Analysis of AC Losses in KSTAR Superconducting PF Magnets at Low Current Ramp Rates

被引:1
|
作者
Kim, Mu-yong [1 ]
Lee, Hyunjung [1 ]
Kwon, Giil [1 ]
Nam, Seokho [1 ]
Kim, Hyun Wook [1 ]
Yonekawa, Hirofumi [1 ]
Kim, Kwang Pyo [1 ]
Park, Kaprai [1 ]
机构
[1] Korea Inst Fus Energy, Dajeon 34133, South Korea
关键词
Superconducting magnets; Loss measurement; Magnetic hysteresis; Current measurement; Temperature measurement; Magnetic confinement; Frequency measurement; AC loss; KSTAR; poloidal field coil; superconducting magnet;
D O I
10.1109/TASC.2024.3354215
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To achieve nuclear fusion energy generation, continuous confinement of high-current and long-pulse plasma is necessary. KSTAR has been conducting experiments to achieve this goal. In order to maintain a steady state of plasma current, the superconducting magnets of the tokamak should also be operated stably, with heat controlled to a minimum. However, a slight increase in the outlet temperature of the KSTAR PF (poloidal field) magnet and current ripple were observed, particularly when the current ramp rate is 0.5 kA/s or less. In this range, the evaluated AC loss showed a different trend compared to the range where the current ramp rate was higher than 0.5 kA/s. The total heat load was observed to be significantly higher than the theoretical value, which means that losses must be added. This could be a hindering factor in the operation of long pulse plasmas. To ensure stable plasma control, the current operation of the superconducting magnet coils should be optimized and the AC losses should be applied accurately in the full range of ramp rate. In this article, the parametric study of AC losses based on the results of the PF coil in the low current ramp rate were analyzed to stably operate the superconducting magnet.
引用
下载
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] Analysis of the Reversal Flow Phenomenon of Supercritical Helium Due to AC Losses in the KSTAR PF Magnets at the Low Current
    Lee, H. J.
    Park, Y. M.
    Chu, Y.
    Oh, D. K.
    Song, N. H.
    Park, H. T.
    Yang, H. L.
    Kwon, M.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 2012 - 2015
  • [2] AC Losses Analysis of HTS Composite Conductors With Different Current Ramp Rates
    Wu, Yue
    Chen, Zheng
    Geng, Guoli
    Fang, Jin
    Liu, Yanchao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
  • [3] Analysis of the Helium Behavior Due to AC Losses in the KSTAR Superconducting Coils
    Park, Y. M.
    Lee, H. J.
    Lee, Y. J.
    Park, S. H.
    Kwag, S. W.
    Song, N. H.
    Chang, Y. B.
    Park, H. T.
    Woo, I. S.
    Bang, E. N.
    Kim, Y. S.
    Yang, H. L.
    Bak, J. S.
    Kwon, M.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 530 - 533
  • [4] AC LOSSES IN SUPERCONDUCTING MAGNETS AT LOW EXCITATION-LEVELS
    HUNT, TK
    JOURNAL OF APPLIED PHYSICS, 1974, 45 (02) : 907 - 913
  • [5] AC LOSSES IN SUPERCONDUCTING SYNCHROTRON MAGNETS
    BRECHNA, H
    RIES, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1971, NS18 (03) : 639 - &
  • [6] Ac losses of superconducting accelerator magnets
    Kovachev, V
    MODERN PHYSICS LETTERS B, 2003, 17 (5-6): : 175 - 198
  • [7] LOSS AND MAGNETIZATION MEASUREMENT OF SUPERCONDUCTING MAGNETS PULSED AT VERY LOW RAMP RATES
    GOMORY, F
    CESNAK, L
    CRYOGENICS, 1985, 25 (07) : 375 - 380
  • [8] LOSSES IN SUPERCONDUCTING MAGNETS UNDER FAST RAMP RATE OPERATION
    ITO, D
    NAKAYAMA, Y
    OGASAWARA, T
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) : 971 - 974
  • [9] Thermal-hydraulic analysis on KSTAR superconducting magnets
    Wang, QL
    Kim, M
    Kim, K
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 449 - 452
  • [10] Simulation of dynamic stress in PF superconducting magnets for KSTAR under normal operating conditions
    Wang, QL
    Yoon, CS
    Baang, S
    Kim, K
    Chung, W
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 1488 - 1491