Correction of JET bolometric maximum likelihood tomography for local gas puffing

被引:1
|
作者
Peluso, Emmanuele [1 ]
Murari, Andrea [2 ,3 ]
Craciunescu, Teddy [4 ]
Carvalho, Pedro [5 ]
Gelfusa, Michela [1 ]
Gaudio, Pasqualino [1 ]
Wyss, Ivan [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Ind Engn, Via Politecn 1, I-00133 Rome, Italy
[2] Univ Padua, Consorzio RFX, ENEA, INFN,CNR,Acciaierie Venete SpA,Corso Stati, I-35127 Padua, Italy
[3] CNR, Ist Sci & Tecnol Plasmi, Padua, Italy
[4] Natl Inst Laser Plasma & Radiat Phys, RO-077125 Magurele, Romania
[5] Inst Super Tecn, Inst Plasmas & Fusao Nucl, P-1049001 Lisbon, Portugal
关键词
bolometry; tomography; maximum likelihood; nuclear fusion; turbulence and transport; optimization; NEUTRON; DIAGNOSTICS; EMISSION; SYSTEM;
D O I
10.1088/1361-6587/accd1c
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Tomography is applied daily to bolometric data in magnetically controlled nuclear fusion devices to infer important quantities of the studied plasmas, such as the emissivity profiles or the radiated power in different locations of the main chamber. Tomographic reconstructions are also crucial for power balance analysis and to estimate heat fluxes for turbulence studies. One of the issues, associated with any tomographic technique, resides in the ill-posed nature of the mathematical problem, meaning that more than one possible emissivity profile is compatible with the measurements within the estimated uncertainties. Therefore, a careful evaluation of the quality of the obtained reconstructions is an important step of the analysis. On Joint European Torus (JET), since the two cameras are located in different toroidal locations, axial symmetry of the plasma radiation must be assumed to perform traditional tomographic reconstructions. Such a specific hypothesis, however, cannot be guaranteed in the case of symmetry-breaking mechanisms, such as strong local gas puffing for fuelling. The present contribution addresses this problem of local plasma fuelling, focusing on the observed significant mismatch between measured and back-calculated projections in specific pulses, including the last JET DT campaign (DTE2) carried out in 2021. The analysis indicates that the observed discrepancy, due to the gas injected primarily from valves located in the same octant where one of the bolometer arrays is located, can be rectified acceptably well by a physically-based correction. The sensible improvements in the bolometric maximum likelihood tomography's outputs are also documented, and the possible physical explanation for such a phenomenon is discussed. The study performed in this article is expected to have a significant impact on the analysis of JET data and on the physical interpretation of the results obtained during the recent DTE2 experiments, for which a proper evaluation of the radiated power estimates is of non-negligible relevance.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A comprehensive study of the uncertainties in bolometric tomography on JET using the maximum likelihood method
    Peluso, E.
    Craciunescu, T.
    Murari, A.
    Carvalho, P.
    Gelfusa, M.
    Joffrin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (12):
  • [2] Maximum likelihood bolometric tomography for the determination of the uncertainties in the radiation emission on JET TOKAMAK
    Craciunescu, Teddy
    Peluso, Emmanuele
    Murari, Andrea
    Gelfusa, Michela
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arshad, S.
    Ash, A.
    Ashikawa, N.
    Aslanyan, V.
    Asunta, O.
    Auriemma, F.
    Austin, Y.
    Avotina, L.
    Axton, M. D.
    Ayres, C.
    Bacharis, M.
    Baciero, A.
    Baiao, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (05):
  • [3] Acceleration of an Algorithm Based on the Maximum Likelihood Bolometric Tomography for the Determination of Uncertainties in the Radiation Emission on JET Using Heterogeneous Platforms
    Ruiz, Mariano
    Nieto, Julian
    Costa, Victor
    Craciunescu, Teddy
    Peluso, Emmanuele
    Vega, Jesus
    Murari, Andrea
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [4] The maximum likelihood reconstruction method for JET neutron tomography
    Craciunescu, T.
    Bonheure, G.
    Kiptily, V.
    Murari, A.
    Soare, S.
    Tiseanu, I.
    Zoita, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (03): : 623 - 630
  • [5] LOCAL SOLUTIONS OF MAXIMUM LIKELIHOOD ESTIMATION IN QUANTUM STATE TOMOGRAPHY
    Goncalves, Douglas S.
    Gomes-Ruggiero, Marcia A.
    Lavor, Carlile
    Jimenez Farias, Osvaldo
    Souto Ribeiro, P. H.
    QUANTUM INFORMATION & COMPUTATION, 2012, 12 (9-10) : 775 - 790
  • [6] Methods of maximum likelihood tomography
    Hradil, Z
    Rehácek, J
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 669 - 678
  • [7] Evaluation of maximum-likelihood based attenuation correction in positron emission tomography
    Nuyts, J
    Dupont, P
    Stroobants, S
    Maes, A
    Mortelmans, L
    Suetens, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1136 - 1141
  • [8] Evaluation of maximum-likelihood based attenuation correction in positron emission tomography
    Nuyts, J.
    Dupont, P.
    Stroobants, S.
    Maes, A.
    Mortelmans, L.
    Suetens, P.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1836 - 1841
  • [9] Maximum likelihood iterative reconstruction for attenuation correction in positron emission tomography.
    Glatting, G
    Weller, R
    Reske, SN
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 181P - 182P
  • [10] Dealing with artefacts in JET iterative bolometric tomography using masks
    Peluso, Emmanuele
    Gelfusa, Michela
    Craciunescu, Teddy
    Martellucci, Luca
    Gaudio, Pasqualino
    Carvalho, Pedro
    Murari, Andrea
    PLASMA PHYSICS AND CONTROLLED FUSION, 2022, 64 (04)