EXPERIMENTAL COMPARISON OF ECO-FRIENDLY REFRIGERANT COUPLES R407C/R32/R600a (90/10 BY WT.%) AND R407C/R32 TO REVEAL THE GWP AND THERMODYNAMIC PROPERTIES

被引:0
|
作者
Al Kraim, Adel Mohmed [1 ]
Atas, Safak [1 ]
机构
[1] Karabuk Univ, Fac Technol, Dept Energy Syst Engn, Karabuk, Turkiye
关键词
mini cascade refrigeration system; coefficient of performance; eco-friendly refrigerant couples; GWP; R32; R600a; PERFORMANCE ANALYSIS; MIXTURE; SYSTEM; HFC; REPLACEMENT; ENERGY; R134A; R32;
D O I
10.1615/HeatTransRes.2022043993
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this experimental study, based on cooling couples a new mixture (90%R32 + 10%R600a) has been proven to be better than R32 for the global warming potential (GWP) in a low-pressure cycle (LPC), within a high-pressure cycle (HPC) R407C by utilizing a small laboratory cooling system. This system consists of two cooling cycles connected by a heat exchanger and has also been termed as a mini cascade refrigeration system (MCRS). The main aim of this study is to study a suitable gas or mixture for MCRS at the lowest GWP value and a low-temperature cooling room to reach less than -30?. In the same way, the following conditions have been determined in this research: the inlet and outlet temperatures of the evaporator, condenser, heat exchanger, compressors, with evaporator pressure as well as superheat. Consequently, MCRS can be used with thermostats at the lowest degree of -32? or less, the mixture has results close to R32 and the coefficient of performance for MCRS COPMCRS is equal to 1.63 and 1.78 for the new mixture and R32, respectively, under the same operating conditions. Therefore, the ozone depletion potentials (ODP) for R32 and the new mixture are equal to zero, and the GWP for the new mixture is less by amount of 63 than that for R32. The MCRS can be used in a small place, for instance, transport blood samples, blood tests, and vaccines by small cars. Both R32 and R600a are flammable gases, so this study will be carried on in the future for safer replacements.
引用
收藏
页码:73 / 94
页数:22
相关论文
共 50 条
  • [1] Study on the lubricants suitable for R32/R134a and R407C
    Zhao, Lei
    Zhao, Yuan-Xiao
    Liu, Xian-Ding
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture & Technology, 2002, 34 (03):
  • [2] Experimental study of ternary mixture R32/R125/R161 as alternative refrigerant to R407C
    Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
    Zhejiang Daxue Xuebao (Gongxue Ban), 2007, 2 (337-341):
  • [3] Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407C
    Han, X. H.
    Wang, Q.
    Zhu, Z. W.
    Chen, G. M.
    APPLIED THERMAL ENGINEERING, 2007, 27 (14-15) : 2559 - 2565
  • [4] R32/R134a和R407C用于变浓度热泵系统的实验
    张丽娜
    陈光明
    低温工程, 2009, (02) : 52 - 55
  • [5] 适用于R32/R134a及R407C的润滑油研究
    赵蕾
    赵原晓
    刘咸定
    西安建筑科技大学学报(自然科学版), 2002, (03) : 232 - 235
  • [6] Performance evaluation of a fin-and-tube evaporator with R407C/R290/R600a refrigerant mixture
    Raj, M. H.
    Lal, D. M.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2010, 31 (01) : 33 - 46
  • [7] A comparative study on the performance of a R22 window air conditioner retrofitted with R407C/R290/R600a refrigerant mixture
    Raj, M. H.
    Lal, D. M.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2008, 29 (04) : 207 - 217
  • [8] Condensation of refrigerant R407C in multiport minichannel section
    Bohdal, Tadeusz
    Charun, Henryk
    Sikora, Malgorzata
    ARCHIVES OF THERMODYNAMICS, 2016, 37 (04) : 3 - 18
  • [9] Study on frosting characteristics of an evaporator using R407C as refrigerant
    Zhang, SZ
    Chen, GM
    Wang, JF
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 269 - 273
  • [10] Determination of thermodynamic properties of an alternative refrigerant (R407c) using artificial neural network
    Sozen, Adnan
    Arcaklioglu, Erol
    Menlik, Tayfun
    Ozalp, Mehmet
    EXPERT SYSTEMS WITH APPLICATIONS, 2009, 36 (03) : 4346 - 4356