbon dioxide (CO2) emissions from human skin. The detection element of the system is an on -beam structure assembled by a 30.72 kHz quartz tuning fork (QTF). A laser with a wavelength of 4991.26 cm-1 is emitted (with a wavelength adjustment range of 10 cm-1) to excite the QTF. When the integration time is 365 s, the system can achieve a minimum detection limit (MDL) of 2.6 ppmv. The sensitivity of the system is 636.9 ppmv/V. The gas detection system is used to monitor the concentration of CO2 emissions from different parts of the skin and the same part covered by different cosmetics. The CO2 emission rate is defined as the ratio of the skin gas monitoring time of 25 min to the CO2 concentration variable in the gas chamber (volume of 8 mL). The results were collected from three healthy volunteers. Among the six different parts, the cheeks emitted the fastest rate (the average rate was 365.5 ppmv/min) of CO2, the thighs emitted the slowest rate (the average rate was 56.4 ppmv/min) of CO2. Comparing the experimental results of the six sites at different times, the order of the CO2 emission rate is identical for all six sites. In the experiments with the three cosmetic products (experimental site: forearm), comparing the CO2 emission rate from clean skin with the CO2 emission rate from cosmetic-covered skin shows that sunscreen is the most breathable, followed by barrier cream, and foundation is the least breathable.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Real-Time Detection of Metabolic Carbon Dioxide Volume Fraction in Skin Based on Frequency-Locked Quartz-Enhanced Photoacoustic Spectroscopy
    Zhang, Yixin
    Wu, Huakun
    Wu, Qiong
    Liu, Wen
    Shao, Jie
    ACTA OPTICA SINICA, 2025, 45 (04)
  • [2] Development of continuous monitoring of ambient carbon dioxide using near-infrared quartz-enhanced photoacoustic spectroscopy
    Lee, Mingu
    Sugahara, Syo
    Omi, Daijiro
    Fujita, Michiya
    Tonokura, Kenichi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (01)
  • [3] Detection of Trace Sulfur Dioxide Gas Using Quartz-Enhanced Photoacoustic Spectroscopy
    Zhang Leilei
    Liu Jiaxiang
    Zhu Zhizhen
    Fang Yonghua
    Wu Yue
    Yang Wenkang
    Tao Mengqi
    Ning Zhiqiang
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (21)
  • [4] Compact and portable quartz-enhanced photoacoustic spectroscopy sensor for carbon monoxide environmental monitoring in urban areas
    Sgobba, Fabrizio
    Sampaolo, Angelo
    Patimisco, Pietro
    Giglio, Marilena
    Menduni, Giansergio
    Ranieri, Ada Cristina
    Hoelzl, Christine
    Rossmadl, Hubert
    Brehm, Christian
    Mackowiak, Verena
    Assante, Dario
    Ranieri, Ezio
    Spagnolo, Vincenzo
    PHOTOACOUSTICS, 2022, 25
  • [5] Carbon dioxide and ammonia detection using 2 μm diode laser based quartz-enhanced photoacoustic spectroscopy
    R. Lewicki
    G. Wysocki
    A.A. Kosterev
    F.K. Tittel
    Applied Physics B, 2007, 87 : 157 - 162
  • [6] Carbon dioxide and ammonia detection using 2 μm diode laser based quartz-enhanced photoacoustic spectroscopy
    Lewicki, R.
    Wysocki, G.
    Kosterev, A. A.
    Tittel, F. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 87 (01): : 157 - 162
  • [7] Continuous trace gas concentration measurement based on quartz-enhanced photoacoustic spectroscopy technique
    Tong, Y.
    Ma, Y. F.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2019, 13 (1-2): : 51 - 55
  • [8] Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring
    Hongpeng Wu
    Lei Dong
    Huadan Zheng
    Yajun Yu
    Weiguang Ma
    Lei Zhang
    Wangbao Yin
    Liantuan Xiao
    Suotang Jia
    Frank K. Tittel
    Nature Communications, 8
  • [9] Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring
    Wu, Hongpeng
    Dong, Lei
    Zheng, Huadan
    Yu, Yajun
    Ma, Weiguang
    Zhang, Lei
    Yin, Wangbao
    Xiao, Liantuan
    Jia, Suotang
    Tittel, Frank K.
    NATURE COMMUNICATIONS, 2017, 8
  • [10] Sulfur Dioxide Detection Using CW-DFB-QCL Based Quartz-Enhanced Photoacoustic Spectroscopy
    Waclawek, J. P.
    Lewicki, R.
    Moser, H.
    Brandstetter, M.
    Tittel, F. K.
    Lendl, B.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,