Human response to the bed thermal environment generated by a ventilated mattress combined with local heating

被引:0
|
作者
Song, Ge [1 ,2 ]
Melikov, Arsen Krikor [3 ]
Zhang, Guoqiang [1 ,2 ]
Bivolarova, Mariya Petrova [3 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Natl Ctr Int Res Collaborat Bldg Safety & Environm, Beijing, Peoples R China
[3] Tech Univ Denmark, Dept Environm & Resource Engn, Lyngby, Denmark
关键词
Bed thermal environment; Room temperature; Ventilated mattress; Local heating; Human response; Control; PERFORMANCE EVALUATION; PARTICLE RESUSPENSION; AMBIENT-TEMPERATURES; BODY-TEMPERATURE; SLEEP QUALITY; AIR; COMFORT; IMPACT; CLIMATE; PILLOWS;
D O I
10.1016/j.buildenv.2023.110461
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A ventilated mattress (VM) was designed to withdraw the polluted air of the bed micro-environment through an opening located near the feet, moving the air inside the mattress to where it was cleaned and could be discharged back to the room or ducted out of the room. Thermal manikin experiments indicated a risk of uncomfortable local cooling of user's feet. The design of the VM was therefore improved by incorporating local heating (LH). The response of 30 subjects to the bed thermal environment (BTE) generated by the improved design was studied while they lay awake on the VM at room temperatures: 19 & DEG;C, 23 & DEG;C and 28 & DEG;C. Based on the subjects' responses the flow rate through the VM and the LH were adjusted to provide acceptable whole body and local thermal sensation. The surface temperature of the mattress, the air temperature and relative humidity in the BTE and the temperature and flow rate of the air exhausted through the VM were measured. The results show that the VM if used alone may cause unacceptable local body cooling at 19 & DEG;C and 23 & DEG;C, so some LH was required. At 28 & DEG;C the VM improved subjects' thermal comfort. Continuous control of the VM and the LH improved the acceptability of the BTE and decreased the risk of local discomfort. The surface temperature of the mattress measured near the feet correlated well with occupant's thermal sensation and could be used to control the operation of the VM fan speed and the LH.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Influence of local electric heating on overall thermal response of human body in cold environment
    Zhang Z.
    Chen X.
    Ni J.
    Yang Y.
    Zou Y.
    [J]. Fangzhi Xuebao/Journal of Textile Research, 2023, 44 (03): : 187 - 194
  • [3] Thermal model of an unconditioned, heated and ventilated seat to predict human thermo-physiological response and local thermal sensation
    Fojtlin, Milos
    Psikuta, Agnes
    Fiser, Jan
    Pokorny, Jan
    Toma, Robert
    Annaheim, Simon
    Jicha, Miroslav
    Rossi, Rene M.
    [J]. BUILDING AND ENVIRONMENT, 2020, 169
  • [4] RESPONSE OF HUMAN SWEAT GLANDS TO LOCAL HEATING
    MCLAUGHLIN, JT
    SONNENSCHEIN, RR
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1963, 41 (01) : 27 - 29
  • [5] Effects of local heating of body on human thermal sensation and thermal comfort
    Liu, Chao
    Tang, Yuanze
    Sun, Limei
    Zhang, Nan
    Gao, Weijun
    Yuan, Liyun
    Shi, Jing
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 53
  • [6] Thermal physiological response to local heating and cooling during sleep
    Hibino, Yu
    Hokoi, Shuichi
    Yoshida, Katsuaki
    Takada, Satoru
    Nakajima, Masanori
    Yamate, Miho
    [J]. FRONTIERS OF ARCHITECTURAL RESEARCH, 2012, 1 (01) : 51 - 57
  • [7] Thermal physiological response to local heating and cooling during sleep
    Yu Hibino
    Shuichi Hokoi
    Katsuaki Yoshida
    Satoru Takada
    Masanori Nakajima
    Miho Yamate
    [J]. Frontiers of Architectural Research, 2012, 1 (01) : 51 - 57
  • [8] Response of hydraulic pipes to combined excitation in thermal environment
    Gao, Si-Yu
    Mao, Xiao-Ye
    Ding, Hu
    Chen, Li-Qun
    [J]. NONLINEAR DYNAMICS, 2024, 112 (15) : 12795 - 12814
  • [9] Human response to combined indoor environment exposures
    Toftum, J
    [J]. ENERGY AND BUILDINGS, 2002, 34 (06) : 601 - 606
  • [10] Preferred local electrical heating and its effect on overall thermal response
    Chen, Xue
    Zhang, Zhaohua
    Yang, Yutong
    [J]. INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2023, 35 (04) : 526 - 544