Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols

被引:0
|
作者
Ajan, Aida [1 ,2 ,5 ]
Roberg, Karin [2 ,3 ]
Fredriksson, Ingemar [4 ]
Abtahi, Jahan [1 ,2 ]
机构
[1] Linkoping Univ Hosp, Dept Oral & Maxillofacial Surg, Linkoping, Sweden
[2] Linkoping Univ, Dept Biomed & Clin Sci BKV, Linkoping, Sweden
[3] Dept Otorhinolaryngol Linkoping, Linkoping, Ostergotland, Sweden
[4] Linkoping Univ, Dept Biomed Engn IMT, Linkoping, Sweden
[5] Linkoping Univ Hosp, Dept Oral & Maxillofacial Surg, S-58185 Linkoping, Sweden
关键词
Laser Doppler Flowmetry; Microcirculation; Local heating; Thermoprobe; Methyl Nicotinate; BLOOD-FLOW; METHYL NICOTINATE; SKIN; VASODILATATION; PERFUSION; SNUFF;
D O I
10.1016/j.mvr.2024.104666
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva. Methods: Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 degrees C, 3; LDF with thermoprobe 45 degrees C, 4; LDF with thermoprobe 42 degrees C and MN, 5; LDF with thermoprobe 45 C and MN and 6; LDF with MN. Results: Intra-individual reproducibility was assessed by the within -subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9-10.3 and ICC 0.82-0.93. The topically applied MN yielded increased blood flow. Conclusion: This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Gingival microcirculation response to tooth brushing measured by Laser Doppler Flowmetry
    Perry, DA
    McDowell, JA
    Goodis, HE
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1418 - 1418
  • [2] Gingival microcirculation response to tooth brushing measured by laser Doppler flowmetry
    Perry, DA
    McDowell, J
    Goodis, HE
    [J]. JOURNAL OF PERIODONTOLOGY, 1997, 68 (10) : 990 - 995
  • [3] Assesment of gingival microcirculation in anterior teeth using laser Doppler flowmetry
    Canjau, Silvana
    Miron, Mariana I.
    Todea, Carmen D.
    [J]. HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [4] Reproducibility of transcutaneous oximetry and laser Doppler flowmetry in facial skin and gingival tissue
    Svalestad, J.
    Hellem, S.
    Vaagbo, G.
    Irgens, A.
    Thorsen, E.
    [J]. MICROVASCULAR RESEARCH, 2010, 79 (01) : 29 - 33
  • [5] Laser Doppler flowmetry in the study of feet skin microcirculation in IDDM
    Taton, J
    Czech, A
    Buraczewska, B
    [J]. DIABETOLOGIA, 1999, 42 : A306 - A306
  • [6] Identification of Gingival Microcirculation Using Laser Doppler Flowmetry in Patients with Orthodontic Treatment-A Longitudinal Pilot Study
    Laredo-Naranjo, Martha Alicia
    Patino-Marin, Nuria
    Martinez-Castanon, Gabriel Alejandro
    Medina-Solis, Carlo Eduardo
    Velazquez-Hernandez, Carolina
    Nino-Martinez, Nereyda
    Orozco, Marco Felipe Salas
    [J]. MEDICINA-LITHUANIA, 2021, 57 (10):
  • [7] Laser Doppler flowmetry to assess myocardial microcirculation
    Piotrowski, Jakub
    Anisimowicz, Lech
    Hellmann, Marcin
    [J]. CARDIOLOGY JOURNAL, 2020, 27 (02) : 197 - 199
  • [8] LASER DOPPLER FLOWMETRY FOR THE ASSESSMENT OF THE CEREBRAL MICROCIRCULATION
    ELLIS, EF
    HEIZER, ML
    ZHANG, X
    MARMAROU, A
    HABERL, R
    [J]. FASEB JOURNAL, 1988, 2 (04): : A507 - A507
  • [9] LASER DOPPLER FLOWMETRY - MUSCULAR MICROCIRCULATION IN ANESTHESTIZED HORSES
    SERTEYN, D
    MOTTART, E
    MICHAUX, C
    MICHEELS, J
    PHILIPPART, C
    LAVERGNE, L
    GUILLON, C
    LAMY, M
    [J]. EQUINE VETERINARY JOURNAL, 1986, 18 (05) : 391 - 395
  • [10] EVALUATION OF GINGIVAL VASCULARISATION USING LASER DOPPLER FLOWMETRY
    Vitez, B.
    Todea, C.
    Velescu, A.
    Sipos, C.
    [J]. HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670