Pilot study on 11C-CFT dynamic imaging using total-body PET/CT: biodistribution and radiation dosimetry in Parkinson's disease

被引:5
|
作者
Xin, Mei [1 ]
Li, Lianghua [1 ]
Wang, Cheng [1 ]
Shao, Hongda [1 ]
Liu, Jianjun [1 ]
Zhang, Chenpeng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, Shanghai, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2023年 / 14卷
基金
中国国家自然科学基金;
关键词
C-11-CFT; dopamine transporter; total-body PET; CT; time-activity curve; effective dose; DOPAMINE TRANSPORTER RADIOLIGAND; TOMOGRAPHY;
D O I
10.3389/fneur.2023.1153779
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveTotal-body PET/CT equipment, uEXPLORER, is a newly developed imaging technology with a superior resolution, high sensitivity, and high signal-to-noise ratio, providing unique application advantages in the pharmacokinetic evaluation of positron tracers. While C-11-CFT PET/CT has been widely utilized in the early diagnosis of Parkinson's disease (PD), it is limited by the short half-life of the radionuclide and an incomplete understanding of its biological distribution in humans. This study aimed to use a total-body PET/CT dynamic scan with C-11-CFT imaging to describe the real-time internal biodistribution in PD patients and to obtain accurate radiation dosimetry. MethodsSix male subjects with suspected PD underwent dynamic C-11-CFT total-body PET/CT. Following a bedside intravenous bolus injection of 373.3 +/- 71.56 MBq of C-11-CFT, PET acquisition was performed synchronously for 75 min with a maximum axial field of view (AFOV) of 194 cm. Time-activity curves (TACs) were generated by delineating volumes of interest (VOIs) of the sourced organs using PMOD software. Tracer kinetics and cumulative organ activities were calculated, and absorbed doses were calculated and estimated using the OLINDA/EXM software. ResultsIn the systemic TAC analysis of C-11-CFT, several unique types of distribution patterns were obtained among several major organs, including a "Fast-in Fast-out" pattern in the kidneys, lungs, spleen, and thyroid, a "Fast-in Slow-out" curve in the heart wall, a "Slow-in Slow-out" mode in the liver, a "Low-level extending" pattern in the whole brain and muscle, and a "Slow-in to plateau" trend in the striatum and bone. The effective dose of C-11-CFT was calculated to be 2.83E-03 mSv/MBq, which is only one-third of the literature value measured by the conventional method. Moreover, this dose is much lower compared to all other doses of DAT radioligands used in PET imaging. ConclusionThis study is a pioneering application of total-body PET/CT to C-11-CFT dynamic imaging. Our results confirmed that C-11-CFT has a favorable total body biodistribution, an extremely low internal radiation dose, and high imaging quality, making it suitable for reasonable PD diagnosis in patients requiring multiple follow-up examinations.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] 11C-CFT PET brain imaging in Parkinson's disease using a total-body PET/CT scanner
    Sun, Xiaolin
    Tan, Xiaoyue
    Zhang, Qing
    He, Shanzhen
    Wang, Siyun
    Zhou, Yongrong
    Huang, Qi
    Jiang, Lei
    EJNMMI PHYSICS, 2024, 11 (01)
  • [2] 11C-CFT PET brain imaging in Parkinson's Disease using a total-body PET/CT scanner
    Sun, X.
    Tan, X.
    Zhang, Q.
    Jiang, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S729 - S729
  • [3] Exploring the nigrostriatal and digestive interplays in Parkinson's disease using dynamic total-body [11C]CFT PET/CT
    Xin, Mei
    Wang, Yihan
    Yang, Xinlan
    Li, Lianghua
    Wang, Cheng
    Gu, Yue
    Zhang, Chenpeng
    Huang, Gang
    Zhou, Yun
    Liu, Jianjun
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (08) : 2271 - 2282
  • [4] The initial experience of 11C-CFT PET/CT combined with NeuroQ software in the evaluation of Parkinson's Disease
    Sun, Xun
    Liu, Fang
    Lan, Xiaoli
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [5] Kinetic modeling with different reference tissues improves 11C-CFT total-body PET/CT quantification studies in parkinsonism
    Xin, Mei
    Wang, Yihan
    Zhang, Chenpeng
    Zhou, Yun
    Liu, Jianjun
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [6] Human Radiation Dose Estimation of 11C-CFT Using Whole-Body PET
    Huang, Tingting
    Wang, Hongliang
    Tang, Ganghua
    Liang, Xiang
    Deng, Huaifu
    Yi, Chang
    Zhang, Xiangsong
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (12) : 1159 - 1162
  • [7] Quantitative Research of 11C-CFT and 18F-FDG PET in Parkinson's Disease: A Pilot Study With NeuroQ Software
    Sun, Xun
    Liu, Fang
    Li, Qingyao
    Gai, Yongkang
    Ruan, Weiwei
    Wimalarathne, Dilani Neranjana
    Hu, Fan
    Tan, Xubo
    Lan, Xiaoli
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [8] Characteristics and influencing factors of 11C-CFT PET imaging in patients with early and late onset Parkinson's disease
    Fan, Kangli
    Zhao, Hongguang
    Li, Yinghua
    Du, Xiaoxiao
    Dai, Yuyin
    Gao, Lulu
    Li, Yi
    Sun, Zhihui
    Zhang, Ying
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [9] Improved accuracy of the biodistribution and internal radiation dosimetry of 13N-ammonia using a total-body PET/CT scanner
    Yu, Xiaofeng
    Sun, Hongyan
    Xu, Lian
    Han, Yuan
    Wang, Cheng
    Li, Lianghua
    Ng, YeeLing
    Shi, Fuxiao
    Qiu, Ju
    Huang, Gang
    Zhou, Yun
    Chen, Yumei
    Liu, Jianjun
    MEDICAL PHYSICS, 2023, 50 (09) : 5865 - 5874
  • [10] Tremor and non-tremor Parkinson's disease show different patterns of 11C-CFT and 18F-FDG PET/CT imaging
    Xin, M.
    Wang, C.
    Liu, J.
    Huang, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S409 - S409