Best Estimate Plus Uncertainty Analysis of Station Blackout Transient in Pool-Type Research Reactor

被引:0
|
作者
Mishra, Amitanshu [1 ]
Guchhait, Paban Kumar [1 ]
Sengupta, Samiran [1 ]
机构
[1] Bhabha Atom Res Ctr, CIRUS Complex, Trombay 400085, Mumbai, India
关键词
Best Estimate Plus Uncertainty; Latin hypercube sampling; RELAP5; station blackout; sensitivity analysis; Wilks formula; SIMULATION; SYSTEM;
D O I
10.1080/00295450.2024.2304915
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Simulation of a station blackout (SBO) scenario was carried out for an open pool-type nuclear research reactor. The SBO transient was analyzed using the best estimate (BE) thermal-hydraulic code RELAP5/MOD3.2 to evaluate the performance of safety systems and inherent thermal inertia provided by the reactor pool in ensuring adequate core cooling during a prolonged SBO condition lasting up to 7 days. This encompasses assessment of cooling provided by battery-operated auxiliary pumps in the initial phase followed by setup of the natural convection cooling mode for the extended period. Best Estimate Plus Uncertainty (BEPU) methodology was applied for assessment of safety margins. This involved estimation of required simulations using the Wilks first-order formulation to achieve results within the tolerance limit of 95/95. Identification of relevant uncertainties and their propagation was carried out; subsequently, a case matrix for 59 simulation runs was generated using the Latin hypercube sampling method. The upper/lower bounds of uncertainty results were analyzed and compared with the BE code results. Later, sensitivity analysis was carried out using sensitivity coefficients generated using the Pearson and Spearman coefficient. The results show that the values of the crucial thermal-hydraulic parameters obtained with the tolerance limit of 95/95 met the acceptance criteria, with adequate safety margins.
引用
下载
收藏
页码:1932 / 1951
页数:20
相关论文
共 50 条
  • [1] Accident analysis of station blackout of pool-type research reactor during high power operation
    Huang, Hong-Wen
    Liu, Han-Gang
    Qian, Da-Zhi
    Xu, Xian-Qi
    Hedongli Gongcheng/Nuclear Power Engineering, 2012, 33 (04): : 13 - 16
  • [2] Application of Best Estimate Plus Uncertainty in Review of Research Reactor Safety Analysis
    Adu, Simon
    Horvatovic, Ivan
    D'Auria, Francesco
    23RD INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2014), 2014,
  • [3] APPLICATION OF BEST ESTIMATE PLUS UNCERTAINTY IN REVIEW OF RESEARCH REACTOR SAFETY ANALYSIS
    Adu, Simon
    Horvatovic, Ivan
    Darko, Emmanuel O.
    Emi-Reynolds, Geoffrey
    D'Auria, Francesco
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2015, 30 (01): : 75 - 82
  • [4] Convective Cooling in a Pool-type Research Reactor
    Sipaun, Susan
    Usman, Shoaib
    INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2015 (INUSTEC2015), 2016, 1704
  • [5] ANALYSIS OF POOL-TYPE REACTOR NOISE
    VANUITERT, GC
    VANDAM, H
    PROGRESS IN NUCLEAR ENERGY, 1977, 1 (2-4) : 649 - 662
  • [6] Uncertainty assessment for loss of flow accident of a 5 MW pool-type research reactor
    Yum, Soo-been
    Park, Su-ki
    ANNALS OF NUCLEAR ENERGY, 2017, 109 : 22 - 29
  • [7] EMERGENCY CORE COOLING SYSTEM FOR A POOL-TYPE RESEARCH REACTOR
    MEEM, JL
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (01): : 432 - &
  • [8] BEST ESTIMATE PLUS UNCERTAINTY ANALYSIS OF LBLOCA FOR A PICKERING B CANDU REACTOR
    Blake, Larry
    Gavrus, George
    Vecchiarelli, Jack
    Stoklosa, J.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE - 2010 - VOL 1, PTS A-C, 2010, : 1463 - 1472
  • [9] RELIABILITY ASSESSMENT OF EMERGENCY EXHAUST SYSTEM IN A POOL-TYPE RESEARCH REACTOR
    KHAN, SA
    NUCLEAR ENGINEERING AND DESIGN, 1991, 131 (01) : 37 - 60
  • [10] Transient flow analysis of pool-type reactor coolant pump under flow coast-down
    Huang, Bin
    Liu, Yihan
    Pu, Kexin
    Lu, Shangxiang
    Wu, Dazhuan
    ANNALS OF NUCLEAR ENERGY, 2024, 202