Left atrial strain is a good predictor of atrio-ventricular synchrony in leadless pacemaker pacing

被引:1
|
作者
Troisi, Federica [1 ,3 ]
Caccavo, Vincenzo P. [1 ]
Santobuono, Vincenzo E. [2 ]
Sgarra, Luca [1 ]
Carella, Maria C. [2 ]
Basile, Paolo [2 ]
Guaricci, Andrea I. [2 ]
Grimaldi, Massimo [1 ]
机构
[1] Reg Gen Hosp F Miulli, Cardiol Dept, Bari, Italy
[2] Univ Bari Aldo Moro, Interdisciplinary Dept Med, Cardiol Unit Polyclin Bari, Bari, Italy
[3] Reg Gen Hosp F Miulli, Cardiol Dept, I-70021 Bari, Italy
关键词
3-axis accelerometer; atrio-ventricular synchrony; left atrial echocardiographic assessment; left atrial strain;
D O I
10.1111/jce.16140
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe importance of atrio-ventricular synchrony pacing in sinus rhythm patients is known. To identify patients in whom leadless pacemakers are able to guarantee this atrio-ventricular synchrony, we explored correlations among echocardiographic measures of left atrial (LA) size and function (doppler parameter and strain) with A4 amplitude in patients implanted with new generation Micra-AV device.MethodsAfter implantation with Micra-AV system, patients underwent device interrogation to evaluate AV synchrony based on the sensing of atrial mechanics and echocardiographic exam to assess LA morphology and LA function.ResultsIn the 21 studied patients (14 males, 72 +/- 13 years), the A4 wave amplitude values inversely correlated with LA antero-posterior diameter, LA volume, LA contraction strain and LA conduit strain, while they were positively related with LA reservoir strain.DiscussionOur results indicate a statistically significant relationship between morphological echocardiographic LA parameters and atrial contraction signal (A4), detected by leadless pacemakers and used to synchronize ventricular pacing with the atrium. Instantaneous LA function assessment obtained with LA strain provides incremental information over morphological parameters. LA strain evaluates atrial myocardial deformation during the whole cardiac cycle. We found higher value of A4 in patients that have grater absolute value of LAsr, LAscd and LAsct, that are simple and measurable parameters of LA functional capacity.ConclusionPreimplant echocardiographic evaluation of the atrial contractility may be useful in predicting adequate A4 sensing and consequently a good atrio-ventricular synchrony pacing. Echocardiography LA strain study seems promising in Micra-AV patient selection.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 50 条
  • [1] Left atrial, ventricular and atrio-ventricular strain in patients with subclinical heart dysfunction
    Matteo Cameli
    Giulia Elena Mandoli
    Edoardo Lisi
    Aladino Ibrahim
    Eufemia Incampo
    Gianluigi Buccoliero
    Cosimo Rizzo
    Fiorella Devito
    Marco Matteo Ciccone
    Sergio Mondillo
    The International Journal of Cardiovascular Imaging, 2019, 35 : 249 - 258
  • [2] Left atrial, ventricular and atrio-ventricular strain in patients with subclinical heart dysfunction
    Cameli, Matteo
    Mandoli, Giulia Elena
    Lisi, Edoardo
    Ibrahim, Aladino
    Incampo, Eufemia
    Buccoliero, Gianluigi
    Rizzo, Cosimo
    Devito, Fiorella
    Ciccone, Marco Matteo
    Mondillo, Sergio
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (02): : 249 - 258
  • [3] Atrio-ventricular synchronous pacing with a single chamber leadless pacemaker: Programming and trouble shooting for common clinical scenarios
    El-Chami, Mikhael F.
    Bhatia, Neal K.
    Merchant, Faisal M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 533 - 539
  • [4] ATRIO-VENTRICULAR BLOCK INDUCED BY RIGHT ATRIAL PACING
    RUSKIN, J
    HARLEY, A
    GREENFIELD, JC
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1968, 256 (03): : 195 - +
  • [5] Right atrio-ventricular strain as a predictor of death in left-sided heart failure
    Vijiiac, A. E.
    Scarlatescu, A.
    Petre, I
    Onciul, S.
    Vatasescu, R.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [6] ATRIO-VENTRICULAR PACING IN HEART BLOCK
    LEINBACH, RC
    CHAMBERL.DA
    KASTOR, JA
    HARTHORN.JW
    SANDERS, CA
    CIRCULATION, 1968, 38 (4S6) : V125 - &
  • [7] Atrio-ventricular block during left atrial flutter ablation
    Zoppo, Franco
    Bertaglia, Emanuele
    Brandolino, Glauco
    Zerbo, Francesca
    D'Este, Daniele
    Pascotto, Pietro
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (07): : 921 - 924
  • [8] Determination of left ventricular function by atrio-ventricular pacing delay and left ventricular pacing site during acute myocardial ischemia
    Sinha, A. M.
    Sinha, D.
    Hu, K.
    Ritscher, G.
    Brachmann, J.
    Ertl, G.
    EUROPEAN HEART JOURNAL, 2008, 29 : 4 - 4
  • [9] Single-chamber leadless pacemaker for atrial synchronous or ventricular pacing
    Hai, Jo-Jo
    Chan, Yap-Hang
    Lau, Chu-Pak
    Tse, Hung-Fat
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (12): : 1438 - 1450
  • [10] Deterioration of left ventricular function following atrio-ventricular node ablation and right ventricular apical pacing in patients with permanent atrial fibrillation
    Szili-Torok, T
    Kimman, GP
    Theuns, D
    Poldermans, D
    Roelandt, JRTC
    Jordaens, LJ
    EUROPACE, 2002, 4 (01): : 61 - 65