δARD loss for low-contrast medical image segmentation

被引:0
|
作者
Zhao, Yu [1 ]
Shen, Xiaoyan [2 ]
Chen, Jiadong [1 ]
Qian, Wei [1 ]
Ma, He [3 ,4 ]
Sang, Liang [5 ]
机构
[1] Northeastern Univ, Coll Med & Biol Informat Engn, Shenyang 110169, Liaoning, Peoples R China
[2] Dongguan Univ Technol, Sch Life Hlth & Technol, Dongguan 523808, Guangdong, Peoples R China
[3] Northeastern Univ, Coll Med & Biol Informat Engn, Minist Educ, Shenyang 110169, Liaoning, Peoples R China
[4] Northeastern Univ, Key Lab Intelligent Comp Med Image, Minist Educ, Shenyang 110169, Liaoning, Peoples R China
[5] First Hosp China Med Univ, Dept Ultrasound, Shenyang 110002, Liaoning, Peoples R China
来源
关键词
image segmentation; loss function; low-contrast medical images;
D O I
10.1088/2632-2153/ad1d06
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Medical image segmentation is essential to image-based disease analysis and has proven to be significantly helpful for doctors to make decisions. Due to the low-contrast of some medical images, the accurate segmentation of medical images has always been a challenging problem. The experiment found that UNet with current loss functions cannot capture subtle information in target contours or regions in low-contrast medical images, which are crucial for subsequent disease diagnosis. We propose a robust loss by incorporating the difference in average radial derivative (ARD), length and region area to further help the network to achieve more accurate segmentation results. We evaluated the proposed loss function using UNet as the base segmentation network compared to five conventional loss functions on one private and four public medical image datasets. Experimental results illustrate that UNet with the proposed loss function can achieve the best segmentation performance, even better than the outstanding deep learning models with original loss functions. Furthermore, three representative datasets were chosen to validate the effectiveness of the proposed delta ARD loss function with seven different models. The experiments revealed delta ARD loss's plug-and-play feature and its robustness over multiple models and datasets.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Low-Contrast Medical Image Segmentation via Transformer and Boundary Perception
    Zhang, Yinglin
    Xi, Ruiling
    Wang, Wei
    Li, Heng
    Hu, Lingxi
    Lin, Huiyan
    Towey, Dave
    Bai, Ruibin
    Fu, Huazhu
    Higashita, Risa
    Liu, Jiang
    IEEE TRANSACTIONS ON EMERGING TOPICS IN COMPUTATIONAL INTELLIGENCE, 2024, 8 (03): : 2297 - 2309
  • [2] Active contour based segmentation of low-contrast medical images
    Piotrowski, Marek
    Szczepaniak, Piotr S.
    IEE Conference Publication, 2000, (476): : 104 - 109
  • [3] Active contour based segmentation of low-contrast medical images
    Piotrowski, M
    Szczepaniak, PS
    FIRST INTERNATIONAL CONFERENCE ON ADVANCES IN MEDICAL SIGNAL AND INFORMATION PROCESSING, 2000, (476): : 104 - 109
  • [4] Study of Low-Contrast Digital Meter Image Segmentation Algorithm
    Chen Xiaojun
    Hu Tao
    Wang Dandan
    PROCEEDINGS OF 2013 IEEE 11TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2013, : 713 - 716
  • [5] A New Method for Segmentation of Noisy, Low-Contrast Image Sequences
    Chuang, Hsiao-Chiang
    Comer, Mary L.
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 2868 - 2871
  • [6] High-Resolution Encoder-Decoder Networks for Low-Contrast Medical Image Segmentation
    Zhou, Sihang
    Nie, Dong
    Adeli, Ehsan
    Yin, Jianping
    Lian, Jun
    Shen, Dinggang
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2020, 29 (29) : 461 - 475
  • [7] KACM: A KIS-awared active contour model for low-contrast image segmentation
    Xu, Yaya
    Dang, Hongyu
    Tang, Liming
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 255
  • [8] Automating shockwave segmentation in low-contrast coherent shadowgraphy
    Jaka Pribošek
    Peter Gregorčič
    Janez Diaci
    Machine Vision and Applications, 2015, 26 : 485 - 494
  • [9] Paediatric Liver Segmentation for Low-Contrast CT Images
    Bajger, Mariusz
    Lee, Gobert
    Caon, Martin
    DATA DRIVEN TREATMENT RESPONSE ASSESSMENT AND PRETERM, PERINATAL, AND PAEDIATRIC IMAGE ANALYSIS, 2018, 11076 : 169 - 178
  • [10] Automating shockwave segmentation in low-contrast coherent shadowgraphy
    Pribosek, Jaka
    Gregorcic, Peter
    Diaci, Janez
    MACHINE VISION AND APPLICATIONS, 2015, 26 (04) : 485 - 494