Investigation of the fire hazard of underground space fire scenarios in urban metro tunnels under natural ventilation: Analysis of the impact of tunnel slope on smoke back-layering length

被引:0
|
作者
Su, Zhihe [1 ]
Li, Yanfeng [1 ]
Zhong, Hua [2 ]
Li, Junmei [1 ]
Yang, Shi [1 ]
Du, Tianmei [1 ]
Huang, Youbo [3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, 100 Pingleyuan, Beijing 100124, Peoples R China
[2] Nottingham Trent Univ, Sch Architecture Design & Built Environm, 203 Arkwright Bldg, Nottingham NG1 4FQ, England
[3] Chongqing Univ Sci & Technol, Coll Safety Engn, Chongqing, Peoples R China
关键词
Inclined metro tunnel; tunnel fire; smoke back-layering length; fire source location; transition slope; natural ventilation;
D O I
10.1177/01436244231223045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The smoke back-layering length is a crucial parameter for evacuating people in both road and subway tunnel fires. This study investigates the fire hazard induced by carriage fire in inclined metro tunnels under natural ventilation. The parameter 'transition slope' is defined to measure the smoke flow from the carriage head in the upstream direction to the tunnel or not due to the stack effect of the tunnel slope. The aim of this paper is to analyse the effects of changes in cross-section, downstream length, tunnel slope, and carriage side-door coupling on smoke behaviour characteristics by experiment and simulation methods. A piecewise function expression between dimensionless smoke back-layering length, downstream length, and tunnel slope for carriage fires in an inclined tunnel under natural ventilation is proposed by theoretical analysis. At the same time, a 1:15 scale model experiment was conducted to initially analyse the characteristics of smoke movement. Following this, full-scale numerical simulations were employed to complement the model experiment and quantify the principles governing smoke movement. The experimental results show that the tunnel slope has a significant effect on the smoke back-layering length. In contrast, the influence of the heat release rate was found to be relatively minor. In addition, simulation results show that the tunnel slope has no significant effect on the smoke back-layering length when the fire location is approximately 20 m from the train head, and the tunnel slope is in the range of 2.29 degrees similar to 3.43 degrees (4% similar to 6%). For small tunnel slopes, smoke spreads in the tunnel, and the smoke back-layering length produced by the virtual fire source shows a different law from the previous study model. Finally, the correlation coefficient of the piecewise function in theoretical analysis is fitted by combining the experimental and numerical simulation results.Practical applicationThis study provides valuable insights into the practical implications of controlling and mitigating the impact of fires in inclined metro tunnels. By understanding the critical role of tunnel slope and providing a quantitative tool for smoke spread law assessment, this study contributes to the enhancement of safety measures and the protection of lives in tunnel environments during fire incidents.
引用
收藏
页码:161 / 184
页数:24
相关论文
共 27 条
  • [1] Study of smoke back-layering length with different longitudinal fire locations in inclined tunnels under natural ventilation
    Kong, Jie
    Xu, Zhisheng
    You, Wenjiao
    Wang, Beilei
    Liang, Yin
    Chen, Tao
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 107
  • [2] Experimental investigation of the thermal back-layering length in a branched tunnel fire under longitudinal ventilation
    Huang, Youbo
    Li, Yanfeng
    Li, Jiaxin
    Wu, Ke
    Li, Haihang
    Zhu, Kai
    Li, Junmei
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 173
  • [3] Study of slope effect on smoke back-layering length and ceiling temperature in tunnel fires under natural ventilation
    Wang, Peng
    She, Chaowen
    Chen, Junmin
    Xu, Zhijie
    Chen, Yanqiu
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 185
  • [4] Investigation on smoke propagation behavior and smoke back-layering length of fires in an inclined tunnel under natural ventilation
    Wang B.
    Peng W.
    Zhong W.
    Liang T.
    Tunnelling and Underground Space Technology, 2024, 150
  • [5] Study on the smoke back-layering length in a tilted tunnel with vertical shaft under natural ventilation
    Yi, Liang
    Lan, Shihan
    Wang, Xiaofei
    Bu, Rongwei
    Zhou, Yang
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [6] Experimental investigation on the smoke back-layering length in a branched tunnel fire considering different longitudinal ventilations and fire locations
    Yang, Xiaolong
    Luo, Yueyang
    Li, Zhisheng
    Guo, Hanwen
    Zhang, Yuchun
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [7] Study on the smoke back-layering and critical ventilation in the road tunnel fire at high altitude
    Zhang, Shaogang
    Wang, Jinhui
    He, Kun
    Yao, Yongzheng
    Peng, Min
    FIRE AND MATERIALS, 2019, 43 (04) : 422 - 429
  • [8] Study on the smoke back-layering length in a tilted tunnel with vertical shaft under natural ventilation
    Yi, Liang
    Lan, Shihan
    Wang, Xiaofei
    Bu, Rongwei
    Zhou, Yang
    Case Studies in Thermal Engineering, 2022, 39
  • [9] A numerical study on smoke back-layering length in V-shaped tunnels under natural ventilation
    Xie, En
    Zhao, Wangda
    Xu, Zhisheng
    Zhang, Xiaochun
    Xu, Weiku
    Wang, Tianxiong
    He, Lu
    FIRE AND MATERIALS, 2022, 46 (08) : 1208 - 1221
  • [10] Study on the double effect of the tunnel slope on the fire induced smoke back-layering distance in naturally ventilated inclined tunnels
    Sun, Jiayun
    Wang, Junheng
    Fang, Zheng
    Tang, Zhi
    Merci, Bart