AneuGuide™ software-assisted vs. manual measurements in sizing for pipeline embolization device: An agreement study

被引:2
|
作者
Lv, Bin [1 ]
Sun, Mingguang [2 ]
Shan, Yejie [3 ]
Cao, Xiangyu [1 ]
Du, Zhihua [1 ]
Liu, Xinfeng [1 ]
Zhang, Rongju [1 ]
Leng, Xiaochang [3 ]
Fiehler, Jens [4 ]
Siddiqui, Adnan H. [5 ,6 ]
Xiang, Jianping [3 ,8 ]
Wang, Jun [1 ,7 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Neurol, Beijing, Peoples R China
[2] Beijing Univ Chinese Med, Beijing Hosp Integrated Tradit Chinese & Western M, Dept Neurol, Beijing, Peoples R China
[3] ArteryFlow Technol Co Ltd, Hangzhou, Peoples R China
[4] Univ Med Ctr Hamburg Eppendorf, Dept Neuroradiol, Hamburg, Germany
[5] SUNY Buffalo, Jacobs Sch Med & Biomed Sci, Neurosurg & Radiol, Buffalo, NY USA
[6] SUNY Buffalo, Canon Stroke & Vasc Res Ctr, Jacobs Sch Med & Biomed Sci, Buffalo, NY USA
[7] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Neurol, 28 Fuxing Rd, Beijing 100853, Peoples R China
[8] ArteryFlow Technol Co Ltd, 459 Qianmo Rd, Hangzhou 310051, Peoples R China
关键词
Sizing; Flow diverter; Foreshortening; Pipeline embolization device; AneuGuide (TM) software; ANEURYSMS; OCCLUSION;
D O I
10.1016/j.compbiomed.2023.107715
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Sizing of flow diverters (FDs) is a challenging task in the treatment of intracranial aneurysms due to their foreshortening behavior. The purpose of this study is to evaluate the difference between the sizing results from the AneuGuide (TM) software and from conventional 2D measurement. Ninety-eight consecutive patients undergoing pipeline embolization device (PED) treatment between October 2018 and April 2023 in the First Medical Center of Chinese PLA General Hospital (Beijing, China) were retrospectively analyzed. For all cases, the optimal PED dimensions were both manually determined through 2D measurements on pre-treatment 3D-DSA and computed by AneuGuide (TM) software. The inter-rater reliability between the two sets of sizing results for each methodology was analyzed using intraclass correlation coefficient (ICC). The degree of agreement between manual sizing and software sizing were analyzed with the Bland-Altman plot and Pearson's test. Differences between two methodologies were analyzed with Wilcoxon signed rank test. Statistical significance was defined as p < 0.05. There was better inter-rater reliability between AneuGuide (TM) measurements both for diameter (ICC 0.92, 95%CI 0.88-0.95) and length (ICC 0.93, 95%CI 0.89-0.96). Bland-Altman plots showed a good agreement for diameter selection between two methodologies. However, the median length proposed by software group was significantly shorter (16 mm versus 20 mm, p < 0.001). No difference was found for median diameter (4.25 mm versus 4.25 mm). We demonstrated that the AneuGuide (TM) software provides highly reliable results of PED sizing compared with manual measurement, with a shorter stent length. AneuGuide (TM) may aid neurointerventionalists in selecting optimal dimensions for FD treatment.
引用
收藏
页数:9
相关论文
共 15 条
  • [1] Hematology-led, software-assisted warfarin dosing vs. manual dosing in hemodialysis patients
    Ward, Frank
    Clince, Michelle
    Hayes, Mary
    O'Shea, Susan
    HEMODIALYSIS INTERNATIONAL, 2021, 25 (01) : 140 - 141
  • [2] Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study
    Ospel, J. M.
    Gascou, G.
    Costalat, V.
    Piergallini, L.
    Blackham, K. A.
    Zumofen, D. W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (03) : 524 - 530
  • [3] Software-assisted quantitative analysis of small bowel motility compared to manual measurements
    Bickelhaupt, S.
    Froehlich, J. M.
    Cattin, R.
    Raible, S.
    Bouquet, H.
    Bill, U.
    Patak, M. A.
    CLINICAL RADIOLOGY, 2014, 69 (04) : 363 - 371
  • [4] Banff scoring of kidney allograft biopsies: "Manual" application vs software-assisted sign-out
    Demetris, Anthony J.
    Lesniak, Andrew J.
    Popp, Benjamin A.
    Frencho, Ronald J.
    Minervini, Marta, I
    Nalesnik, Michael A.
    El Hag, Mohamed, I
    Hariharan, Sundaram
    Randhawa, Parmjeet S.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2024, 161 (06) : 543 - 552
  • [5] Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients
    Syarif, A. N.
    Bangun, K.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [6] Efficacy of pipeline embolization device vs. traditional coils in embolization of intracranial aneurysms: A systematic review and meta-analysis
    Li, Wei
    Xiao, Zaixing
    Zhao, Kaixuan
    Yang, Shijie
    Zhang, Yichuan
    Li, Bin
    Zhou, Yu
    Ma, Yong
    Chai, Erqing
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [7] Safety and efficacy of the pipeline embolization device for treatment of small vs. large aneurysms: a systematic review and meta-analysis
    Ghaith, Abdul Karim
    Greco, Elena
    Rios-Zermeno, Jorge
    El-Hajj, Victor Gabriel
    Perez-Vega, Carlos
    Ghanem, Marc
    Kashyap, Samir
    Fox, W. Christopher
    Huynh, Thien J.
    Sandhu, Sukhwinder S.
    Ohlsson, Marcus
    Elmi-Terander, Adrian
    Bendok, Bernard R.
    Bydon, Mohamad
    Tawk, Rabih G.
    NEUROSURGICAL REVIEW, 2023, 46 (01)
  • [8] Safety and efficacy of the pipeline embolization device for treatment of small vs. large aneurysms: a systematic review and meta-analysis
    Abdul Karim Ghaith
    Elena Greco
    Jorge Rios-Zermeno
    Victor Gabriel El-Hajj
    Carlos Perez-Vega
    Marc Ghanem
    Samir Kashyap
    W. Christopher Fox
    Thien J. Huynh
    Sukhwinder S. Sandhu
    Marcus Ohlsson
    Adrian Elmi-Terander
    Bernard R. Bendok
    Mohamad Bydon
    Rabih G. Tawk
    Neurosurgical Review, 46
  • [9] Comparison of Stent-Assisted Coil Embolization and the Pipeline Embolization Device for Endovascular Treatment of Ophthalmic Segment Aneurysms: A Multicenter Cohort Study
    Adeeb, Nimer
    Griessenauer, Christoph J.
    Foreman, Paul M.
    Moore, Justin M.
    Motiei-Langroudi, Rouzbeh
    Chua, Michelle H.
    Gupta, Raghav
    Patel, Apar S.
    Harrigan, Mark R.
    Alturki, Abdulrahman Y.
    Ogilvy, Christopher S.
    Thomas, Ajith J.
    WORLD NEUROSURGERY, 2017, 105 : 206 - 212
  • [10] Performance of visual vs. software-assisted photo-identification in mark-recapture studies: a case study examining different life stages of the Pacific Horned Frog (Ceratophrys stolzmanni)
    Bardier, Cecilia
    Szekely, Diana
    Augusto-Alves, Guilherme
    Matinez-Latorraca, Nicolas
    Schmidt, Benedikt R.
    Cruickshank, Sam S.
    AMPHIBIA-REPTILIA, 2021, 42 (01) : 17 - 28