Vortex-assisted dispersive liquid-liquid microextraction based on the hydrophobic deep eutectic solvent-based ferrofluid for extraction and detection of myclobutanil

被引:5
|
作者
Na, Yue [1 ]
Gao, Xun [2 ]
Hong, Jiawei [1 ]
Zhou, Xunyong [3 ]
Liang, Ning [4 ]
Zhao, Longshan [1 ]
机构
[1] Shenyang Pharmaceut Univ, Sch Pharm, 103 Wenhua Rd, Shenyang 110016, Liaoning, Peoples R China
[2] Jiangsu Ocean Univ, Coinnovat Ctr Jiangsu Marine Bioind Technol, Lianyungang 222001, Peoples R China
[3] HC Enzyme Biotech Co Ltd, Shenzhen 518001, Guangdong, Peoples R China
[4] Shenyang Pharmaceut Univ, Sch Pharmaceut Engn, Shenyang 110016, Liaoning, Peoples R China
关键词
High-performance liquid chromatography-diode array detector; Magnetic nanoparticles; Box-Behnken design; Triazole fungicide; Fruit juice; TRIAZOLE FUNGICIDES; GAS-CHROMATOGRAPHY; DEGRADATION; TOXICITY; SOIL;
D O I
10.1007/s00604-023-05884-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A vortex-assisted dispersive liquid-liquid microextraction (VA-DLLME) procedure using hydrophobic deep eutectic solvent-based ferrofluid ( HDES-FF) as an extractant was established. The developed sample preparation method coupled with high-performance liquid chromatography-diode array detector (HPLC-DAD) was applied to the pretreatment and determination of myclobutanil (MYC) in fruit juice. Hydrophobic deep eutectic solvent, synthesized by n-decanoic acid and DL-menthol, was as a carrier and combined with magnetic nanoparticles (Fe3O4@OA) to form HDES-FF as an extractant with high extraction capacity. The synthesized materials were characterized by Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), and vibrating sample magnetometer (VSM). Parameters affecting extraction efficiency were optimized using single-factor experiments and Box- Behnken design via response surface methodology (BBD-RSM). Parallel tests were performed three times under the optimal conditions predicted by the model, yielding an actual mean recovery of 94.77% with RSD of 2.7% (n = 3) and an enrichment factor of 41.8 +/- 0.98 (mean value +/- SD, n = 3). Under the optimal conditions, the linear range was 1.0-100.0 mu g center dot mL(-1); the limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.80 mu g center dot mL(-1), respectively. The average spiked recoveries in the samples ranged from 98.2 to 100.5% with intra- day relative standard deviations (RSDs) of 1.2-3.5% (n = 3) and inter-day RSDs of 1.1-3.8% (n = 3). Finally, the method was successfully applied to the determination of MYC antimicrobial agent in different fruit juice samples. The proposed HDES-FF-VA-DLLME/HPLC-DAD method was verified to widely apply to the extraction of triazole fungicides.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Vortex-assisted dispersive liquid–liquid microextraction based on the hydrophobic deep eutectic solvent–based ferrofluid for extraction and detection of myclobutanil
    Yue Na
    Xun Gao
    Jiawei Hong
    Xunyong Zhou
    Ning Liang
    Longshan Zhao
    Microchimica Acta, 2023, 190
  • [2] A hydrophobic deep eutectic solvent-based vortex-assisted dispersive liquid-liquid microextraction combined with HPLC for the determination of nitrite in water and biological samples
    Zhang, Kaige
    Li, Shuangying
    Liu, Chuang
    Wang, Qi
    Wang, Yunhe
    Fan, Jing
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (02) : 574 - 581
  • [3] Deep eutectic solvent-based dispersive liquid-liquid microextraction
    Farajzadeh, Mir Ali
    Mogaddam, Mohammad Reza Afshar
    Aghanassab, Mahdi
    ANALYTICAL METHODS, 2016, 8 (12) : 2576 - 2583
  • [4] A Vortex-Assisted Deep Eutectic Solvent-Based Liquid-Liquid Microextraction for the Analysis of Alkyl Gallates in Vegetable Oils
    Cabuk, Hasan
    Yilmaz, Yasemin
    Yildiz, Elif
    ACTA CHIMICA SLOVENICA, 2019, 66 (02) : 385 - 394
  • [5] Deep eutectic solvent-based ferrofluid for vortex-assisted liquid-liquid microextraction of nonsteroidal anti-inflammatory drugs from environmental waters
    Yildirim, Sercan
    Karabulut, Sema Nur
    Cicek, Muekafat
    Horstkotte, Burkhard
    TALANTA, 2024, 268
  • [6] A hydrophobic deep eutectic solvent-based vortex-assisted liquid-liquid microextraction applied for doping control of aromatase inhibitors from equine urine
    Chen, Qian
    Wang, Zhao
    Chen, Huaixia
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 234
  • [7] Hydrophobic deep eutectic solvent-based vortex-assisted dispersive liquid-liquid microextraction with UV-visible spectrophotometry for copper determination in waste printed circuit boards
    Dilip, Yadav
    Laxman, Parhad
    Suhas, Janwadkar
    Arundhati, Nighojkar
    Mrunmayi, Churi
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [8] Optimization of vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction for quantification of niclosamide in real samples
    Altunay, Nail
    Ul Haq, Hameed
    Castro-Munoz, Roberto
    FOOD CHEMISTRY, 2023, 426
  • [9] Sensitive determination of vincristine in plasma of children with leukaemia using vortex-assisted dispersive liquid-liquid microextraction based on hydrophobic deep eutectic solvent
    Golpayegani, Mohammad Reza
    Akramipour, Reza
    Gheini, Simin
    Amini, Mazyar Vakili
    Fattahi, Farshad
    Mohebbi, Ali
    Fattahi, Nazir
    RSC ADVANCES, 2022, 12 (06) : 3611 - 3617
  • [10] Deep Eutectic Solvent-based Vortex-assisted Dispersive Liquid-liquid Microextraction Combined with High Performance Liquid Chromatography for the Determination of Phenolic Acids in Vegetable Oils
    Jing, Xu
    Cao, Chenyang
    Wu, Wenying
    Zhao, Wenfei
    Wang, Yu