Dosimetric quantities and cell survival for spatially fractionated radiation therapy

被引:10
|
作者
Ahmed, Mabroor [1 ,2 ,3 ]
Bicher, Sandra [1 ,2 ]
Stewart, Robert D. [4 ]
Bartzsch, Stefan [1 ,2 ]
Schmid, Thomas E. [1 ,2 ]
Combs, Stephanie E. [1 ,2 ]
Meyer, Juergen [4 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Radiat Oncol, Klinikum Rechts Isar, Munich, Germany
[2] Helmholtz Zentrum Munchen GmbH, Inst Radiat Med, German Res Ctr Environm Hlth, Neuherberg, Germany
[3] Tech Univ Munich, Phys Dept, Garching, Germany
[4] Univ Washington, Fred Hutchinson Canc Ctr, Dept Radiat Oncol, Seattle, WA 98195 USA
关键词
microbeam; minibeam; Equivalent Uniform Dose (EUD); biological dose; Relative Effectiveness Factor (REF); Spatially Fractionated Radiation Therapy (SFRT); Microbeam Radiation Therapy (MRT); relative biological effectiveness (RBE); RADIOTHERAPY; TOLERANCE; BOOTSTRAP; BEAMS;
D O I
10.3389/fphy.2022.1064860
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Purpose: Spatially Fractionated Radiation Therapy (SFRT) is characterized by large differences in peak and valley doses. Preclinical and clinical studies suggest that differences in biological mechanisms lead to differential normal tissue and tumor response compared to uniform irradiation. We hypothesize that to evaluate clinical effectiveness and understand fundamental biological mechanisms, radiobiological rather than physical dose quantities should be utilized for comparisons. The aim of this work is to determine whether Equivalent Uniform Dose (EUD) is a superior predictor of cell survival than absorbed dose. Methods: Absorbed dose parameters were compared to the Equivalent Uniform Dose to assess their predictive value for the relative effectiveness of uniform and SFRT with X-rays. A Bayesian bootstrap technique was utilized to model uncertainties in the biological fit parameters for a human fibroblast (MRC5) and two human tumor cell lines (LN18 and A549). Dose uncertainties were evaluated through measurements and error modeling of SFRT profiles. A dimensionless Relative Effectiveness Factor (REF) is proposed to quantify differences between uniform and SFRT irradiation. Results: For all cell lines, cell survival after SFRT matched uniform irradiation within the estimated uncertainties at equal values of the EUD. Average and peak dose showed poor correlation with in vitro cell survival. The proposed REF factor is dose dependent and suggests enhanced cell killing for both tumor cell lines (1.14 +/- .08 for LN18, 1.32 +/- .13 for A549 at 8 Gy EUD) for SFRT. Normal human fibroblasts showed reduced cell killing relative to uniform irradiation (.58 +/- .06 for MRC5). Synthetically generated SFRT dose profiles revealed that EUD uncertainties are dominated by valley dose uncertainties, especially at high doses. Discussion: EUD is more predictive of cell survival than average or valley dose. Valley dose is close to equal to the EUD for values > 10 Gy and has the advantage of being independent of uncertainties in biological parameters. The REF is a novel and useful metric to compare quantitative differences in SFRT and uniform irradiation. Conclusion: EUD is recommended for comparisons of SFRT and uniform irradiation. The results suggest an increase in survival of normal-human fibroblast cells and reduced survival for both tumor cell lines after SFRT relative to uniform irradiation.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Dosimetric Evalualtion of a Commercial Compensator for Spatially Fractionated Radiation Therapy
    Stathakis, S.
    Buckey, C.
    Guti, A. Rrez
    Mavroidis, P.
    Esquivel, C.
    Shi, C.
    Mihailidis, D.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] DOSIMETRIC EVALUATION OF A GRID COMPENSATOR FOR SPATIALLY FRACTIONATED RADIATION THERAPY
    Buckey, C.
    Stathakis, S.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S234 - S234
  • [3] Dosimetric Verification of the CCCS Algorithm for Spatially Fractionated Radiation Therapy
    Stathakis, S.
    Gutierrez, A.
    Mavroidis, P.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06) : 2888 - +
  • [4] A Dosimetric Study of Spatially Fractionated Radiation Therapy for Cell Culture and Small Animal Experiments
    Zhang, H.
    Pachipulusu, V.
    Han, H. R.
    Dang, N. P.
    Lukas, L.
    Epstein, A.
    MEDICAL PHYSICS, 2024, 51 (10) : 7977 - 7977
  • [5] DOSIMETRIC CHARACTERIZATION OF COLLIMATORS FOR SPATIALLY FRACTIONATED PROTON THERAPY OF THE EYE
    Tobola-Galus, Agata
    Swakon, Jan
    Olko, Pawel
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 351 - 354
  • [6] Dosimetric evaluation of parallel opposed spatially fractionated radiation therapy of deep-seated bulky tumors
    Meigooni, Ali S.
    Gnaster, Michael
    Dou, Kai
    Johnson, Ellis L.
    MEDICAL PHYSICS, 2007, 34 (02) : 599 - 603
  • [7] Divide and conquer: spatially fractionated radiation therapy
    Prezado, Yolanda
    EXPERT REVIEWS IN MOLECULAR MEDICINE, 2022, 24
  • [8] Dosimetry for Spatially Fractionated Synchrotron Radiation Therapy
    Livingstone, J.
    Adam, J. F.
    Stevenson, A. W.
    Hausermann, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E658 - E658
  • [9] Immune Priming with Spatially Fractionated Radiation Therapy
    Lukas, Lauren
    Zhang, Hualin
    Cheng, Karen
    Epstein, Alan
    CURRENT ONCOLOGY REPORTS, 2023, 25 (12) : 1483 - 1496
  • [10] Immune Priming with Spatially Fractionated Radiation Therapy
    Lauren Lukas
    Hualin Zhang
    Karen Cheng
    Alan Epstein
    Current Oncology Reports, 2023, 25 : 1483 - 1496