EFFECT OF FACET MATERIAL ON STRESS DISTRIBUTION IN DENTAL IMPLANTS

被引:0
|
作者
Sedmak, Aleksandar [1 ]
Milosevic, Milos [2 ]
Coli, Katarina [2 ]
Petrovi, Ivana [1 ]
机构
[1] Univ Belgrade, Fac Mech Engn, Belgrade, Serbia
[2] Univ Belgrade, Fac Mech Engn, Innovat Ctr, Belgrade, Serbia
关键词
stress distribution; dental implant; facet material; connected crowns; IMAGE CORRELATION-ANALYSIS; FINITE-ELEMENT-ANALYSIS; SUPPORTED PROSTHESES; INTEGRITY ASSESSMENT; NUMERICAL-ANALYSIS; LOAD-TRANSFER; DENTISTRY;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, an FEM model is used to analyse the effect of facet material on the load transfer from implant to bone, as one aspect of the broader research, including the effects of a different crown design (connected and separated), a different facet material (porcelain and resin), and different loading (force at one or two points), whereas the focus is on the facet material effect in the connected crown loaded at one point. Results indicate significant reduction of maxi-mum stress if the epoxy resin is used instead of porcelain.
引用
收藏
页码:363 / 366
页数:4
相关论文
共 50 条
  • [1] Effect of coating thickness and its material on the stress distribution for dental implants
    Production Engineering and Mechanical Design Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt
    J. Med. Eng. Technol., 2007, 4 (280-287):
  • [2] Effect of thread dimensions of functionally graded dental implants on stress distribution
    Celik, Nevin
    Kaman, Mete Onur
    CURRENT OPINION IN BIOTECHNOLOGY, 2013, 24 : S46 - S46
  • [3] On stress/strain shielding and the material stiffness paradigm for dental implants
    Korabi, Raoof
    Shemtov-Yona, Keren
    Rittel, Daniel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 935 - 943
  • [4] EFFECT OF ELASTIC-MODULUS AND TRABECULAR STRUCTURE ON STRESS DISTRIBUTION AROUND DENTAL IMPLANTS
    KLAWITTER, JJ
    COOK, SD
    WEINSTEIN, AM
    DAS, S
    JOURNAL OF DENTAL RESEARCH, 1979, 58 : 410 - 410
  • [5] Stress Distribution Around Dental Implants Placed at Different Depths
    Zanardi, Piero Rocha
    Stegun, Roberto Chaib
    Sesma, Newton
    Costa, Bruno
    Shibli, Jamil Awad
    Lagana, Dalva Cruz
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (07) : 2163 - 2166
  • [6] Effect of 3D Printing Material and Thickness on Stress Distribution of Dental Implant
    Chen, Weican
    Jiang, Si
    Shi, Shuo
    Li, Ye
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 50 - 50
  • [7] THE INFLUENCE OF IMPLANT GEOMETRY ON THE STRESS-DISTRIBUTION AROUND DENTAL IMPLANTS
    COOK, SD
    KLAWITTER, JJ
    WEINSTEIN, AM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (04): : 369 - 379
  • [8] The Influence of Cement Thickness within the Cap on Stress Distribution for Dental Implants
    Ceddia, Mario
    Romasco, Tea
    Comuzzi, Luca
    Cipollina, Alessandro
    Piattelli, Adriano
    Dipalma, Gianna
    Inchingolo, Angelo Michele
    Inchingolo, Francesco
    Di Pietro, Natalia
    Trentadue, Bartolomeo
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (07)
  • [9] STRESS-DISTRIBUTION AROUND DENTAL IMPLANTS - INFLUENCE OF SUPERSTRUCTURE, LENGTH OF IMPLANTS, AND HEIGHT OF MANDIBLE
    MEIJER, HJA
    KUIPER, JH
    STARMANS, FJM
    BOSMAN, F
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01): : 96 - 102
  • [10] STRESS DISTRIBUTION IN BONE ARISING FROM LOADING ON ENDOSTEAL DENTAL IMPLANTS
    TESK, JA
    WIDERA, O
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (03): : 251 - 261