Detailed Thermo-Economic Assessment of a Heat Pump for Industrial Applications

被引:2
|
作者
Martinez-Rodriguez, Guillermo [1 ]
Diaz-de-Leon, Cristobal [1 ]
Fuentes-Silva, Amanda L. [1 ]
Baltazar, Juan-Carlos [2 ]
Garcia-Gutierrez, Rafael [3 ]
机构
[1] Univ Guanajuato, Dept Chem Engn, Noria Alta S-N, Guanajuato 36050, Mexico
[2] Texas A&M Univ, Energy Syst Lab, Texas A&M Engn Expt Stn TEES, 3581 TAMU, College Stn, TX 77843 USA
[3] Univ Sonora UNISON, Dept Invest Fis, Hermosillo 83000, Sonora, Mexico
关键词
heat pump; low temperature heat source; thermo-economic assessment; coefficient of performance; refrigerant R-1234ze (E); evaporator temperatures; operating conditions; renewable energy; SOLAR; REFRIGERANTS; COST;
D O I
10.3390/en16062784
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Heat pump electricity costs grow with a power relationship as the evaporator temperature in the cycle decreases. The thermo-economic study of a solar thermal-assisted heat pump and storage system determines the minimum cost of the coupled system for an evaporator temperature. Through two case studies, one for the dairy industry and the other for 2G bioethanol production, the coupled system was evaluated for different temperatures in the evaporator, from 30 to 90 degrees C, and the minimum cost of the coupled system was determined. For the dairy industry, the lowest levelized total cost of a heat pump (LCOE) at 50 degrees C is 0.0799 USD/kWh. The evaluation carried out allowed us to determine the best operating conditions of the heat pump: 50 degrees C in the evaporator, COP = 4.2, and the work of the compressor of 211.3 kW. In the case of 2G anhydrous bioethanol production, the lowest levelized energy cost is 0.0409 USD/kWh for an evaporator temperature of 30 degrees C and a payback of 1.8 years. The study carried out makes it possible to guarantee the supply of the heat load at the operating temperature of the process and determines the impact of environmental conditions on the cost of the heat pump assisted with solar thermal energy.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Thermo-Economic Analysis of an Air-to-Water Heat Pump
    Popa, Viorel
    Ion, Ion
    Popa, Camelia Lacramioara
    EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 : 408 - 415
  • [2] Thermo-economic analysis of solar powered adsorption heat pump
    Lambert, Michael A.
    Beyene, Asfaw
    APPLIED THERMAL ENGINEERING, 2007, 27 (8-9) : 1593 - 1611
  • [3] Thermo-Economic Assessment of a olive pomace Gasifier for Cogeneration Applications
    Borello, Domenico
    De Caprariis, Benedetta
    De Filippis, Paolo
    Di Carlo, Andrea
    Marchegiani, Andrea
    Pantaleo, Antonio Marco
    Shah, Nilay
    Venturini, Paolo
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 252 - 258
  • [4] Thermo-economic analysis of composite district heating substation with absorption heat pump
    Wu, Zhangxiang
    Wang, Yaran
    You, Shijun
    Zhang, Huan
    Zheng, Xuejing
    Guo, Jin
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2020, 166
  • [5] Thermo-economic design optimization of parabolic trough solar plants for industrial process heat applications with memetic algorithms
    Silva, R.
    Berenguel, M.
    Perez, M.
    Fernandez-Garcia, A.
    APPLIED ENERGY, 2014, 113 : 603 - 614
  • [6] Thermo-Economic Assessment Tool for Industrial Milk Spray Dryer Exhaust Heat Recovery Systems with Particulate Fouling
    Walmsley, Timothy G.
    Walmsley, Michael R. W.
    Atkins, Martin J.
    Neale, James R.
    PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 : 1459 - 1464
  • [7] Thermo-economic analysis of working fluids for a ground source heat pump for domestic uses
    Pishkariahmadabad, Mohammadreza
    Ayed, Hamdi
    Xia, Wei-Feng
    Aryanfar, Yashar
    Almutlaq, Abdulaziz M.
    Bouallegue, Belgacem
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [8] Thermo-economic and thermodynamic analysis and optimization of a two-stage irreversible heat pump
    Sahraie, Hamed
    Mirani, Mohammad Reza
    Ahmadi, Mohammad Hossein
    Ashouri, Milad
    ENERGY CONVERSION AND MANAGEMENT, 2015, 99 : 81 - 91
  • [9] Thermo-economic analysis of regenerative heat engines
    Bandyopadhyay, S
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2004, 42 (01) : 31 - 37
  • [10] Thermo-economic assessments on building heating by a sewage source heat pump coupled with heat storage system
    Ma, Jinxing
    Zhang, Xiaogang
    Yu, Jiabang
    Wei, Pan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53