Voltammetric determination of a fluoroquinolone antibiotic based on multilayer reduced graphene oxide sensor prepared directly, promptly by electrochemically expanding graphite electrode surface

被引:4
|
作者
Ba Vuong Do [1 ,2 ]
Hoang Anh Nguyen [1 ]
Thi Lieu Nguyen [3 ]
Thi Thu Ha Vu [1 ]
Quoc Hung Le [1 ]
Hong Phong Pham [1 ]
Thi Thao Ta [2 ]
Thi Hai Yen Pham [1 ]
机构
[1] Vietnam Acad Sci & Technol, Inst Chem, Hanoi, Vietnam
[2] Vietnam Nat Univ, Univ Sci, Fac Chem, Hanoi, Vietnam
[3] Quy Nhan Univ, Fac Nat Sci, Quy Nhon, Vietnam
关键词
Ciprofloxacin; fluoroquinolone antibiotic; electrochemical sensor; multilayer reduced graphene oxide; graphite expansion; MESOPOROUS CARBON; PASTE ELECTRODE; COMPOSITE FILM; CIPROFLOXACIN; NANOPARTICLES; ACID;
D O I
10.1080/03067319.2021.1982924
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ciprofloxacin (Cip), a fluoroquinolone antibiotic, was determined by linear sweep adsorptive stripping voltammetric method using multilayer reduced graphene oxide electrode (m-rGO). The m-rGO electrode was fabricated directly, simply and promptly from graphite platform by potentiostatic technique without further modification. The produced electrode exhibited excellent performance for ciprofloxacin (Cip) determination with a much higher signal of Cip than that on the initial graphite electrode (13.4 times). This dominance of the m-rGO electrode resulted from the large electrochemically active surface area, electrochemical catalysis, suitable functional groups on the electrode surface. Experimental conditions such as the electrode fabrication time, the supporting solution, and accumulation time were optimised to obtain the Cip highest signal. A Cip analytical method established under the optimal conditions had a good linear relationship between the Cip signal with its concentration range from 0.5 to 20 mu M (R-2 = 0.9953). The method showed a low detection limit (LOD = 0.078 mu M), satisfactory reproducibility (RSD = 1.50%), and high accuracy. Cip concentration in a spiked lake water sample determined by the proposed method with acceptable precision (RSD = 5.59%) and trueness (recovery = 94.2-106.3%) was comparable with LC-MS/MS method.
引用
收藏
页码:8141 / 8157
页数:17
相关论文
共 50 条
  • [1] A voltammetric sensor based on electrochemically reduced graphene modified electrode for sensitive determination of midecamycin
    Xi, Xia
    Ming, Liang
    ANALYTICAL METHODS, 2012, 4 (09) : 3013 - 3018
  • [2] Fabrication of reduced graphene oxide/ruthenium oxide modified graphite electrode for voltammetric determination of tryptophan
    Mahesh Bhaskar Hegde
    Kikkeri Narasimha Shetty Mohana
    Ambale Murthy Madhusudhana
    M. M. Vinay
    Y. Arthoba Nayaka
    Ningappa Kumara Swamy
    Graphene and 2D Materials Technologies, 2021, 6 (3-4): : 25 - 34
  • [3] Simple and Sensitive Voltammetric Determination of Esculetin Using Electrochemically Reduced Graphene Oxide Modified Electrode
    Li, Yinfeng
    Li, Ying
    Li, Kunjing
    Ye, Baoxian
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2015, 62 (07) : 652 - 660
  • [4] Hydrophilic graphene surface prepared by electrochemically reduced micellar graphene oxide as a platform for electrochemical sensor
    Akkarachanchainon, Nontapol
    Rattanawaleedirojn, Pranee
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    TALANTA, 2017, 165 : 692 - 701
  • [5] Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Jing
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (04) : 749 - 756
  • [6] polycalconcarboxylic acid/electrochemically reduced graphene oxide-modified glassy carbon electrode-based voltammetric sensor for the simultaneous determination of dopamine and tyrosine
    Swathy, S.
    Kodakat, Keerthi
    Kumar, K. Girish
    IONICS, 2024, 30 (06) : 3521 - 3539
  • [7] A one-step electrochemically reduced graphene oxide based sensor for sensitive voltammetric determination of furfural in milk products
    Wang, Qiuqiu
    Zhang, Juanhua
    Xu, Yanbo
    Wang, Yingyi
    Wu, Liang
    Weng, Xuexiang
    You, Chunping
    Feng, Jiuju
    ANALYTICAL METHODS, 2021, 13 (01) : 56 - 63
  • [8] Voltammetric sensor for COVID-19 drug Molnupiravir on modified glassy carbon electrode with electrochemically reduced graphene oxide
    Kablan, Sevilay Erdogan
    Recber, Tuba
    Tezel, Gizem
    Timur, Selin Seda
    Karabulut, Cansu
    Karabulut, Tutku Ceren
    Eroglu, Hakan
    Kir, Sedef
    Nemutlu, Emirhan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 920
  • [9] A sensitive electrochemical sensor based on polypyrrole/electrochemically reduced graphene oxide for the determination of imidacloprid
    Chen, Chenglong
    Han, Zhen
    Lei, Wu
    Ding, Yong
    Lv, Jingjing
    Xia, Mingzhu
    Wang, Fengyun
    Hao, Qingli
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2019, 9 (03): : 143 - 152
  • [10] Simultaneous Voltammetric Determination of Ascorbic Acid, Paracetamol, and Caffeine Using Electrochemically Reduced Graphene-Oxide-Modified Electrode
    Nguyen Hai Phong
    Tran Thanh Tam Toan
    Mai Xuan Tinh
    Tran Ngoc Tuyen
    Tran Xuan Mau
    Dinh Quang Khieu
    JOURNAL OF NANOMATERIALS, 2018, 2018