Two-color pyrometry for backface temperature and emissivity measurement of burning materials

被引:7
|
作者
Pelzmann, Tanja [1 ]
Dupont, Fabien [2 ]
Saute, Benjamin [2 ]
Robert, Etienne [1 ]
机构
[1] Polytech Montreal, 2500 Chem Polytech, Montreal, PQ H3T 1J4, Canada
[2] Telops Inc, 100-2600 St Jean Baptiste Ave, Quebec City, PQ G2E 6J5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Emissivity change; Fire testing; Infrared imaging; Surface temperature measurement; Temperature emissivity separation; Thermal degradation; Thermography; IMPINGEMENT HEAT-TRANSFER; SPECTRAL EMISSIVITY; COMPOSITE-MATERIALS; FLUX MEASUREMENT; SYSTEM;
D O I
10.1016/j.ijthermalsci.2022.107894
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-color (2C) pyrometry has long been used for flame temperature and soot concentration studies and is now becoming more widely used to measure backface temperatures of burning materials. With the obvious advantage of being a contact-free method that requires only minimal optical access, 2C pyrometry combined with high-speed acquisition is a promising diagnostic tool to obtain exceptional temporal and spatial resolution of thermally degrading samples. However, its conceptual simplicity relies on a set of basic assumptions that when violated can result in large errors. In this work, we used an experimental configuration representative for fire resistance testing for aerospace and naval applications to analyze the impact of camera parameters and test setup on the accuracy of the surface temperature results obtained. Two types of fiber reinforced polymer composites and a steel plate are used to investigate material specific aspects that affect the measurements. An improved workflow for camera calibration is presented that takes into account the actual experimental setup. The temperature and emissivity mapping obtained through in-situ IR measurements is compared to data acquired through thermocouples and post-fire hemispherical directional reflectance measurements at room temperature. Excellent agreement is found for post-processed 2C pyrometry measurements and TC probe measurements with an uncertainty of 30 degrees C at 500 degrees C. In-situ emissivity mappings of burnt specimens are consistent with data from the literature for degraded composite samples and oxidized steel plates. Our results remind the importance of proper post-processing and demonstrate the potentials of 2C pyrometry for fire testing applications. We also present a detailed error budget and suggestions for calibration measurements to improve measurement accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Measurements of brake disc surface temperature and emissivity by two-color pyrometry
    Thevenet, Jean
    Siroux, Monica
    Desmet, Bernard
    APPLIED THERMAL ENGINEERING, 2010, 30 (6-7) : 753 - 759
  • [2] Measurement of surface temperature and emissivity of different materials by two-colour pyrometry
    Raj, Vinay C.
    Prabhu, S. V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (12):
  • [3] Two-Color Pyrometry Methods for Measuring the Surface Temperature of Materials Exposed to a Plasma Jet
    Sotnikova, G. Yu.
    Alexandrov, S. A.
    Voronin, A. V.
    Urzhumtsev, N. A.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2022, 67 (SUPPL 1) : S79 - S83
  • [4] Two-Color Pyrometry Methods for Measuring the Surface Temperature of Materials Exposed to a Plasma Jet
    G. Yu. Sotnikova
    S. A. Alexandrov
    A. V. Voronin
    N. A. Urzhumtsev
    Journal of Communications Technology and Electronics, 2022, 67 : S79 - S83
  • [5] Investigation of the Surface Temperature in Contact with Plasma by Two-Color Pyrometry
    Voronin, A. V.
    Goryainov, V. Yu.
    Kapralov, A. A.
    Tokarev, V. A.
    Sotnikova, G. Yu.
    TECHNICAL PHYSICS, 2023, 68 (12) : 799 - 805
  • [6] Investigation of the Surface Temperature in Contact with Plasma by Two-Color Pyrometry
    A. V. Voronin
    V. Yu. Goryainov
    A. A. Kapralov
    V. A. Tokarev
    G. Yu. Sotnikova
    Technical Physics, 2023, 68 : 799 - 805
  • [7] Applying two-color infrared pyrometry
    Lappe, Vern
    Sensors (Peterborough, NH), 1993, 10 (08): : 12 - 15
  • [8] Approximate two-color emission pyrometry
    Bhattacharjee, S
    King, M
    Cobb, W
    Altenkirch, RA
    Wakai, K
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 15 - 20
  • [9] Surface Temperature Measurement with Unknown Emissivity Using a Two-color Pyrometer Placed with a Reflector
    Che, Xunjian
    Xie, Zhi
    2017 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, AUTOMOTIVE AND MATERIALS ENGINEERING (CMAME), 2017, : 214 - 217
  • [10] Transient temperature measurement of electron beam bombarded stainless steel via nanosecond two-color pyrometry
    Watson, T. M.
    Mockert, J. T.
    Neuber, A. A.
    Dickens, J. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2025, 96 (02):